background image

22

Unitary Products Group

DGAM, DGAT, & DLAS SERIES

HSI GAS DOWN FLOW FURNACE

CODE

USED ON

MODEL

PART

NUMBER

DESCRIPTION

1

All

024--27666--000

Pressure Switch

2

All

028--11957--000

Silicone Tube

3

All

7990--3591

Limit Switch (Upper)

4

All

7990--6501

Booster Assembly (Includes Motor)

5

All

7990--314P

Booster Motor -- 3000 RPM

6

All

7990--401

Cover (Control Box)

7

All

031--01910--000

IIntegrated Control

8

All

7990--328P

Gas Valve (24V .3 Amp)

9

----

--------------

--------------------------

10

All

7945--5151/C

Valve Bracket

11

----------------

----------------------

------------------------

12

----

--------------

--------------------------------

13

All

7990--368P

Thermostat

14

All

7945--3011

Gasket Pkg. (Heat Exchanger)

15

All

7995--5751

Heat Exchanger (with Gaskets)

16

All

7975--3881

Remote Sensor

17

All

7970--3331

System Switch

18

All

7990--402

Field Wiring Cover

19

All

2940A3541

Transformer (115--24V 40VA)

20

056

070,075

090

7945--3281/A

7970--3281/A

7995--3281/A

Limit Switch (OPEN--140

º

CLOSE--110

º

Limit Switch (OPEN--145

º

CLOSE--115

º

)

Limit Switch (OPEN--150

_

CLOSE--120

_

)

21

All

7970--5851/A

Burner Assembly (Less Gas Valve)

22

All

1474--0521

Hot Surface Ignitor

23

All

7970--179

Ignitor Shield

24

All

7945--1631/A

Mounting Plate (Burner)

25

----

------------

--------------------------

26

All

1214--2511

Filter (16 x 20 x 1 Disposable) (2 Required)

27

DGAM

DLAS, DGAT

7975--1561/B

7990--1561/A

Panel (Upper)

Panel (Upper)

28

DGAM,DGAT

DLAS

7956--1571/A

7956--1631/A

Panel (Lower)

Panel (Lower)

BLOWER PARTS

29

DGAM

1468--220P

Motor

DGAT, DLAS

(057, 070, 075)

7966--311P

Motor

090

1468--212P

Motor

30

All

7966A530

Scroll

31

All

2702--4091

Motor Mount(3/Pkg.)

32

All

7680--348

Connector Plug

33

All

7670--6391

Motor Clamp

34

090

DGAM

1499--4461

1499--4471

Run Capacitor

Run Capacitor

35

All

1472--2751

Blower Wheel

(10 5/8 Dia. x 7 1/8 x 1/2)

BURNER ORIFICE CHART

MODEL

056

070

075

090

Nat.

9951--1361

9951--1541

9951--1611

9951--1801

LP

9951--0821

9951--0931

9951--0981

9951--1061

NOTE:

All parts with three digit suffix numbers are “Special Order” Parts. These parts are subject to factory availability and require
extra time for delivery.

Содержание DLAS

Страница 1: ...ation adjustment service or maintenance can cause injury or property dam age Please refer to all the instructions of this manual for proper installation procedures Im proper installation will void the...

Страница 2: ...nace Doors 19 Finish and Trim 19 Furnace and Air Conditioner Installations 19 HIGH ALTITUDE DERATION CHART 20 Natural Gas 20 Propane Gas 20 REPAIR PARTS 21 22 LIST OF FIGURES FIGURE 1 Furnace Dimensio...

Страница 3: ...0BDF NATURAL GAS 70 000 57 000 DGAT075BDF NATURAL GAS 75 000 61 000 DGAT090BDF NATURAL GAS 90 000 72 000 DLAS Automatic Ignition Heating Only No Coil Cabinet Model No Factory Equipped for use with Inp...

Страница 4: ...nt CSA stan dard CAN CGA Z240 4 2 Installation Require ments for Propane Appliances and Equipment in Recreational Vehicles 2 Unit electrical wiring and grounding shall complywith current CSA standard...

Страница 5: ...cation of 200 or less 6 Non combustible pans having one inch upturned flanges are located beneath openings in the floor re turn duct system 7 Wiring materials located in the return duct system conform...

Страница 6: ...er grill an undercut of 2 1 2 will provide 50 Sq In of free area 1 The closet door MUST have a minimum of 250 Square In ches of free area in the upper half of the door and a mini mum of 50 Square Inch...

Страница 7: ...installed on a new home do the following 1 Inspect the furnace top collars for signs of insulation or ceiling debris which might have fallen in during cutting of the ceiling and roof holes Remove all...

Страница 8: ...ITCH SLANT FLASHING 3 12 PITCH DLAS COAS Furnaces DGAT DGAM COAT CGAT Furnace Installation Dimensions Installation Dimensions A Adjustable Height B Adjustable Height 4000 7101 C 4000 7121 C 4000 7141...

Страница 9: ...DGAT DGAM COAT CGAT Furnace Installation Dimensions Installation Dimensions A Adjustable Height B Adjustable Height 4000 8101 C 4000 8181 C 4000 9161 A 4000 9181 A 85 to 101 99 to 129 101 to 117 115 t...

Страница 10: ...he furnace may be installed on combustible flooring without a separate sub base DUCT CONNECTOR DIMENSIONS DUCT CONNECTOR DIMENSIONS DUCT CONNECTORS FOR SCREW ATTACHMENT DUCT CONNECTORS FOR TAB ATTACHM...

Страница 11: ...0 715 and U L standard 181 INSTALLATION OF TAB ATTACHMENT DUCT CONNECTORS 1 Make floor cut out as shown in figure 8 2 Determine the depth of the floor cavity from the sur face of the floor to the top...

Страница 12: ...w hole is provided in the pipe and collar Excessively long screws may extend to flue pipe and puncture it Screws are not to exceed 1 1 2 in length NOTE Combustion air tube and flue pipe are part of th...

Страница 13: ...n the left side of the furnace See Figure 14 If conduit is used it should be secured to the control box 3 Connect the hot wire to the BLACK pigtail lead and the neutral wire to the WHITE pigtail lead...

Страница 14: ...bove the floor The preferred location is on an inside wall situated in an area with good air circulation and where the temperature will be reasonably representative of other living areas the thermosta...

Страница 15: ...itch To Earth Ground Neutral L1 115 VAC To A C Condensing Unit If equipped Incoming Power Must Be Polarized Observe Color Coding NEUTRALS Ground Screw HEAT COOL L1 XFMR COM 24 VAC RED BLK BRN WHT WHT...

Страница 16: ...Earth Ground Neutral L1 115 VAC To A C Condensing Unit If equipped Incoming Power Must Be Polarized Observe Color Coding NEUTRALS Ground Screw HEAT COOL L1 XFMR COM 24 VAC RED BLK WHT WHT BLK BLU RED...

Страница 17: ...r is then reduced to 10 W C IMPORTANT When converting valve from or to Pro pane gas it will be necessary to change main burner ori fice to prevent an underfired or overfired condition See label inside...

Страница 18: ...PRONOUNCED YELLOW WITH ORANGE TIPS LIGHT BLUE NO BLUE TIPS EXTENDING FROM THE END OF THE BURNER DARK BLUE DARK BLUE LONG AND EXTREMELY PRONOUNCED BLUE TIPS EXTENDING FROM THE END OF THE BURNER WHTISH...

Страница 19: ...e and air condi tioner form operating at the same time This interlock system usually contains a heat cool switch which must be turned to either HEAT or COOL to activate either heating or cooling opera...

Страница 20: ...0 128 30 9951 1281 0 136 29 9951 1361 0 152 24 9951 1521 PROPANE GAS 56 000 Input 70 000 Input 75 000 Input 90 000 Input Elevation Orifice Dia Drill Size Part Orifice Dia Drill Size Part Orifice Dia D...

Страница 21: ...flow Furnace Repair Parts List for DGAM056BDF DLAS056BDF DGAM075BDF DLAS075BDF Repair Parts List for DGAT056BDF DGAT070BDF DGAT075BDF DGAT090BDF 13 26 27 28 15 14 14 30 34 35 33 32 31 29 22 21 16 23 2...

Страница 22: ...EN 145 CLOSE 115 Limit Switch OPEN 150_ CLOSE 120_ 21 All 7970 5851 A Burner Assembly Less Gas Valve 22 All 1474 0521 Hot Surface Ignitor 23 All 7970 179 Ignitor Shield 24 All 7945 1631 A Mounting Pla...

Страница 23: ...23 Unitary Products Group...

Страница 24: ...ary Products Group Subject to change without notice Printed in U S A Copyright E by Unitary Products Group 1999 All rights reserved 1973 106 F Rev 2 599 5005 York Drive Unitary Products Group Norman O...

Отзывы: