background image

 

- 96 -

 

© 2018 unitech Electronics Co., Ltd. All rights reserved. 

unitech is a registered trademark of unitech Electronics Co., Ltd.

 

MS282 User’s Manual 

3.12.1 Set Lengths for Matrix 2 of 5 

The length of a code refers to the number of characters (i.e., human 
readable characters), including check digit(s) the code contains. Set 
lengths for Matrix 2 of 5 to any length, one or two discrete lengths, or 
lengths within a specific range. The default is One Discrete Length: 14. 

Note: When setting lengths, enter a leading zero for single digit numbers. 

 

Scan one of the following bar codes to select a length option: 

• 

One Discrete Length

 - Decode only Matrix 2 of 5 symbols containing a 

selected length. Select the length using the bar 
codes in 

Appendix B, Numeric Bar Codes

. For 

example, to decode only Matrix 2 of 5 symbols 
with 14 characters, scan Matrix 2 of 5 - One 
Discrete Length, and then scan 1, 4. To correct an 
error or change the selection, 

scan Cancel

• 

Two Discrete Lengths

 - Decode only Matrix 2 of 5 symbols containing 

either of two lengths. Select lengths using the bar 
codes in 

Appendix B, Numeric Bar Codes

. For 

example, to decode only Matrix 2 of 5 symbols 
containing either 2 or 14 characters, scan Matrix 
2 of 5 - Two Discrete Lengths, and then scan 0, 2, 
1, 4. To correct an error or change the selection,

 

scan Cancel

 Length Within Range 

- Decode Matrix 2 of 5 symbols with a specific 

length range. Select lengths using the bar codes 
in 

Appendix B, Numeric Bar Codes

. For example, 

to decode Matrix 2 of 5 symbols containing 
between 4 and 12 characters, scan Matrix 2 of 5 
- Length Within Range, and then scan 0, 4, 1, 2.   
To correct an error or change the selection, 

scan 

Cancel

Any Length - 

Decode Matrix 2 of 5 symbols containing any number of 

characters within the engine’s capability. 

 

 

 

Содержание MS282

Страница 1: ... 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd 2D Imager Barcode Scanner MS282 User s Manual Version 1 1 ...

Страница 2: ...lectronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd Change Log Date Change Description Version 2018 10 16 first published version 1 0 2018 12 05 Update Symbologies 1 1 ...

Страница 3: ...rt 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference with radio communications However there is no guarantee that interference will not occur in a...

Страница 4: ... to co channel Mobile Satellite Systems Therefore it will only transmit on the 5 25 5 35 GHz 5 47 5 725 GHz and 5 725 5 850 GHz band when associated with an access point AP FCC Label Statement This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received in...

Страница 5: ...health protection For body worn operation this device has been tested and meets the ICNIRP guidelines and the European Standard EN 62209 2 for use with dedicated accessories SAR is measured with this device at a separation of 0 5 cm to the body while transmitting at the highest certified output power level in all frequency bands of this device Use of other accessories which contain metals may not ...

Страница 6: ...WEEE unitech has set up a policy and process to meet the EU directive 2002 96 EC and update 2003 108 EC concerning electronic waste disposal For more detailed information of the electronic waste disposal of the products you have purchased from unitech directly or via unitech s resellers you shall either contact your local supplier or visit us at https portal unitech eu public WEEE ...

Страница 7: ...2 User s Manual Taiwan NCC Warning Statement 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用者 均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有 干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機需忍受合法通信或工業 科學及醫療用電波輻射性電機設備 之干擾 注意事項 1 使用過度恐傷害視力 2 使用30分鐘請休息10分鐘 2歲以下幼兒不看螢幕 2歲以上每天看螢幕不要超過 1小時 3 減少電磁波影響 請妥適使用 ...

Страница 8: ...cribed service operations The laser safety warning label required by the DHHS IEC for the unitech product s optional laser scanner module is located on the memory compartment cover on the back of the unit Laser information only applies to the products with laser components CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous ...

Страница 9: ... charges are better than a fully uncharged battery Charging a partially charged battery does not cause harm to the unit Keep the battery cool Avoid hot vehicles For prolonged storage keep the battery at a 40 charge level Do not leave the battery uncharged and unused for an extended period of time the battery will wear out and the longevity of the battery will be at least half of one with frequent ...

Страница 10: ...within the stated range of 0 C to 40 C Charging batteries outside of the specified range could damage the batteries and shorten their life cycle CAUTION Do not charge batteries at a temperature lower than 0 C This will and make the batteries unstable and dangerous Please use a battery temperature detecting device for a charger to ensure a safe charging temperature range CAUTION To ensure the unit ...

Страница 11: ...60 C however they may deplete more rapidly at higher temperatures It is recommended to store batteries at room temperature The message above only applies to the usage of the removable batteries For the products with non removable batteries without batteries please refer to the specification of each product Product Operation and Storage Notice The unitech product has applicable operation and storag...

Страница 12: ...pter or same specification of adapter to charge your unitech product Using the wrong power adapter can damage your unitech product The message above only applies to the product connected to the adapter For the products without using the adapters please refer to the specification of each product Hearing Damage Warning Zx 3 Warning The warning shall be placed on the equipment or on the packaging or ...

Страница 13: ... 19 5015 BB Tilburg the Netherlands http eu ute com China Japan Tel 86 59 2310 9966 Tel 81 3 35232766 E mail info cn ute com E mail info jp ute com Address Website Room401C 4F RIHUA International Mansion Xinfeng 3nd Road Huoju Hi tech District Xiamen Fujan China http cn ute com Address Website Kayabacho Nagaoka Building 8F 1 5 19 Shinkawa Chuo Ku Tokyo 104 0033 Japan http jp ute com Asia Pacific M...

Страница 14: ...mited Warranty are free from defects during normal use The warranty period is varied from each country Please consult with your supplier or unitech local office for actual length of warranty period to your purchased product Warranty becomes void if equipment is modified improperly installed or used damaged by accident or neglect or if any parts are improperly installed or replaced by the user ...

Страница 15: ...xii Chapter 1 Overview 1 1 1 Package 1 1 2 Product Detail 2 1 3 Specifications 3 1 4 Getting Started 5 Chapter 2 Command Settings 7 2 1 General setting 7 2 2 USB Interface Setting 9 2 3 Beep Indicator Setting 16 2 4 Trigger Mode 19 2 5 Picklist Mode 21 2 6 Continuous Bar Code Read 22 2 7 Unique Bar Code Reporting 22 2 8 Mirrored Image 23 2 9 Decode Session Timeout 24 2 10 Timeout Between Decodes S...

Страница 16: ...SI 90 3 11 Chinese 2 of 5 95 3 12 Matrix 2 of 5 95 3 13 Inverse 1D 99 3 14 GS1 DataBar 100 3 15 Symbology Specific Security Features 106 3 16 Composite 111 3 17 2D Symbologies 114 3 18 Macro PDF Features 121 3 19 Set Bar Codes Enable Disable 128 3 20 Parameter barcode scanning 128 3 21 Lock Unlock Parameter Scanning 129 3 22 Validate Concatenated Parameter Bar Codes 130 Appendix A ASCII Character ...

