background image

 

exhaustible parts such as the conductive rubber pad and drill bit in order to secure 
longer use of the machine. 

 

Trouble Shooting: 

1.

 

Failure to Work Properly 

 

Check power connection in case of no-power. 

 Renew the fuse when damaged. 

 Renew the switch when damaged. 

 Renew the circuit plate when buttons on the operating panel fail to work properly. 

 Renew the operating circuit plate when damaged. 

 Close the protecting case properly when otherwise done. 

2.

 

Successive Blowout 

 Replace the fuse with a new one of specified capacity in case of capacity problem. 

 Check the circuit to ensure no short circuit. 

3.

 

Slower Descending of Drill Bit

 

 

Renew the damaged motor, if any. 

 Renew the damaged operating panel, if any. 

4.

 

Slower Performance of Drill Bit

 

 Renew the damaged motor of the drill bit, if any. 

 Fasten the motor screw in case of loose wire connection. 

 Renew the damaged condenser of the motor, if any. 

5.

 

Nor-return of Drill Bit 

 Renew the damaged operating panel. 

 Make sure the conductive rubber pad touches well. 

 

Attention: 

1.

 

The power voltage should remain 210v

230v. 

2.

 

The machine is designed for paper drilling other than plastics or metal wares. 

3.

 

The  conductive  rubber  pad  should  be  revolved  when  used  for  over  100  times  at 
the one same position. 