292427-BIM-A-0307
Unitary Products Group
23
ACCESSORIES
•
ELECTRIC HEATER - Add 13” to unit height when used.
•
SUPPLY AIR PLENUM - Add 24-1/4” to unit height when used.
•
BASE - Add 20” to unit height when used.
FIGURE 16 - UNIT DIMENSIONS KBU060
+./#+/54
2EMOVEDONLYWHEN
%LECTRIC(EAT!CCESSORY
ISUSED
(/,%7"53().'
).2%!20!.%,
&OR,OW6OLTAGE
#ONTROL0ANEL
+./#+/54
).2%!20!.%,
&OR0OWER7IRING
!)2
/54
",/7%2-/4/2
!.$$2)6%
!##%330!.%,
4HISSIDEINLY
&),4%2!##%33
0!.%,4HIS
SIDEONLY
(/,%7)4('2/-
-%4&/2
,)15)$,).%
(/,%7)4(
GROMMET
&/2
35#4)/.,).%
/$$2!).
#/..-USTBE
TRAPPED
!)2
).
TABLE 16: UNIT CLEARANCES KBU060
MINIMUM CLEARANCES
060
Side with RETURN AIR opening
24”
Side with SUPPLY AIR opening
1
24”
Side with PIPING CONNECTIONS
2
36”
Side opposite with PIPING CONNECTIONS
12”
Side with access for both POWER & CONTROL
WIRING
3,
-
Bottom
4
-
1.
Overall dimensions of the unit will vary if an electric
heater, a supply air plenum or a base is used.
2.
This dimension is required for removal of the coil. Only
26” is required for normal service.
3.
Although no clearance is required for service and oper-
ation, some clearance may be required for routing the
power and control wiring.
4.
Allow enough clearance to trap the condensate drain
line.
All dimensions are in inches. They
are subject to change without notice.
Certified dimensions will be provided
upon request.