Страница 17: ...xv 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual D 2 AIM Code Identifiers 148 ...

Страница 18: ...sure the following contents are in the MS282 gift box If something is missing or damaged please contact your unitech representative The standard package contents MS282 Retail POS 2D Scanner Quick Start Guide Regulatory Compliance Statements NOTE The barcode with an asterisk which appears in the following chapters indicates that it is the default option for the corresponding setting ...

Страница 19: ...018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 1 2 Product Detail Scanner Detail Trigger Key Scan Window LED Indicator ...

Страница 20: ...ing Contrast Scale Minimum 20 Depth of Field DOF PCS 80 SYMBOLOGY X DIM TYPICAL RANGE Near Far 5 mil Code 39 2 0 in 5 1 cm 6 4 in 16 2 cm 5 mil Code 128 2 5 in 6 3 cm 5 0 in 12 7 cm 6 6 mil PDF417 2 5 in 6 3 cm 6 3 in 16 0 cm 10 mil PDF417 1 8 in 4 5 cm 9 0 in 22 8 cm 13 mil 100 UPC 2 0 in 5 0 cm 12 5 in 31 7 cm 20 mil Code 39 2 0 in 5 0 cm 19 5 in 49 5 cm 20 mil Data Matrix 1 5 in 3 8 cm 13 5 in ...

Страница 21: ...sh Marco PDF Buffer Abort Marco PDF Entry Postal Codes US Postnet US Planet Transmit US Postal Check Digit UK Postal Transmit UK Postal Check Digit Japan Postal Australia Post Australia Post Format Electrical Operation Voltage DC 5V 10 Current Consumption Operation mode 235mA Standby mode 60mA Indicator Buzzer LED Environmental ESD Protection Functional after 8K Contact and 12K Air Mechanical Shoc...

Страница 22: ...ectronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 1 4 Getting Started To get started with MS282 please connect USB cable to the USB port of a host PC ...

Страница 23: ... Pull No decode Wake up No Sound No Light Decode Middle Tone Green Blink Snapshot started Low Tone Blinking Snapshot is complete Low Tone No Light Power on Low Tone Middle Tone High Tone No Light Transmission error Four Low Tones No Light Entry error Low Tone High Tone Green Blink Defaults set Parameter entered High Tone Low Tone High Tone Low Tone Green Blink Number entry expected High Tone Low T...

Страница 24: ...tered trademark of unitech Electronics Co Ltd MS282 User s Manual Chapter 2 Command Settings 2 1 General setting 2 1 1 Default Scan below bar code to restore the factory setting Default 2 1 2 Display F W Version Scan below bar code to display F W version Display F W Version ...

Страница 25: ... registered trademark of unitech Electronics Co Ltd MS282 User s Manual 2 1 3 Write to Custom Defaults To create a set of custom defaults select the desired parameter values in this guide and then scan Write to Custom Defaults Restore Defaults Write to Custom Defaults ...

Страница 26: ...2 2 USB Interface Setting 2 2 1 USB Device Type USB HID Keyboard USB CDC Host SNAPI for SCM Setting 2 2 2 USB Static CDC When disabled each device connected consumes another COM port first device COM1 second device COM2 third device COM3 etc When enabled each device connects to the same COM port Enable USB Static CDC Disable USB Static CDC ...

Страница 27: ...can the bar code corresponding to the keyboard type This setting applies only to the USB HID Keyboard Emulation device North American Standard USB Keyboard German Windows French Windows French Canadian Windows 2000 XP French Canadian Windows 95 98 French Belgian Windows Spanish Windows Swedish Windows Portuguese Brazilian Windows Japanese Windows ASCII UK English Windows Italian Windows ...

Страница 28: ... set the delay in milliseconds between emulated keystrokes Select a longer delay for hosts that require slower data transmission No Delay Medium Delay 20 msec Long Delay 40 msec 2 2 5 USB Polling Interval Scan one of the following barcodes to set the polling interval which is the rate at which data transmits between the engine and host computer A lower number indicates a faster data rate 1 msec 2 ...

Страница 29: ...msec 10 msec 2 2 6 USB Caps Lock Override This option applies only to the USB HID Keyboard device Scan Override Caps Lock Key to preserve the case of the data regardless of the state of the Caps Lock key This setting is always enabled for the Japanese Windows ASCII keyboard type and can not be disabled Override Caps Lock Key Enable Do Not Override Caps Lock Key Disable ...

Страница 30: ...k to invert upper and lower case characters on the barcode as if the Caps Lock state is enabled on the keyboard This inversion occurs regardless of the keyboard s Caps Lock state Enable Simulated Caps Lock Disable Simulated Caps Lock 2 2 8 Covert Case Scan below bar code to send don t send non printable characters to the host No Case Conversion Convert All to Upper Case Convert All to Lower Case ...

Страница 31: ...ecognize Scan Send Barcodes With Unknown Characters to send all barcode data except for unknown characters The engine issues no error beeps Scan Do Not Send Barcodes With Unknown Characters to send the barcode characters up to the unknown character The engine issues an error beep Send Barcodes with Unknown Characters Do Not Send Barcodes with Unknown Characters 2 2 10 USB Fast HID Scan Enable USB ...

Страница 32: ...USB HID Keyboard device when Keypad Emulation is enabled Scan Enable Quick Keypad Emulation for a quicker method of emulation using the numeric keypad where ASCII sequences are only sent for ASCII characters not found on the keyboard Enable Quick Keypad Emulation Disable Quick Keypad Emulation 2 2 13 Keypad Emulation with leading Zero Scan Enable Keypad Emulation with Leading Zero to send characte...

Страница 33: ...e of the following bar codes to select whether or not the engine beeps after a good decode If you select Disable Beep After Good Decode the beeper still operates during parameter menu scanning and to indicate error conditions Enable Beep After Good Decode Disable Beep After Good Decode 2 3 2 Beeper volume Scan one of the following bar codes to select a beeper volume Low Volume Medium Volume High V...

Страница 34: ...s Co Ltd MS282 User s Manual 2 3 3 Beeper Tone Scan one of the following bar codes to select a beeper tone for the good decode beep Low Tone Medium Tone High Tone 2 3 4 Beeper Duration Scan one of the following bar codes to select the duration for the good decode beep Short Duration Medium Duration Long Duration ...

Страница 35: ...r codes to select whether or not the LED blinks on a good decode Enable LED on Good Decode Disable LED on Good Decode 2 3 7 Direct Decode Indicator This parameter is only supported in Auto Aim and Standard Level Trigger Mode Scan one of the following bar codes to select optional blinking of the illumination on a successful decode Disable Direct Decode Indicator Illumination does not blink on a suc...

