background image

035-14519-002 Rev. B (1204)

VARIABLE SPEED SINGLE PIECE 
MODULAR AIR HANDLERS

MODELS: F2FV060 / F3FV060(T)

INSTALLATION MANUAL

ISO 9001

Certified Quality

Management System

SAFETY

This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.

Understand and pay particular attention to the signal words 

DANGER

,

WARNING

, or 

CAUTION

DANGER 

indicates an 

imminently

 hazardous situation, which, if not

avoided, 

will result in death or serious injury

.

WARNING 

indicates a 

potentially

 hazardous situation, which, if not

avoided, 

could result in death or serious injury

.

CAUTION 

indicates a potentially hazardous situation, which, if not

avoided 

may result in minor or moderate injury.

 It is also used to

alert against unsafe practices and hazards involving only property dam-
age.

Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.

This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.

TABLE OF CONTENTS

SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SPECIFIC SAFETY RULES AND PRECAUTIONS  . . . . . . . . . . . . . . . 2
SAFETY REQUIREMENTS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GENERAL INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSPECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HORIZONTAL DRAIN PAN CONVERSION   . . . . . . . . . . . . . . . . . . . . 3
DUCT CONNECTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FILTERS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SUSPENSION KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
REFRIGERANT LINE CONNECTION  . . . . . . . . . . . . . . . . . . . . . . . . .6
ELECTRIC HEATERS & OPERATING CONTROLS  . . . . . . . . . . . . . .6
LOW VOLTAGE CONTROL CONNECTION  . . . . . . . . . . . . . . . . . . . .7
LINE POWER CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
BLOWER SPEED SELECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
DRAIN CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
COIL CLEANING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
LUBRICATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
CONDENSATE DRAINS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

LIST OF FIGURES

Plenum Clearances  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Typical Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Filter Access & Drain Pan Conversion / Coil Baffle  . . . . . . . . . . . . . . . 4
Dimensions & Duct Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Typical Horizontal Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
TXV Bulb Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Bulb Location  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Orifice Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Control Board  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Electric Heaters in Horizontal Configuration - Right Hand Air Flow  . . .7
Line Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
CFM Selection Board Detail  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Control Box  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Cooling Models with Electric Heat Wiring  . . . . . . . . . . . . . . . . . . . . . .10
Two-Stage Cooling Wiring   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Heat Pump Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

LIST OF TABLES

Dimensions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installed Orifice or TXV Sizes   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CFM / Tap Selection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Physical and Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Conversion Table  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Data - 1 Ø - 208/230-1-60   . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Data - 3 Ø - 208/230-3-60   . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Electrical Data - Cooling Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Electrical Data - (for Single Source Power Supply) - 
Copper Wire 208/230-1-60  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Electrical Data - (for Single Source Power Supply) - 
Copper Wire 208/230-3-60  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Electrical Data - (for Multi-Source Power Supply) - 
Copper Wire 208/230-1-60  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Содержание F2FV060

Страница 1: ...s including but not limited to building electrical and mechanical codes TABLE OF CONTENTS SAFETY 1 SPECIFIC SAFETY RULES AND PRECAUTIONS 2 SAFETY REQUIREMENTS 2 GENERAL INFORMATION 2 INSPECTION 2 LIMI...

Страница 2: ...INFORMATION This Single Piece Air Handler provides the flexibility for installation in any upflow or horizontal application These versatile models may be used for cooling or heat pump operation with...

Страница 3: ...n to remove pan from position 4A if factory installed 3 Position horizontal pan as required in either A or B position locking it into the vertical drain pan as shown 4 Horizontal drain pans have 4 plu...

Страница 4: ...THE SIDES AND REAR OF UNIT SUPPORT BRACKET 060 COIL BAFFLE SHOWN IN RIGHT HORIZONTAL POSITION FIGURE 4 Dimensions Duct Sizes SHIPPING BRACKET REMOVE PRIOR TO INSTALLATION 2 SCREWS 10 3 8 J DRAIN CONNE...

Страница 5: ...size filter Standard 1 size permanent or throw away filter may be used or permanent washable filters are available using model num ber 1PF603BK only See Table 4 for filter size SUSPENSION KITS A suspe...

Страница 6: ...fitting hand tight and turn an additional 1 8 turn to seal NOTE This procedure should be done within 2 minutes to keep air and contaminates from entering the coil If the orifice cannot be replaced an...

Страница 7: ...y with local and national electrical code requirements Read and heed all unit caution labels NOTE It is possible to vary the amount of electric heat turned on during the defrost cycle of a heat pump S...

Страница 8: ...d Remove for Heat Pump for heat pump operation See Figure 12 To Set Electric Heat CFM The blower speed required for the Electric Heat is different than cooling Refer to the label in the bag attached t...

Страница 9: ...240V F2FV060H06 F3FV060H06T 2HK 6500806B 0 5 1335 5 6 7 5 19 1 25 6 3 8 5 0 5 6 7 5 5 6 7 5 2HK 6501006B 7 5 10 0 25 6 34 1 3 8 5 0 7 5 10 0 7 5 10 0 2HK16501506B 11 3 15 0 38 6 51 2 3 8 5 0 7 5 10 0...

Страница 10: ...60 8 6 2HK06501525B 48 6 52 9 50 60 8 6 1 May be 0 or 1 No Breaker or Breaker 2 O C P Over Current Protection device must be HACR type Circuit Breaker or Time Delay fuse TABLE 11 Electrical Data for...

Страница 11: ...HEAT 3 4 THERMOSTAT OUTDOOR UNIT DEFROST CONTROL GND SCREW TERMINAL NOT AVAILABLE ON ALL THERMOSTATS IMPORTANT NOTE HEAT PUMP JUMPER ON THE CFM SELECTION BOARD MUST BE REMOVED WHEN AIR HANDLER IS USED...

Страница 12: ...nd the local atmospheric conditions Clean filters keep unit efficiency high COIL CLEANING If the coil needs to be cleaned or replaced it should be washed with Calgon coilclean mix one part Coilclean t...

Отзывы: