Installation Sheet 406.2
Series 4000
UniRac, Inc.
www.unirac.com
3201 University Boulevard SE, Suite 110
Albuquerque NM 87106-5635 USA
505.242.6411
505.242.6412 Fax
Page
2
10 year limited Product Warranty
UniRac, Inc., warrants to the original purchaser
(“Purchaser”) of product(s) that it manufactures
(“Product”) at the original installation site that
the Product shall be free from defects in material
and workmanship for a period of ten (10) years,
from the earlier of 1) the date the installation
of the Product is completed, or 2) 30 days after
the purchase of the Product by the original
Purchaser. This Warranty does not cover damage
to the Product that occurs during its shipment,
storage, or installation.
This Warranty shall be VOID if installation of
the Product is not performed in accordance
with UniRac’s written installation instructions,
or if the Product has been modifi ed, repaired, or
reworked in a manner not previously authorized
by UniRac IN WRITING, or if the Product is
installed in an environment for which it was
not designed. UniRac shall not be liable for
consequential, contingent or incidental damages
arising out of the use of the Product by the
Purchaser under any circumstances.
If within the specifi ed Warranty period the
Product shall be reasonably proven to be
defective, then UniRac shall repair or replace
the defective Product, or any part thereof,
in UniRac’s sole discretion. Such repair or
replacement shall completely satisfy and
discharge all of UniRac’s liability with respect to
this limited Warranty. Under no circumstances
shall UniRac be liable for special, indirect or
consequential damages arising out of or related
to use by Purchaser of the Product.
Manufacturers of related items, such as PV
modules and fl ashings, may provide written
warranties of their own. UniRac’s limited
Warranty covers only its Product, and not any
related items.
Final adjustments
Once the rack/PV module assembly is at-
tached to the pole, raise and rotate the
rack/PV module assembly as needed.
Never let the assembly slide down
the pole.
Torque the fl ange nuts on the
U-bolt to 30 foot-pounds and the channel
bracket bolts to 20 foot-pounds. Then
tilt the rails to bring the module to the
desired angle. Torque the bracket/rail
bolts to 18–20 foot-pounds.
Torque module bolts to 15 foot-pounds.
Assembly
The exploded view illustrates the rela-
tionship of the parts. Assembly order is
not critical. You may work either from
the pole outward, or assemble the rack,
PV module, and electrical components
before mounting the rack/PV module
assembly on the pole.
Loosely assemble all components.
The U-bolt and
3
/
8
-
inch fl ange nuts at-
tach the channel to the pole. Be certain
that the channel is centered on the pole,
then securely tighten the fl ange nuts.
Channel
Bracket
Pivot hole
Arc hole
Rail
Mounting pole
The
5
/
16
-
inch hardware attaches the
brackets to the channel and the rails to
the brackets. Ensure that:
• brackets sit with the pivot hole
above the arc hole;
• rail slots face upward.
The
¼ -
inch hardware attaches the PV
module to the rack. Ensure that you:
• center the module on the channel;
• place the module as close as pos-
sible to the pole end of the rails.