Страница 36: ...ine activates decode processing when it detects a bar code in its field of view After a period of non use the LEDs turn off until the engine senses motion Auto Aim The engine projects the aiming pattern when it senses motion A trigger press activates decode processing After two seconds of inactivity the aiming pattern shuts off Auto Aim with Illumination The engine turns on the aiming pattern and ...

Страница 37: ... 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Trigger Level Presentation Blink Auto Aim Auto Aim with Illumination ...

Страница 38: ...ch allows you to pick and decode a bar code from multiple bar codes printed close together NOTE Enabling Picklist Mode overrides the Disable Decode Aiming Pattern options You can not disable the decode aiming pattern when Picklist Mode is enabled Enable Picklist Mode Always Picklist Mode is always enabled Disable Picklist Mode Always Picklist Mode is always disabled Enable Picklist Mode Always Dis...

Страница 39: ...commend enabling Picklist Mode Disabling Picklist Mode can cause accidental decodes when more than one bar code is in the engine s field of view 2 7 Unique Bar Code Reporting Scan Enable Continuous Bar Code Read Uniqueness to report only unique bar codes while the trigger is pressed This option only applies when Continuous Bar Code Read is enabled Enable Continuous Bar Code Read Disable Continuous...

Страница 40: ... Enable Mirrored Images to scan images in reverse or mirrored as if seen through a mirror This mode is useful in applications requiring scanning through a mirror and using symbologies that do not decode in reverse Enabling this mode when using snapshot video or video viewfinder mode transmits images as mirrored images Disable Mirrored Image Enable Mirrored Image ...

Страница 41: ... 1 second increments from 0 5 to 9 9 seconds The default timeout is 9 9 seconds To set a Decode Session Timeout scan the following bar code and then scan two bar codes from Appendix B Numeric Bar Codes that correspond to the desired on time Enter a leading zero for single digit numbers For example to set a Decode Session Timeout of 0 5 seconds scan this bar code and then scan the 0 and 5 bar codes...

Страница 42: ...when it is left in the engine s field of view The bar code must be out of the field of view for the timeout period before the engine reads the same consecutive symbol It is programmable in 0 1 second increments from 0 0 to 9 9 seconds The default interval is 0 6 seconds To select the timeout between decodes for the same symbol scan the following bar code and then scan two bar codes from Appendix B...

Страница 43: ...bar codes from Appendix B Numeric Bar Codes that correspond to the desired interval in 0 1 second increments 2 11 1 PDF Prioritization Scan Enable PDF Prioritization to delay decoding certain 1D bar codes see Note below by the value specified in PDF Prioritization Timeout During that time the engine attempts to decode a PDF417 symbol e g on a US driver s license and if successful reports this only...

Страница 44: ...view Scan the following bar code and then scan four bar codes from Appendix B Numeric Bar Codes that specify the timeout in milliseconds For example to enter 400 ms scan the following bar code and then scan 0400 The range is 0 to 5000 ms and the default is 200 ms 2 11 3 Mobile Phone Display Mode This mode improves bar code reading performance off mobile phones and electronic displays Scan one of t...

Страница 45: ...ead This transmits the characters NR when a successful decode does not occur before trigger release or the Decode Session Timeout expires Disable No Read This sends nothing to the host if a symbol does not decode NOTE If you enable Transmit No Read and also enable Symbol Code ID Character or AIM Code ID Character for Transmit Code ID Character the engine appends the code ID for Code 39 to the NR m...

Страница 46: ...om Appendix B Numeric Bar Codes that correspond to that value See Appendix A ASCII Character Sets for the four digit codes When using host commands to set the prefix or suffix set the key category parameter to 1 and then set the 3 digit decimal value See Appendix A ASCII Character Sets for the four digit codes The default prefix and suffix value is 7013 CR LF Enter key To correct an error or chang...

Страница 47: ...n Data Transmission Format To change the scan data format scan one of the following bar codes corresponding to the desired format NOTE If using this parameter do not use ADF rules to set the prefix suffix Data As Is PREFIX DATA SUFFIX 1 DATA SUFFIX 1 PREFIX DATA SUFFIX 2 DATA SUFFIX 2 PREFIX DATA SUFFIX 1 SUFFIX 2 DATA SUFFIX 1 SUFFIX 2 PREFIX DATA ...

Страница 48: ...pe of a scanned bar code This is useful when decoding more than one code type In addition to any single character prefix selected the Code ID character is inserted between the prefix and the decoded symbol Select no Code ID character a Symbol Code ID character or an AIM Code ID character For Code ID characters see Symbol Code Identifiers and AIM Code Identifiers Symbol Code ID Character AIM Code I...

Страница 49: ...of unitech Electronics Co Ltd MS282 User s Manual 2 16 Miscellaneous Scanner Parameters Scan the following bar code to add an Enter key carriage return line feed after scanned data Scan the following bar code to add a Tab key after scanned data Add Enter Key Carriage Return Line Feed Tab Key ...

Страница 50: ...e engine attempts to detect motion as best it can with the aim pattern and illumination turned off when the engine is idle Aiming Pattern Low Light Assist Scene Detection Illumination is off but the aim pattern is on when the engine is idle to assist in scene detection Dim Illumination Low Light Assist Scene Detection The aim pattern is off but illumination is on at a dim level to assist in scene ...

Страница 51: ...l cannot perform properly and please scan Set Symbology Defaults clears all custom default values and sets the engine default values 3 2 Enable Disable All Symbologies Scan the Disable All Code Types bar code to disable all symbologies This is useful when enabling only a few code types Scan Enable All Code Types to enable all symbologies This is useful if you need to disable only a few code types ...

Страница 52: ... trademark of unitech Electronics Co Ltd MS282 User s Manual 3 3 UPC EAN JAN 3 3 1 UPC A Scan one of the following bar codes to enable or disable UPC A Enable UPC A Disable UPC A 3 3 2 UPC E Scan one of the following bar codes to enable or disable UPC E Enable UPC E Disable UPC E ...

Страница 53: ...d unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 3 3 3 UPC E1 Scan one of the following bar codes to enable or disable UPC E1 Note UPC E1 is not a UCC Uniform Code Council approved symbology Enable UPC E1 Disable UPC E1 ...

Страница 54: ...h Electronics Co Ltd MS282 User s Manual 3 3 4 EAN 8 JAN 8 Scan one of the following bar codes to enable or disable EAN 8 JAN 8 Enable EAN 8 JAN 8 Disable EAN 8 JAN 8 3 3 5 EAN 13 JAN 13 Scan one of the following bar codes to enable or disable EAN 13 JAN 13 Enable EAN 13 JAN 13 Disable EAN 13 JAN 13 ...

Страница 55: ...ormat If you enabled Bookland EAN select one of the following formats for Bookland data Bookland ISBN 10 The engine reports Bookland data starting with 978 in traditional 10 digit format with the special Bookland check digit for backward compatibility Data starting with 979 is not considered Bookland in this mode Bookland ISBN 13 The engine reports Bookland data starting with either 978 or 979 as ...

