background image

                  

HT630 Product Reference Guide

 

4.2 How to Create a FormCaching 

 

 

FORMCACHING 
1:YES 
2:NO 
OTHER:EXIT 

You will need to enter Supervisor mode and select “4.FORM” category in order to set the configuration of 
FormCaching (refer to the 

HT630

 

Programming Reference Manual

 for how to enter the Supervisor mode). 

After selecting the “4.FORM” in Supervisor mode, the screen will show as above. The system will first ask 
user to specify four categories of the field specification including 

field prompt, data length, data type

 and

 

device type

 of each data field. After completion to define all data fields, the user should hit [CMD] then 

[ALPHA] keys to end the setup of field specification. This step also determines the number of fields in each 
record and you may continue to set the rest six categories of record specification including 

between field, 

field delimiter, record delimiter, date stamp field, time stamp field and field delay

 

When the FormCaching application is executed, a data file named FORM.DAT will be created to store data. 
The system will not allow the user to redefine FormCaching if the FORM.DAT is existed. It is necessary to 
delete the FORM.DAT in order to change the configuration of FormCaching. 

 
 

4.3 How to Run FormCaching 

 
When FormCaching is enabled, the built-in application can be run by selecting “2.TER” command in User 
mode and then select “2.FORMCACHING”. The FormCaching application will follow the setting as defined 
to display prompting, get input and store data in the file named FORM.DAT. Hit [CMD] then [ALPHA] keys 
to end FormCaching and return to system Ready mode. User may use [

Å

] key to browse a previous data 

record, [

Æ

] key to step to next record, press [C] key to clear the record and then input new value of every 

field of this record. 
After collecting data, the FORM.DAT file can be uploaded to host either by invoking Kermit server in User 
mode described in section 3.2 or remote ESC command described in 3.4. 

 
4.4 Default Setting of FormCaching 

 

In default, the FormCaching is initialized with settings as shown in the table below. 

 
 

DATA FIELD SPECIFICATION: field number=2

 

Category Setting 

Field #1    FIELD PROMPT 

ITEM: 

                 DATA LENGTH 

32 

                 DATA TYPE 

ALPHANUM 

                 DEVICE TYPE 

BOTH 

Field #2    FIELD PROMPT 

QTY: 

                 DATA LENGTH 

                 DATA TYPE 

NUMERIC 

                 DEVICE TYPE 

KEY ONLY 

DATA RECORD SPECIFICATION

 

Category Setting 

BETWEEN FIELD 

Append screen 

FIELD DELIMITER 

RECORD FELIMITER 

CR 

DATE STAMP FIELD 

NONE 

TIME STAMP FIELD 

NONE 

FIELD DELAY 

 

 

Содержание HT630

Страница 1: ...HT630 Product Reference Guide Unitech Version 1 4...

Страница 2: ...ight be low due to storage Recharge the battery when required For procedures on how to charge the battery please refer to 1 5 Quick Start Please note to switch on backup battery and to ensure fully ch...

Страница 3: ...er System 6 2 1 Power System 6 2 2 Power Low Indication 6 2 3 Battery Replacement 6 2 4 Recharging the Battery Pack 7 2 5 Storage and Safety Precautions 8 Chapter 3 Operation 9 3 1 Ready Mode 9 3 2 Us...

Страница 4: ...ese attributes we believe the HT630 is going to satisfy your needs totally Depending on the model you had purchased your terminal might be equipped with 3 different memory RAM configuration range from...

Страница 5: ...static Discharge ESD 4 KV for contact discharge 8 KV for air discharge Back Lit Display Yes Keypads 26 alphanumeric keys one scan trigger phosphorescent material Performance Characteristics CPU X86 Co...

Страница 6: ...to further chapters for detail explanation HT630 Illustrations Figure 0 1 HT630 front view Figure 0 2 HT630 head view Figure 0 3 HT630 tail view Figure 0 4 HT630 side view Figure 0 5 HT630 back view...

Страница 7: ...from the back of the cradle to any power outlet During charging LED above power icon will be displayed red Once it is fully charged LED will be turned to green 2 Or use the standard charging cable wh...

Страница 8: ...fully charged the light will turn to green This LED light shows the power status of the cradle itself When the light is on it is indicated the cradle is powered on Power On After charging completely L...

Страница 9: ...keyboard is initialized to normal mode after being powered on In normal mode the cursor is a block and the keyboard is mainly used to input numeric data and use F1 F4 four function keys COMMAND mode...

Страница 10: ...can be programmed by the high level Windows based JobGen Plus program generation software or programmed by commonly used C compilers including Microsoft C Borland C and Turbo C An executable program...

Страница 11: ...tery used up all data within the terminal will be lost So it is very important to backup all data when replacing backup battery 2 2 Power Low Indication Main Battery When the main power source reaches...

Страница 12: ...star the new unit Make sure to back up your data in terminal before making the replacement the lithium back up battery 2 4 Recharging the Battery Pack When the terminal shows Main battery low message...

Страница 13: ...s may appear to have minimal capacity This type of failure can be remedied by temporarily depleting the battery of its power and recharging it to rejuvenate it This condition can be prevented by avoid...

Страница 14: ...d in User mode to set general system configurations or enter Supervisor mode to set advanced system configurations The Supervisor mode is also protected with password checking to prevent unauthorized...

Страница 15: ...computer In this mode data input from bar code reader or keyboard is displayed on screen and output to RS 232 port Data received from the serial port is displayed on the LCD screen Communication param...

Страница 16: ...le to display power on logo see next section 3 3 Configure the Terminal in SET command There are three categories of general system configuration available in SET command Select the corresponded numbe...

Страница 17: ...ribed in section 3 2 will need the operator to set the terminal to Kermit server mode by selecting user command 3 COM in User mode or calling system function in application program The hardware and so...

Страница 18: ...th and maximum field length 3 DATA TYPE 1 NUMERIC 2 ALPHANUM numeric data 0 9 or alphanumeric data 20H FCH 4 DEVICE TYPE 1 KEY ONLY 2 SCAN ONLY input by keyboard only bar code scanning only or both 3...

Страница 19: ...is necessary to delete the FORM DAT in order to change the configuration of FormCaching 4 3 How to Run FormCaching When FormCaching is enabled the built in application can be run by selecting 2 TER c...

Отзывы: