background image

                  

HT630 Product Reference Guide

 

 

1.8 Triggering Scanner Module 

 

The HT630 can be used with a built-in integrated laser scanner module to input data.  The built-in decoder 
reads most barcode labels.  
 
Users should keep laser window clean to prevent low reading rate of distorted bar code input signal. 

 

1.9 Application Development Environment

 

 

The system of HT630 provides DOS functions and device drivers for application development, including bar 
code decoding, keypad input, display output, serial input/output communication, real-time-clock access and 
power management control. 
 
The HT630 can be programmed by the high-level Windows-based JobGen Plus program generation 
software or programmed by commonly used C compilers including Microsoft C, Borland C and Turbo C. An 
executable program generated by JobGen Plus or created by a compiler is downloaded to the unit and run 
on the unit. 
 

 

JobGen Plus  
 

The JobGen Plus is a Windows-based program generator that gives the user an ease-of-use and 
comprehensive terminal application development environment. Through use-of-JobGen Plus, user can 
design an application program for data collection terminal by simply drawing the data collection 
sequence on paper, and thus, requires minimum programming skills. 
 
For more detailed programming information, please refer to HT630 

Programming Reference Manual,

 

JobGen Pro User's Manual.

 

 

 

 

Содержание HT630

Страница 1: ...HT630 Product Reference Guide Unitech Version 1 4...

Страница 2: ...ight be low due to storage Recharge the battery when required For procedures on how to charge the battery please refer to 1 5 Quick Start Please note to switch on backup battery and to ensure fully ch...

Страница 3: ...er System 6 2 1 Power System 6 2 2 Power Low Indication 6 2 3 Battery Replacement 6 2 4 Recharging the Battery Pack 7 2 5 Storage and Safety Precautions 8 Chapter 3 Operation 9 3 1 Ready Mode 9 3 2 Us...

Страница 4: ...ese attributes we believe the HT630 is going to satisfy your needs totally Depending on the model you had purchased your terminal might be equipped with 3 different memory RAM configuration range from...

Страница 5: ...static Discharge ESD 4 KV for contact discharge 8 KV for air discharge Back Lit Display Yes Keypads 26 alphanumeric keys one scan trigger phosphorescent material Performance Characteristics CPU X86 Co...

Страница 6: ...to further chapters for detail explanation HT630 Illustrations Figure 0 1 HT630 front view Figure 0 2 HT630 head view Figure 0 3 HT630 tail view Figure 0 4 HT630 side view Figure 0 5 HT630 back view...

Страница 7: ...from the back of the cradle to any power outlet During charging LED above power icon will be displayed red Once it is fully charged LED will be turned to green 2 Or use the standard charging cable wh...

Страница 8: ...fully charged the light will turn to green This LED light shows the power status of the cradle itself When the light is on it is indicated the cradle is powered on Power On After charging completely L...

Страница 9: ...keyboard is initialized to normal mode after being powered on In normal mode the cursor is a block and the keyboard is mainly used to input numeric data and use F1 F4 four function keys COMMAND mode...

Страница 10: ...can be programmed by the high level Windows based JobGen Plus program generation software or programmed by commonly used C compilers including Microsoft C Borland C and Turbo C An executable program...

Страница 11: ...tery used up all data within the terminal will be lost So it is very important to backup all data when replacing backup battery 2 2 Power Low Indication Main Battery When the main power source reaches...

Страница 12: ...star the new unit Make sure to back up your data in terminal before making the replacement the lithium back up battery 2 4 Recharging the Battery Pack When the terminal shows Main battery low message...

Страница 13: ...s may appear to have minimal capacity This type of failure can be remedied by temporarily depleting the battery of its power and recharging it to rejuvenate it This condition can be prevented by avoid...

Страница 14: ...d in User mode to set general system configurations or enter Supervisor mode to set advanced system configurations The Supervisor mode is also protected with password checking to prevent unauthorized...

Страница 15: ...computer In this mode data input from bar code reader or keyboard is displayed on screen and output to RS 232 port Data received from the serial port is displayed on the LCD screen Communication param...

Страница 16: ...le to display power on logo see next section 3 3 Configure the Terminal in SET command There are three categories of general system configuration available in SET command Select the corresponded numbe...

Страница 17: ...ribed in section 3 2 will need the operator to set the terminal to Kermit server mode by selecting user command 3 COM in User mode or calling system function in application program The hardware and so...

Страница 18: ...th and maximum field length 3 DATA TYPE 1 NUMERIC 2 ALPHANUM numeric data 0 9 or alphanumeric data 20H FCH 4 DEVICE TYPE 1 KEY ONLY 2 SCAN ONLY input by keyboard only bar code scanning only or both 3...

Страница 19: ...is necessary to delete the FORM DAT in order to change the configuration of FormCaching 4 3 How to Run FormCaching When FormCaching is enabled the built in application can be run by selecting 2 TER c...