Страница 56: ...3 3 8 ISSN EAN Scan one of the following bar codes to enable or disable ISSN EAN Enable ISSN EAN Disable ISSN EAN 3 3 9 Decode UPC EAN JAN Supplementals Decode UPC EAN JAN With Supplementals Only Ignore UPC EAN JAN Supplementals Autodiscriminate UPC EAN JAN with Supplementals Enable 378 379 Supplemental Mode Enable 978 979 Supplemental Mode ...

Страница 57: ...282 User s Manual Enable 977 Supplemental Mode Enable 414 419 434 439 Supplemental Mode Enable Smart Supplemental Mode Supplemental User Programmable Type 1 and 2 Smart Supplemental Plus User Programmable 1 and 2 Smart Supplemental Plus User Programmable 1 Supplemental User Programmable Type 1 Enable 491 Supplemental Mode ...

Страница 58: ... The default is 000 zeroes User Programmable Supplemental 1 User Programmable Supplemental 2 3 3 11 UPC EAN JAN Supplemental Redundancy If you selected Autodiscriminate UPC EAN JAN with Supplementals this option sets the number of times to decode a symbol without supplementals before transmission The range is from 2 to 16 Five or above is recommended when decoding a mix of UPC EAN JAN symbols with...

Страница 59: ...at when reporting UPC EAN JAN bar codes with supplementals Separate Transmit UPC EAN JAN with supplementals with separate AIM IDs but one transmission i e E 0 or 4 data E 1 or 2 supplemental data Combined Transmit UPC EAN JAN with supplementals with one AIM ID and one transmission i e E3 data supplemental data Separate Transmissions Transmit UPC EAN JAN with supplementals with separate AIM IDs and...

Страница 60: ... code data with or without the UPC A check digit It is always verified to guarantee the integrity of the data Transmit UPC A Check Digit Do Not Transmit UPC A Check Digit 3 3 14 Transmit UPC E Check Digit The check digit is the last character of the symbol used to verify the integrity of the data Scan one of the following bar codes to transmit the bar code data with or without the UPC E check digi...

Страница 61: ...Transmit UPC E1 Check Digit The check digit is the last character of the symbol used to verify the integrity of the data Scan one of the following bar codes to transmit the bar code data with or without the UPC E1 check digit It is always verified to guarantee the integrity of the data Transmit UPC E1 Check Digit Do Not Transmit UPC E1 Check Digit ...

Страница 62: ...e part of the UPC symbol and include Country Code and System Character Select the appropriate option for transmitting a UPC A preamble to match the host system Transmit System Character only Transmit System Character and Country Code 0 for USA Transmit no preamble No Preamble DATA System Character SYSTEM CHARACTER DATA System Character Country Code COUNTRY CODE SYSTEM CHARACTER DATA ...

Страница 63: ...e part of the UPC symbol and include Country Code and System Character Select the appropriate option for transmitting a UPC E preamble to match the host system Transmit System Character only Transmit System Character and Country Code 0 for USA Transmit no preamble No Preamble DATA System Character SYSTEM CHARACTER DATA System Character Country Code COUNTRY CODE SYSTEM CHARACTER DATA ...

Страница 64: ...e part of the UPC symbol and include Country Code and System Character Select the appropriate option for transmitting a UPC E1 preamble to match the host system Transmit System Character only Transmit System Character and Country Code 0 for USA Transmit no preamble No Preamble DATA System Character SYSTEM CHARACTER DATA System Character Country Code COUNTRY CODE SYSTEM CHARACTER DATA ...

Страница 65: ...git Disable this to transmit UPC E decoded data as UPC E data without conversion Convert UPC E to UPC A Enable Do Not Convert UPC E to UPC A Disable 3 3 20 Convert UPC E1 to UPC A Scan Convert UPC E1 to UPC A Enable to convert UPC E1 decoded data to UPC A format before transmission After conversion the data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Dig...

Страница 66: ...atible in length to EAN 13 symbols Scan Disable EAN JAN Zero Extend to transmit EAN 8 symbols as is Enable EAN JAN Zero Extend Disable EAN JAN Zero Extend 3 3 22 UCC Coupon Extended Code Scan Enable UCC Coupon Extended Code to decode UPC A bar codes starting with digit 5 EAN 13 bar codes starting with digit 99 and UPC A GS1 128 coupon codes UPC A EAN 13 and GS1 128 must be enabled to use this feat...

Страница 67: ...ne of the following bar codes to select the type of coupon format to support Old Coupon Format Support UPC A GS1 128 and EAN 13 GS1 128 New Coupon Format An interim format to support UPC A GS1 DataBar and EAN 13 GS1 DataBar Autodiscriminate Format Support both Old Coupon Format and New Coupon Format Old Coupon Format New Coupon Format Auto discriminate Coupon Format ...

Страница 68: ...can one of the following bar codes to enable or disable decoding UPC bar codes with reduced quiet zones the margins on either side of the bar code If you select Enable select a 1D Quiet Zone Level Enable UPC Reduced Quiet Zone Disable UPC Reduced Quiet Zone 3 3 25 Code 128 Scan one of the following bar codes to enable or disable Code 128 Enable Code 128 Disable Code 128 ...

Страница 69: ...ecode only Code 128 symbols with 14 characters scan Code 128 One Discrete Length and then scan 1 4 To correct an error or change the selection scan Cancel Two Discrete Lengths Decode only Code 128 symbols containing either of two lengths Select lengths using the bar codes in Appendix B Numeric Bar Codes For example to decode only Code 128 symbols containing either 2 or 14 characters scan Code 128 ...

Страница 70: ... rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 3 3 26 Set Lengths for Code 128 Code 128 One Discrete Length Code 128 Two Discrete Lengths Code 128 Length Within Range Code 128 Any Length ...

Страница 71: ... User s Manual 3 3 27 GS1 128 formerly UCC EAN 128 Scan one of the following bar codes to enable or disable GS1 128 3 3 28 ISBT 128 ISBT 128 is a variant of Code 128 used in the blood bank industry Scan one of the following bar codes to enable or disable ISBT 128 Enable GS1 128 Disable GS1 128 Enable ISBT 128 Disable ISBT 128 ...

Страница 72: ...he engine does not decode single ISBT symbols Disable ISBT Concatenation The engine does not concatenate pairs of ISBT codes it encounters Autodiscriminate ISBT Concatenation The engine decodes and concatenates pairs of ISBT codes immediately If only a single ISBT symbol is present the engine must decode the symbol the number of times set via ISBT Concatenation Redundancy before transmitting its d...

Страница 73: ...Other types of ISBT codes are not concatenated 3 3 31 ISBT Concatenation Redundancy If you set ISBT Concatenation to Autodiscriminate the default use this parameter to set the number of times the engine must decode an ISBT symbol before determining that there is no additional symbol Scan the following bar code and then scan bar codes in Appendix B Numeric Bar Codes to set a value between 2 and 20 ...

