1. If either your hand or the Velcro strap is soaking wet, the Laser
beam may automatically light up without touch trigger. The scanner
can still work well in this condition but it will waste battery power,
so it is recommended to dry both your hand and the Velcro strap.
2. The following gloves have been tested to be working with the
touch-activated button: latex examination glove, antistatic glove,
white cotton glove (with or without latex coating), safety glove,
and rubber glove. However, it is still recommended to operate with
bare hand or thin glove to ensure the responsiveness of button.
3. Don’t need to tighten Velcro strap too much. Just make the strap fit
your finger so that the scanner will not easily move while being
touched for trigger. We also suggest to release the strap from your
finger for 1 minute after 2 hours of continuous use if your finger
feels uncomfortable.
-
9
-
-
10
-
Scan one of below configuration barcodes to determine your
interface:
STEP 3 - INTERFACE SELECTION
[ Recommended ]
. C006$
*.C006$*
USB VCP
. C008$
*.C008$*
USB HID
BT HID
. E043$
*.E043$*
Memory Mode
. C035$
*.c035$*
1.
BT HID, BT SPP
-
Emulates a
Bluetooth HID keyboard or
Bluetooth serial device,
please see next page for details.
4.
Memory Mode
-
Emulates a
USB mass storage device
that
collects barcode off-line, please see page 24 - 28 for details.
. F064$
*.F064$*
. F065$
*.F065$*
. F066$
*.F066$*
Scan one of below configuration barcodes to determine which
touch-sensing button to enable according to your habit:
STEP 2 - BUTTON PREFERENCE
Right Button Only
Left Button Only
Both Buttons
[ For Left-handed User ]
[ For Right-handed User ]
ATTENTION
. E042$
*.E042$*
BT SPP