INSTALLATION GUIDE
PAGE
HIGH DENSITY 5-DEGREE
BALLAST RACKING SYSTEM
13
In solar arrays, at the outer edge of the array often a single Base is clamped to two PV modules on one row and a single PV module on the opposite row, creating
a stepped edge. Clamps securing a single PV module are positioned differently than Clamps securing two PV modules. Follow the Clamp positioning instructions
below:
INSTALLATION OF CLAMPS FOR STEPPED ARRAY
Example of one confi guration of Stepped Array.
At array edge, South Row has one less PV module than North
Row, creating a stepped edge. Alternatively, Stepped Arrays may
have the single PV module on the North Row.
Stepped Array Edge
Clamp secures single PV module
Clamp secures two PV modules
STEPPED ARRAY INSTALLATION