Страница 74: ...32 Code 128 FNC4 This feature applies to Code 128 bar codes with an embedded FNC4 character Select Ignore Code 128 FNC4 to strip the FNC4 character from the decode data The remaining characters are sent to the host unchanged When disabled the FNC4 character is processed normally as per Code 128 standard Honor Code 128 FNC4 Ignore Code 128 FNC4 ...

Страница 75: ...0 The engine operates in its most aggressive state while providing sufficient security in decoding most in spec bar codes Code 128 Security Level 1 This option eliminates most misdecodes while maintaining reasonable aggressiveness Code 128 Security Level 2 This option applies greater bar code security requirements if Security Level 1 fails to eliminate misdecodes Code 128 Security Level 3 If you s...

Страница 76: ...ights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 3 3 34 Code 128 Security Level continued Code 128Security Level 0 Code 128 Security Level 1 Code 128 Security Level 2 Code 128 Security Level 3 ...

Страница 77: ...82 User s Manual 3 3 35 Code 128 Reduced Quiet Zone Scan one of the following bar codes to enable or disable decoding Code 128 bar codes with reduced quiet zones the margins on either side of the bar code If you select Enable select a 1D Quiet Zone Level Enable Code 128 Reduced Quiet Zone Disable Code 128 Reduced Quiet Zone ...

Страница 78: ... enable or disable Code 39 3 4 2 Trioptic Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges Trioptic Code 39 symbols always contain six characters Scan one of the following bar codes to enable or disable Trioptic Code 39 NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously Enable Code 39 Disable Code 39 Enable Trioptic Code 39...

Страница 79: ... the following bar codes to enable or disable converting Code 39 to Code 32 NOTE Code 39 must be enabled for this parameter to function 3 4 4 Code 32 Prefix Scan one of the following bar codes to enable or disable adding the prefix character A to all Code 32 bar codes NOTE Convert Code 39 to Code 32 must be enabled for this parameter to function Enable Convert Code 39 to Code 32 Disable Convert Co...

Страница 80: ...39 symbols with 14 characters scan Code 39 One Discrete Length and then scan 1 4 To correct an error or change the selection scan Cancel Two Discrete Lengths Decode only Code 39 symbols containing either of two lengths Select lengths using the bar codes in Appendix B Numeric Bar Codes For example to decode only Code 39 symbols containing either 2 or 14 characters scan Code 39 Two Discrete Lengths ...

Страница 81: ...it to check the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm Only Code 39 symbols which include a modulo 43 check digit are decoded Enable this feature if the Code 39 symbols contain a Modulo 43 check digit Code 39 One Discrete Length Code 39 Two Discrete Lengths Code 39 Length Within Range Default 2 to 55 Code 39 Any Length Enable Code 39 ...

Страница 82: ...git Verification must be enabled for this parameter to function 3 4 9 Code 39 Full ASCII Conversion Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set Scan one of the following bar codes to enable or disable Code 39 Full ASCII NOTE You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously Transmit Code 39 Check Digit Enable Do No...

Страница 83: ...ost aggressive state while providing sufficient security in decoding most in spec bar codes Code 39 Security Level 1 This default setting eliminates most misdecodes Code 39 Security Level 2 This option applies greater bar code security requirements if Security Level 1 fails to eliminate misdecodes Code 39 Level 3 If you selected Security Level 2 and misdecodes still occur select this security leve...

Страница 84: ...educed Quiet Zone Scan one of the following bar codes to enable or disable decoding Code 39 bar codes with reduced quiet zones the margins on either side of the bar code If you select Enable select a 1D Quiet Zone Level Code 39 Security Level 0 Code 39 Security Level 1 Code 39 Security Level 2 Code 39 Security Level 3 Enable Code 39 Reduced Quiet Zone Disable Code 39 Reduced Quiet Zone ...

Страница 85: ...onics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 3 5 Code 93 Scan one of the following bar codes to enable or disable Code 93 Enable Code 93 Disable Code 93 ...

Страница 86: ...ample to decode only Code 93 symbols with 14 characters scan Code 93 One Discrete Length and then scan 1 4 To correct an error or change the selection scan Cancel Two Discrete Lengths Decode only Code 93 symbols containing either of two lengths Select lengths using the bar codes in Appendix B Numeric Bar Codes For example to decode only Code 93 symbols containing either 2 or 14 characters scan Cod...

Страница 87: ...tronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Code 93 One Discrete Length Code 93 Two Discrete Lengths Code 93 Length Within Range Code 93 Any Length ...

Страница 88: ...onics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 3 6 Code 11 Scan one of the following bar codes to enable or disable Code 93 Enable Code 11 Disable Code 11 ...

Страница 89: ...ample to decode only Code 11 symbols with 14 characters scan Code 11 One Discrete Length and then scan 1 4 To correct an error or change the selection scan Cancel Two Discrete Lengths Decode only Code 11 symbols containing either of two lengths Select lengths using the bar codes in Appendix B Numeric Bar Codes For example to decode only Code 11 symbols containing either 2 or 14 characters scan Cod...

Страница 90: ...Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Code 11 One Discrete Length Code 11 Two Discrete Lengths Code 11 Length Within Range Default 4 to 55 Code 11 Any Length ...

Страница 91: ... 11 Check Digit Verification This feature allows the engine to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm Scan one of the following bar codes to specify the number of check digits encoded in the Code 11 symbols or to disable this feature Disable One Check Digit Two Check Digits ...

Страница 92: ...d trademark of unitech Electronics Co Ltd MS282 User s Manual 3 6 3 Transmit Code 11 Check Digits Scan one of the following bar codes to select whether or not to transmit the Code 11 check digit s Do Not Transmit Code 11 Check Digit s Disable Transmit Code 11 Check Digit s Enable ...

Страница 93: ...reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual 3 7 Interleaved 2 of 5 ITF Scan one of the following bar codes to enable or disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 ...

Страница 94: ...mple to decode only I 2 of 5 symbols with 14 characters scan I 2 of 5 One Discrete Length and then scan 1 4 To correct an error or change the selection scan Cancel Two Discrete Lengths Decode only I 2 of 5 symbols containing either of two lengths Select lengths using the bar codes in Appendix B Numeric Bar Codes For example to decode only I 2 of 5 symbols containing either 2 or 14 characters scan ...

Страница 95: ...e for a scan line covering only a portion of the code to transmit as a complete scan yielding less data than is encoded in the bar code To prevent this select specific lengths I 2 of 5 One Discrete Length Two Discrete Lengths for I 2 of 5 applications or increase the I 2 of 5 Security Level I 2 of 5 One Discrete Length Default 14 I 2 of 5 Length Within Range I 2 of 5 Two Discrete Lengths I 2 of 5 ...

Страница 96: ...grity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification USS or the Optical Product Code Council OPCC check digit algorithm 3 7 3 Transmit I 2 of 5 Check Digit Scan one of the following bar codes to transmit I 2 of 5 data with or without the check digit Disable USS Check Digit OPCC Check Digit Transmit I 2 of 5 Check Digit Enable Do Not Tr...

Страница 97: ...Convert I 2 of 5 to EAN 13 Scan Convert I 2 of 5 to EAN 13 Enable to convert 14 character I 2 of 5 codes to EAN 13 and transmit to the host as EAN 13 To accomplish this the I 2 of 5 code must be enabled and the code must have a leading zero and a valid EAN 13 check digit Convert I 2 of 5 to EAN 13 Enable Do Not Convert I 2 of 5 to EAN 13 Disable ...

Страница 98: ...iding sufficient security in decoding most in spec bar codes I 2 of 5 Security Level 1 A bar code must be successfully read twice and satisfy certain safety requirements before being decoded This default setting eliminates most misdecodes I 2 of 5 Security Level 2 This option applies greater bar code security requirements if Security Level 1 fails to eliminate misdecodes I 2 of 5 Security Level 3 ...

Страница 99: ...tronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual I 2 of 5 Security Level 0 I 2 of 5 Security Level 1 I 2 of 5 Security Level 2 I 2 of 5 Security Level 3 ...

Страница 100: ...82 User s Manual 3 7 6 I 2 of 5 Reduced Quiet Zone Scan one of the following bar codes to enable or disable decoding I 2 of 5 bar codes with reduced quiet zones the margins on either side of the bar code If you select Enable select a 1D Quiet Zone Level Enable I 2 of 5 Reduced Quiet Zone Disable I 2 of 5 Reduced Quiet Zone ...

Страница 101: ...r single digit numbers Scan one of the following bar codes to select a length option One Discrete Length Decode only D 2 of 5 symbols containing a selected length Select the length using the bar codes in Appendix B Numeric Bar Codes For example to decode only D 2 of 5 symbols with 14 characters scan D 2 of 5 One Discrete Length and then scan 1 4 To correct an error or change the selection scan Can...

Страница 102: ...n 0 4 1 2 To correct an error or change the selection scan Cancel Any Length Decode D 2 of 5 symbols containing any number of characters within the engine s capability Note Due to the construction of the D 2 of 5 symbology it is possible for a scan line covering only a portion of the code to transmit as a complete scan yielding less data than is encoded in the bar code To prevent this select speci...

Страница 103: ...ding zero for single digit numbers Scan one of the following bar codes to select a length option One Discrete Length Decode only Codabar symbols containing a selected length Select the length using the bar codes in Appendix B Numeric Bar Codes For example to decode only Codabar symbols with 14 characters scan Codabar One Discrete Length and then scan 1 4 To correct an error or change the selection...

Страница 104: ... the bar codes in Appendix B Numeric Bar Codes For example to decode Codabar symbols containing between 4 and 12 characters scan Codabar Length Within Range and then scan 0 4 1 2 To correct an error or change the selection scan Cancel Any Length Decode Codabar symbols containing any number of characters within the engine s capability Codabar One Discrete Length Codabar Two Discrete Lengths Codabar...

Страница 105: ... a space after the first fifth and tenth characters of a 14 character Codabar symbol if the host system requires this data format NOTE Symbol length does not include start and stop characters 3 9 3 NOTIS Editing Scan Enable NOTIS Editing to strip the start and stop characters from a decoded Codabar symbol if the host system requires this data format Enable CLSI Editing Disable CLSI Editing Enable ...

Страница 106: ... registered trademark of unitech Electronics Co Ltd MS282 User s Manual 3 9 4 Codabar Upper or Lower Case Start Stop Characters Scan one of the following bar codes to select whether to transmit upper case or lower case Codabar start stop characters Lower Case Upper Case ...

Страница 107: ... zero for single digit numbers Scan one of the following bar codes to select a length option One Discrete Length Decode only MSI symbols containing a selected length Select the length using the bar codes in Appendix B Numeric Bar Codes For example to decode only MSI symbols with 14 characters scan MSI One Discrete Length and then scan 1 4 To correct an error or change the selection scan Cancel Two...

Страница 108: ...d then scan 0 4 1 2 To correct an error or change the selection scan Cancel Any Length Decode MSI symbols containing any number of characters within the engine s capability Note Due to the construction of the MSI symbology it is possible for a scan line covering only a portion of the code to transmit as a complete scan yielding less data than is encoded in the bar code To prevent this select speci...

Страница 109: ...check digit is optional If the MSI codes include two check digits scan the Two MSI Check Digits bar code to enable verification of the second check digit See MSI Check Digit Algorithm to select second digit algorithms 3 10 3 Transmit MSI Check Digit s Scan one of the following bar codes to transmit MSI data with or without the check digit One MSI Check Digit Two MSI Check Digits Transmit MSI Check...

Страница 110: ...one of the following bar codes to transmit MSI data with or without the check digit 3 10 5 MSI Check Digit Algorithm Two algorithms are available for verifying the second MSI check digit Scan one of the following bar codes to select the algorithm used to encode the check digit Transmit MSI Check Digit s Enable Do Not Transmit MSI Check Digit s Disable MOD 11 MOD 10 MOD 10 MOD 10 ...

Страница 111: ... unitech Electronics Co Ltd MS282 User s Manual 3 10 6 MSI Reduced Quiet Zone Scan one of the following bar codes to enable or disable decoding MSI bar codes with reduced quiet zones If you select Enable select a 1D Quiet Zone Level Disable MSI Reduced Quiet Zone Enable MSI Reduced Quiet Zone ...

Страница 112: ...ctronics Co Ltd MS282 User s Manual 3 11 Chinese 2 of 5 Scan one of the following bar codes to enable or disable Chinese 2 of 5 3 12 Matrix 2 of 5 Scan one of the following bar codes to enable or disable Matrix 2 of 5 Enable Chinese 2 of 5 Disable Chinese 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 ...

Страница 113: ... Matrix 2 of 5 symbols with 14 characters scan Matrix 2 of 5 One Discrete Length and then scan 1 4 To correct an error or change the selection scan Cancel Two Discrete Lengths Decode only Matrix 2 of 5 symbols containing either of two lengths Select lengths using the bar codes in Appendix B Numeric Bar Codes For example to decode only Matrix 2 of 5 symbols containing either 2 or 14 characters scan...

Страница 114: ... last character of the symbol used to verify the integrity of the data Scan one of the following bar codes to determine whether to include the Matrix 2 of 5 check digit with the bar code data Matrix 2 of 5 One Discrete Length Default 14 Matrix 2 of 5 Two Discrete Lengths Matrix 2 of 5 Length Within Range Matrix 2 of 5 Any Length Enable Matrix 2 of 5 Check Digit Disable Matrix 2 of 5 Check Digit ...

