background image

Installation Guide / 

Guía de instalación

 

for Oberon Model 1040

-

CCOAP3800

 

para Modelo Oberon 

1040

-

CCOAP3800

 

 

 

 

Mounting Solutions for WiFi Access Points

 

"Oberon" and all other marks where denoted are trademarks of Oberon Inc.  

©

1999

-

2018 Oberon Incorporated. All rights reserved.

 

"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. © 1999

-

2017 Oberon Incorporated. Todos los derechos reserve.

 

EPN 3086 

-

 Rev. #1 02/07/2018

 

Cloud/canopy/suspended ceiling mounting kit for most vendors’ APs and 
antennas. A cutout is made in the ceiling panel, the panel bridge is 
placed above the ceiling panel, and the trim is then drawn into the panel 
bridge with a torsion spring, as in certain recessed lighting fixtures, with 
only the front face exposed for optimal wireless coverage. 

 

Kit de montaje para cielorraso suspendido/dosel/nube para la mayoría 
de las antenas y AP de los proveedores. Se realiza un recorte en el 
panel del cielorraso, se coloca el puente del panel por encima del panel 
del cielorraso, se lleva al puente del panel con un muelle de torsión, 
como en ciertos accesorios de iluminación empotrados, con solo la cara 
frontal expuesta para tener una cobertura inalámbrica óptima. 

 

Instructions are for typical install conditions. 

 

Instructions may not be correct for all installations due to building 
design, construction materials or methods used and/or building or 
site conditions. Consult a contractor or architect for recommenda-
tions. For product questions call (+1) 877

-

867

-

2312.

 

 

Las instrucciones son para condiciones típicas de instalación. 

 

Las instrucciones pueden no ser correctas para todas las instala-
ciones según el diseño del edificio, materiales de construcción o 
métodos utilizados, o condiciones del edificio o del lugar. Consulte 
a un contratista o arquitecto para obtener recomendaciones. Si 
tiene preguntas con respecto al producto, llame al (+1) 877

-

867

-

2312.

 

Thank you for choosing Oberon./ Gracias por elegir Oberon.

 

WARNING 

/ ADVERTENCIA

 

Follow manufacturer's instructions for hand or power tools. 
Always use safety glasses. Failure to do so may result in injury 
and/or product damage.

 

Siga las instrucciones del fabricante para herramientas manu-
ales o eléctricas. Utilice siempre gafas de seguridad. Si no lo 
hace, podría producirse lesiones y / o daños al producto.

 

WARNING 

/ ADVERTENCIA

 

Use caution when working at elevated heights. Follow manu-
facturer's instructions for ladders and/or scaffolding. Failure to 
do so may result in injury or death.

 

Tenga cuidado al trabajar a alturas elevadas y alrededor de las 
aberturas de la unidad. Siga las instrucciones del fabricante 
para laddors y / o andamios. Si no lo hace, podría causar le-
siones o la muerte.

 

Important Information for Model 1040 

/ Información importante sobre la instalación del modelo 1040

 

Read guide from beginning to end before beginning installation. 
Read all warnings and cautions before beginning unit installa-
tion. Check with your local building code official to identify and 
confirm compliance with local building code requirements. This 
installation guide covers installing your Model 1040 in a typical 
environment. The appropriate method for your installation may 
vary based on building design, application, and industry practic-
es.

 

Lea la guía de principio a fin antes de comenzar la instalación. 
Lea todas las advertencias y precauciones antes de comenzar la 
instalación de la unidad. Verifique con un oficial de código 
edilicio de su localidad para identificar y confirmar el cumpli-
miento con los requisitos locales del código de edificación. Esta 
guía de instalación cubre la instalación del Modelo 3032 en un 
entorno adecuado. El método apropiado para la instalación 
puede variar según el diseño del edificio, la aplicación y las 
prácticas de la industria.

 

1. Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical Continuity of Metal Raceways and 
Enclosures) and 300.11 (Securing and Supporting). Independent support wires or other means must be used for the installation of this product in the ceiling. 
Acoustical, suspended, false, drop and concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mounted 
products have four support wire tabs on the back box. These tabs shall be used for supporting the product with independent support wires, wire rope, thread-
ed rod, or other secure support means of adequate gauge and fire resistance.

 

2. When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door from accidentally swinging open.

 

3. When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open. 

 

4. This enclosure has a maximum operating ambient of 55º C (131º F). The temperature within the enclosure may not exceed this temperature, depending on 
power dissipation within enclosure.

 

5. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be maintained for the safeoperation of the equip-
ment.

 

6. This product is intended to be installed by trained personnel.

 

7. Only Listed ITE products shall be installed within the enclosure.

 

8. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or replacement.

 

9. Maximum weight to be installed in the unit is 25 lbs.

 

10. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non

-

metal material that complies with UL 2043 or UL 1479.

 

11. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.

 

12. AC Power is not to be used inside the enclosure.

 

13. A readily accessible disconnect device shall be incorporated in the building installation wiring.

 

14. See OSHPD approved installation drawing where applicable.

 

1. Los productos a montar en el cielorraso deben instalarse de acuerdo con los párrafos 300.10 (Continuidad Eléctrica de Canalizaciones y Recintos de Met-
al) y 300.11 (Aseguramiento y Soportes) del Código Eléctrico Nacional. Deben utilizarse cables independientes de soporte u otros medios para la instalación 
de este producto en el cielorraso. Las rejillas de cielorraso estriadas acústicas, suspendidas, falsas, en desnivel y ocultas no están diseñadas para soportar 
el peso de este producto. Los productos para montar en cielorraso de Oberon tienen cuatro pestañas para cable de soporte en la caja posterior. Estas pesta-
ñas deben utilizarse para sujetar el producto con cables independientes, cables de acero, varillas roscadas u otro medio de soporte seguro, de caliber adec-
uado y resistencia al fuego.

 

2. Al cerrar la puerta de acceso al recinto, asegúrese de que el seguro de leva esté completamente trabado para evitar que la puerta de acceso se abra por 
accidente.

 

3. Al abrir la puerta de la cubierta, asegúrese de sostener la puerta para evitar que se abra por accidente.

 

4. Esta cubierta tiene un entorno máximo de funcionamiento de 55 °C (131 °F). La temperatura dentro de la cubierta no puede exceeder este valor, de-
pendiendo de la disipación de energía dentro de la misma.

 

5. Debe mantenerse un espacio mínimo de 1" entre la carcasa del punto de acceso y las paredes laterales de la cubierta para el funcionamiento seguro del 
equipo.

 

6. Este producto debe ser instalado por personal capacitado.

 

7. Solo productos homologados por ITE pueden instalarse dentro de la cubierta.

 

8. Este producto debe ser reparado por personal capacitado por el fabricante o devuelto al fabricante para su reparación o reemplazo.

 

9. El peso máximo a instalar en la unidad es de 25 libras.

 

10. Todos los perforados, las aberturas y los orificios deben sellarse con un tapón de metal o de un material no metálico que cumpla con las normas UL 2043 
o UL 1479.

 

11. Todos los orificios de montaje sin usar deben sellarse con cinta u otro material que cumpla con la norma UL 1479.

 

12. Dentro de la cubierta no debe utilizarse corriente alterna.

 

13. Se deberá incorporar un dispositivo de desconexión fácilmente accesible en el cableado de la instalación del edificio.

 

14. Consulte el plano de instalación aprobado por OSHPD donde corresponda.

 

Important code and installation information. 

/ Información im-

portante sobre normas e instalación.

 

Product Web Page 

/ Página Web del Producto

 

 

Отзывы: