Remark: Usually the shiny side is the polyester side, it contact the roller.
The dull side is coated with adhesive. For the matte film, the two sides have
minor difference, please especially be careful. Heat the film with lighter can
easily tell the polyester side and adhesive side. The adhesive side must face
away against to the roller.
Caution: For hot laminating, the top and bottom roll film must have same
width, besides, the top film and bottom film must be aligned. (If the film is
not in alignment, loose the bolt on core adapter and align it.)
Remark: the machine will not power on without the feed table and the
safety shield in the proper positions.
Slide the roll film onto the roll shaft (follow the above instruction, do not load
the film in wrong side). Hold the roll film on the core adapter, the core adapter
can hold the core of the roll film, to prevent it rotating. Screwing the bolt on the
core adapter. Put the rolls on the brackets. Make sure it is fully seated.
Step 7: Make sure there is still enough slack in the web. Close the rollers with
the knob on the right side of the laminator. With the film draped over the two
heating rollers, and melted or taped together, push one edge of the threading
card between the heating rollers so that the film is firmly positioned. Make sure
the rollers are in closed position. If a threading card is not available, any piece
of card stock or poster board will work.
Step 4: With both roll films threaded and installed in their respective brackets,
unwind the top and bottom supply rolls about half-turn each. This will provide
enough slack in the web to allow the feed table to slide on easily.
Step 5: Slide the feed table into position and lock the active bolt.
Step 6: Position the safety shield forward toward the roller and lock the active
bolt.
8
5
OPERATION INSTRUCTIONS
FUNCTIONS OF DIGITAL DISPLAY,
CONTROL PANEL AND EMERGENCY STOP
Tension knob
Spring
Bracket
Friction plate
Bushing
Core adapter
Roll film
Bolt
Bracket
Bushing
Core adapter
Bolt
Tension knob
Friction plate
1. Digital display and Functions
When the sensor is in open circuit, shows "OPN"
When the sensor is in short circuit, shows "CLS"
2. Button function of control panel
1) Temperature control
1) Protecting function of temp sensor's open circuit and shot circuit
2) Automatic memory function
After pressing the control button, within 3 seconds, the machine can
automatically save the setting data (speed, temperature, running mode),
these data can be recovered for next operation.
Note: Do not switch off the machine within 3 seconds after pressing
the control button, in case the CPU might damaged.
A)These can be used for increasing or decreasing Temp.
manually. The temp can be increased or decreased
by 1
when these buttons are pressed. Pressing the
button, the temp will be increased or decreased
continuously until you loose the button.
B)The range of temp that can be adjusted manually is
0
-140
.
C)When the temp reach 140
, the over-heat protecting
system will run automatically.
D)When pressing the temp control button, it indicates
the setting temp. When losing the button for 3
seconds, it indicates the present
automatically.
E)When the setting temp is reached, the READY lamp
is light.
℃
℃
℃
℃
temp.
UP
DOWN
Temp control button