Страница 115: ...d trademark of unitech Electronics Co Ltd MS282 User s Manual 3 12 3 Transmit Matrix 2 of 5 Check Digit Scan one of the following bar codes to transmit Matrix 2 of 5 data with or without the check digit Transmit Matrix 2 of 5 Check Digit Do Not Transmit Matrix 2 of 5 Check Digit ...

Страница 116: ...verse decoder setting Regular Only The engine decodes regular 1D bar codes only Inverse Only The engine decodes inverse 1D bar codes only Inverse Autodetect The engine decodes both regular and inverse 1D barcodes Note This parameter does not apply to GS1 DataBar code types The Inverse 1D setting may impact Composite or Inverse Composite decoding See Composite Inverse Regular Inverse Only Inverse A...

Страница 117: ...e variants of GS1 DataBar are DataBar 14 DataBar Expanded and DataBar Limited The limited and expanded versions have stacked variants Scan the appropriate bar codes to enable or disable each variant of GS1 DataBar 3 14 1 GS1 DataBar 14 3 14 2 GS1 DataBar Limited Enable GS1 DataBar 14 Disable GS1 DataBar 14 Enable GS1 DataBar Limited Disable GS1 DataBar Limited ...

Страница 118: ...rip the leading 010 from DataBar 14 and DataBar Limited symbols encoding a single zero as the first digit and report the bar code as EAN 13 For bar codes beginning with between two and five zeros this strips the leading 0100 and reports the bar code as UPC A The UPC A Preamble option that transmits the system character and country code applies to converted bar codes Note that neither the system ch...

Страница 119: ... state while providing sufficient security decoding most in spec bar codes Security Level 1 This setting eliminates most misdecodes while maintaining reasonable aggressiveness Security Level 2 Select this option with greater bar code security requirements if Security Level 1 fails to eliminate misdecodes Security Level 3 If you selected Security Level 2 and misdecodes still occur select this secur...

Страница 120: ...gin required This complies with the original GS1 standard yet can result in erroneous decoding of a DataBar Limited bar code when scanning some UPC symbols that start with digits 9 and 7 Margin Check Level 2 Automatic risk detection This level of margin check can result in erroneous decoding of DataBar Limited bar codes when scanning some UPC symbols If a misdecode is detected the engine operates ...

Страница 121: ...erved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual GS1 DataBar Limited Margin Check Level 1 GS1 DataBar Limited Margin Check Level 2 GS1 DataBar Limited Margin Check Level 3 GS1 DataBar Limited Margin Check Level 4 ...

Страница 122: ...urity decoding most in spec bar codes Security Level 1 This setting eliminates most misdecodes while maintaining reasonable aggressiveness Security Level 2 Select this option with greater bar code security requirements if Security Level 1 fails to eliminate misdecodes Security Level 3 If you selected Security Level 2 and misdecodes still occur select this security level to apply the highest safety...

Страница 123: ... level appropriate for the bar code quality Redundancy Level 1 The engine must read the following code types twice before decoding Codabar 8 characters or less MSI 4 characters or less D 2 of 5 8 characters or less I 2 of 5 8 characters or less Redundancy Level 2 The engine must read all code types twice before decoding Redundancy Level 3 The engine must read code types other than the following tw...

Страница 124: ...18 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Redundancy Level 1 Redundancy Level 2 Redundancy Level 3 Redundancy Level 4 ...

Страница 125: ...cation Security Level 0 The engine operates in its most aggressive state while providing sufficient security decoding most in spec bar codes Security Level 1 This default setting eliminates most misdecodes Security Level 2 Select this option if Security Level 1 fails to eliminate misdecodes Security Level 3 If you selected Security Level 2 and misdecodes still occur select this security level Note...

Страница 126: ...d risk of misdecodes Zebra strongly recommends enabling only the symbologies which require higher quiet zone levels and leaving Reduced Quiet Zone disabled for all other symbologies Options are 1D Quiet Zone Level 0 The engine performs normally in terms of quiet zone 1D Quiet Zone Level 1 The engine performs more aggressively in terms of quiet zone 1D Quiet Zone Level 2 The engine only requires a ...

Страница 127: ...dabar symbologies have an intercharacter gap that is typically quite small Due to various bar code printing technologies this gap can grow larger than the maximum size allowed preventing the engine from decoding the symbol If this problem occurs scan the Large Intercharacter Gaps parameter to tolerate these out of specification bar codes Normal Intercharacter Gaps Large Intercharacter Gaps ...

Страница 128: ...td MS282 User s Manual 3 16 Composite 3 16 1 Composite CC C Scan one of the following bar codes to enable or disable Composite bar codes of type CC C 3 16 2 Composite CC A B Scan one of the following bar codes to enable or disable Composite bar codes of type CC A B Enable CC C Disable CC C Enable CC A B Disable CC A B ...

Страница 129: ...regular decode or inverse decode Regular Only The engine decodes regular Composite bar codes only Before selecting this set Inverse 1D to Regular Only or Inverse Autodetect Inverse Only The engine decodes inverse Composite bar codes only This mode only supports Composite Inverse that includes DataBar combined with CCAB and does not support other 1D 2D combinations Before selecting this first enabl...

Страница 130: ...smission as if they were one symbol UPC Never Linked Transmit UPC bar codes regardless of whether a 2D symbol is detected UPC Always Linked Transmit UPC bar codes and the 2D portion If 2D is not present do not transmit the bar code Autodiscriminate UPC Composites The engine determines if there is a 2D portion then transmits the UPC as well as the 2D portion if present UPC Never Linked UPC Always L...

Страница 131: ...itech Electronics Co Ltd MS282 User s Manual 3 17 2D Symbologies 3 17 1 PDF417 Scan one of the following bar codes to enable or disable PDF417 3 17 2 MicroPDF417 Scan one of the following bar codes to enable or disable MicroPDF417 Enable PDF417 Disable PDF417 Enable MicroPDF417 Disable MicroPDF417 ...

Страница 132: ... one of the following prefixes C1 if the first codeword is 903 905 C2 if the first codeword is 908 or 909 C0 if the first codeword is 910 or 911 Disable Code 128 Emulation to transmit these MicroPDF417 symbols with one of the following prefixes L3 if the first codeword is 903 905 L4 if the first codeword is 908 or 909 L5 if the first codeword is 910 or 911 Scan one of the following bar codes to en...

Страница 133: ... Matrix 3 17 5 Data Matrix Inverse Scan one of the following bar codes to select the Data Matrix inverse decoder setting Regular Only The engine decodes regular Data Matrix bar codes only Inverse Only The engine decodes inverse Data Matrix bar codes only Inverse Autodetect The engine decodes both regular and inverse Data Matrix bar codes Enable Data Matrix Disable Data Matrix Regular Only Inverse ...

Страница 134: ...6 Decode Data Matrix Mirror Images Scan one of the following bar codes to select an option for decoding mirror image Data Matrix bar codes Never Do not decode Data Matrix bar codes that are mirror images Always Decode only Data Matrix bar codes that are mirror images Auto Decode both mirrored and unmirrored Data Matrix bar codes Never Always Auto ...

Страница 135: ...Ltd MS282 User s Manual 3 17 7 Maxicode Scan one of the following bar codes to enable or disable Maxicode 3 17 8 QR Code Scan one of the following bar codes to enable or disable QR Code Note Enabling this also enables QR Inverse QR Mirrored and Linked QR Enable Maxicode Disable Maxicode Enable QR Code Disable QR Code ...

Страница 136: ...Note Enabling this also enables Linked Aztec 3 17 10 Aztec Inverse Scan one of the following bar codes to select the Aztec inverse decoder setting Regular Only The engine decodes regular Aztec bar codes only Inverse Only The engine decodes inverse Aztec bar codes only Inverse Autodetect The engine decodes both regular and inverse Aztec bar codes Enable Aztec Disable Aztec Regular Only Inverse Only...

Страница 137: ...n 3 17 12 Han Xin Inverse Scan one of the following bar codes to select a Han Xin inverse decoder setting Regular Only The engine decodes Han Xin bar codes with normal reflectance only Inverse Only The engine decodes Han Xin bar codes with inverse reflectance only Inverse Autodetect The engine decodes both regular and inverse Han Xin bar codes Enable Han Xin Disable Han Xin Regular Only Inverse On...

Страница 138: ...o not mix bar codes from several Macro PDF sequences even if they encode the same data When scanning a Macro PDF sequence scan the entire sequence without interruption When scanning a mixed sequence two long low beeps low low indicate an inconsistent file ID or inconsistent symbology error 3 18 1 Flush Macro Buffer Scan the following bar code to flush the buffer of all decoded Macro PDF data store...

Страница 139: ...of unitech Electronics Co Ltd MS282 User s Manual 3 18 3 Postal Codes Scan one of the following bar codes to enable or disable US Postnet 3 18 4 US Planet Scan one of the following bar codes to enable or disable US Planet Enable US Postnet Disable US Postnet Enable US Planet Disable US Planet ...

Страница 140: ...eck Digit Scan one of the following bar codes to select whether to transmit US Postal data which includes both US Postnet and US Planet with or without the check digit 3 18 6 UK Postal Scan one of the following bar codes to enable or disable UK Postal Enable US PlanetTransmit US Postal Check Digit Do Not Transmit US Postal Check Digit Enable UK Postal Disable UK Postal ...

Страница 141: ...8 7 Transmit UK Postal Check Digit Scan one of the following bar codes to select whether to transmit UK Postal data with or without the check digit 3 18 8 Japan Postal Scan one of the following bar codes to enable or disable Japan Postal Transmit UK PostalCheck Digit Do Not Transmit UK Postal Check Digit Enable Japan Postal Disable Japan Postal ...

Страница 142: ...r disable Australia Post 3 18 10 Australia Post Format Scan one of the following bar codes to select a format for Australia Post Autodiscriminate or Smart mode Decode the Customer Information Field using the N and C Encoding Tables NOTE This option increases the risk of misdecodes because the encoded data format does not specify the Encoding Table used for encoding Enable Australia Post Disable Au...

Страница 143: ...S282 User s Manual Raw Format Output raw bar patterns as a series of numbers 0 through 3 Alphanumeric Encoding Decode the Customer Information Field using the C Encoding Table Numeric Encoding Decode the Customer Information Field using the N Encoding Table Autodiscriminate Raw Format Alphanumeric Encoding Numeric Encoding ...

Страница 144: ...282 User s Manual 3 18 11 Netherlands KIX Code Scan one of the following bar codes to enable or disable Netherlands KIX Code 3 18 12 UPU FICS Postal Scan one of the following bar codes to enable or disable UPU FICS Postal Enable Netherlands KIX Code Disable Netherlands KIX Code Enable UPU FICS Postal Disable UPU FICS Postal ...

Страница 145: ...et Bar Codes Enable Disable Scan below bar code to enable disable bar code setting Enable Disable 3 20 Parameter barcode scanning Scan one of the following bar codes to select whether to enable or disable the decoding of parameter bar codes including the Set Defaults bar codes Enable Parameter Bar Code Scanning Disable Parameter Bar Code Scanning ...

Страница 146: ... To lock parameter scanning 1 Scan the Lock bar code 2 Scan four bar codes from Appendix B Numeric Bar Codes that represent the desired code Enter leading zeros for numbers below 1000 e g to program a code of 29 enter 0 0 2 9 A lock beep sounds two long high beeps in addition to the parameter entry beep To unlock parameter scanning 1 Scan the Unlock bar code 2 Scan four bar codes from Appendix B N...

Страница 147: ...r bar codes intended for different scanner models or different versions of a scanner This parameter determines how to process concatenated parameter bar codes when the engine encounters an invalid parameter setting in the bar code Disable this to ignore invalid parameters and configure valid parameters Enable this to ignore all parameters if one or more are invalid Disable Validate Concatenated Pa...

Страница 148: ... 131 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Appendix A ASCII Character Sets A 1 ASCII Character Set ...

Страница 149: ... 132 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Страница 150: ... 133 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Страница 151: ... 134 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Страница 152: ... 135 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Страница 153: ... 136 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual A 2 Extended Key Character Set ...

Страница 154: ...d unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Appendix B Numeric Barcodes B 1 Extended Key Character Set For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 5 1 6 2 7 3 8 4 9 ...

Страница 155: ...nitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual B 2 Cancel To correct an error or change a selection scan the bar code below Cancel ...

Страница 156: ...reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Appendix C Alphanumeric BarCodes C 1 Alphanumeric Barcodes For parameters requiring specific numeric values scan the appropriately numbered bar code s Space ...

Страница 157: ... 140 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual _ ...

Страница 158: ... Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual NOTE Do not confuse the following bar codes with those on the numeric keypad 0 5 1 6 2 7 3 8 4 9 End of Message Cancel ...

Страница 159: ... 142 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual A B C D E F G H I J K L M N O P ...

Страница 160: ... 143 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Q R S T U V W X Y Z ...

Страница 161: ... 144 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual a b c d e f g h i j k l m n o p ...

Страница 162: ... 145 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual q r s t u v w x y z ...

Страница 163: ...nitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Appendix D Programming Reference D 1 Symbol Code Identifiers Symbol Code Characters ...

Страница 164: ... 147 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Страница 165: ...nitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual D 2 AIM Code Identifiers Each AIM Code Identifier contains the three character string cm where Flag Character ASCII 93 c Code Character m Modifier Character Aim Code Characters ...

Страница 166: ...itech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual Modifier Characters The modifier character is the sum of the applicable option values ...

Страница 167: ... 150 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Страница 168: ... 151 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Страница 169: ... 152 2018 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd MS282 User s Manual ...

Отзывы: