Unique UGP 6C CR Скачать руководство пользователя страница 3

NOTICE TO INSTALLER/CUSTOMER

PLEASE READ CAREFULLY BEFORE HOOK-UP!

1.  The dwelling must have an adequate air supply and access to fresh air/oxygen in order to operate safely. 

Propane fridges/freezers, like any other gas appliance, must have access to fresh air/oxygen. This unvented 

appliance must not be used in an air-tight application.

2.  This refrigerator must be installed by a licensed gas fitter.
3.  The propane gas supply pressure regulator must be set at 11” water column.
4. The left side heat shield (facing front of the refrigerator) must be installed. The heat shield is shipped in the 

refrigerator carton attached to the fridge.

5.  The safety and efficient operation the proper clearances on all sides and top must be maintained. The 

clearances are listed in the Owner’s Manual.

6.  The proper and efficient operation the refrigerator must be level, both side to side and front to back (use 

bubble type level).

7.  The Combination Carbon Monoxide (CO) Alarm & Safety Shut-Off must be installed and connected (CM 

Models only) with the Alarm mounted as indicated in the Carbon Monoxide Alarm (Monitor) Installation Manual 

located in the CO Monitor Box.

 NOTE: 

It is illegal to operate this refrigerator in Canada without the Combination Carbon Monoxide 

Alarm & Safety Shut-Off installed, and will void the Canadian standards Association Certification. Non 

compliance will void the Canadian certification and void household/cottage insurance coverage.

 This 

refrigerator vents combustion products directly into the living space. The CO Alarming Device with Safety 

Shut-Off has been added to this refrigerator to guard against potentially high levels of Carbon Monoxide, 

which can kill you. Once unsafe levels of CO are detected, an alarm will sound and the refrigerator will be shut 

off.

 

WARNING: 

Actuation of this device indicates the presence of unsafe levels of carbon monoxide (CO) which 

can KILL YOU. If alarm signal sounds:

a.  Immediately move to fresh air - outdoors or by an open door or window. Check that all persons are accounted 

for. Do not re-enter the premises or move away from the open door/window until the emergency services 

responders have a,rived, the premises have been aired out, and your alarm remains in its normal condition;

b.  Call emergency local service telephone number, fire department or 911.
c.  The following symptoms may be related to CARBON MONOXIDE POISONING and should be discussed with 

ALL members of the household:

  Mild Exposure: Headaches, running nose, sore eyes, often described as “flu”-like symptoms;
  Medium Exposure: Dizziness, drowsiness, vomiting;
  Extreme Exposure: Unconscious, brain damage, death.
d.  Read the instructions for complete information on Alarms Signals.
8.  Regular maintenance of the fridge critical to prevent unsafe levels of Carbon Monoxide.
  Before lighting the refrigerator at any time, clean the flue tube as per the Owner’s Manual & make sure the 

burner and areas around the burner are free from any lint, spider webs or any other debris. Please record your 

appliance maintenance on the SERVICE RECORD label located at the back of your appliance.

  WARNING - Test the Combination Carbon Monoxide & Safety Shut-Off device operation after the refrigerator 

has been in storage, before each start up, and at least once per week during use.

Unique Appliances Ltd., 

2245 Wyecroft Road #5, Oakville, Ontario, Canada L6L 5L7

Tel: 905-827-6154 - Toll Free: 1-877-427-2266 - Email: [email protected]

www.UniqueAppliances.com

3

Содержание UGP 6C CR

Страница 1: ...IDE serial number UGP 6C 8C 10C 14C 14C CR PROPANE FRIDGE CLASSIC RETRO BY UNIQUE 14 CU FT PROPANE FRIDGE 14 CU FT PROPANE FRIDGE 10 CU FT PROPANE FRIDGE 8 CU FT PROPANE FRIDGE 6 CU FT PROPANE FRIDGE...

Страница 2: ...ersonal injury or death WARNING CARBON MONOXIDE POISONING MAY CAUSE DEATH OR INJURY When used without adequate combustion and ventilation air the refrigerator may give off excess CARBON MONOXIDE and o...

Страница 3: ...entially high levels of Carbon Monoxide which can kill you Once unsafe levels of CO are detected an alarm will sound and the refrigerator will be shut off WARNING Actuation of this device indicates th...

Страница 4: ...ely committed to providing you with the best service possible Your satisfaction is our 1 priority Please read this manual very carefully It contains valuable information on how to properly maintain yo...

Страница 5: ...stallation of the appliance must conform with local codes or in the absence of local national Fuel Gas Code ANSI Z233 1 and in Canada B149 2 WARNING The California Safe Drinking Water and Toxic Enforc...

Страница 6: ...rigid gas supply connector the refrigerator should be located with sufficient space at the back for servicing or if located against a wall a removable panel of a minimum size of 16 x 20 should be pro...

Страница 7: ...e leak detector and or soap and water for a bubble check WARNING DO NOT USE FLAME TO CHECK FOR GAS LEAKS The gas supply system must incorporate a pressure regulator to maintain a supply pressure of no...

Страница 8: ...ot cover recharge rebuild if caused by not running the fridge level THIS REFRIGERATOR OPERATES ON LP GAS PROPANE 110V ELECTRICITY Note After changing an LP tank or after a long shut off period the gas...

Страница 9: ...plugged into a grounded outlet 2 Turn the selector switch G to AC position AC power indicator F will illuminate 3 To start the refrigerator turn the thermostat knob E to maximum setting Adjust the th...

Страница 10: ...acts as an insulator and adversely affects the refrigerator performance Check the formation of frost every couple of weeks and when it exceeds 1 2 thick or more defrost the refrigerator Shut off and e...

Страница 11: ...cated at the back of the appliance To change the batteries use the following procedure 1 Go to the back of the appliance and pop off black cover 2 Remove and replace the 4 x AA batteries 3 Pop the bla...

Страница 12: ...rating effectively and safely periodic inspection and cleaning of several components is recommended once or twice a year sometimes more often depending on the environment It s important to keep the ar...

Страница 13: ...ith compressed air Re install and tighten burner orifice Replace burner WARNING DO NOT use a pin or wire when cleaning the burner orifice as damage can occur to the precision opening This can cause da...

Страница 14: ...er dirty Clean See Section MAINTENANCE SERVICE PERIODIC MAINTENANCE 8 LP gas pressure low at the burner Regulator pressure must not drop below 11 inches W C water column GAS CONNECTION 9 Burner not lo...

Страница 15: ...ddle hinge in top hole of fridge door and using the Phillips screwdriver fasten the middle hinge in place using the screws you previously removed 9 Now place the freezer door on top of the middle hing...

Страница 16: ...he cooling fins and try to maintain a temperature of 38 F or 4 C in the fridge NOTE When first turning the refrigerator on move refrigerator controls to maximum which is the recommended initial settin...

Страница 17: ...Avoid storing hard to freeze foods such as ice cream and orange juice on the freezer door shelves These foods are best stored in the freezer interior where the temperature varies less CARE AND CLEANIN...

Страница 18: ...22 Parts Diagram and Lists UGP 6C 8C 10C UGP 6C 18 UGP 6C PARTS DIAGRAM LIST...

Страница 19: ...njector UGP DL10001713 45 Burner assembly UGP DL6810V3CONKIT No Item Code 45 1 Burner bracket UGP DL22502507 45 2 Burner tube support UGP DL10001476 46 Burner tube UGP DL10001142 47 Burner cover assem...

Страница 20: ...UGP 8C 20 UGP 8C PARTS DIAGRAM LIST...

Страница 21: ...Connector UGP DL10001501 43 4 Washer UGP DL00009306 43 5 Screw UGP DL22501206 44 Injector UGP DL10001713 No Item Code 45 Burner assembly UGP DL6810V3CONKIT 45 1 Burner bracket UGP DL22502507 45 2 Bur...

Страница 22: ...23 UGP 8C UGP 10C 22 UGP 10C PARTS DIAGRAM LIST...

Страница 23: ...L00009306 43 5 Screw UGP DL22501206 44 Injector UGP DL10001713 No Item Code 45 Burner assembly UGP DL6810V3CONKIT 45 1 Burner bracket UGP DL22502507 45 2 Burner tube support UGP DL10001476 46 Burner t...

Страница 24: ...32 83 84 85 86 87 88 89 90 91 92 93 94 95 56 58 57 59 60 61 62 63 64 65 66 67 70 71 69 68 78 77 76 75 74 44 43 42 41 40 39 38 37 36 35 34 33 45 46 47 48 49 50 51 52 53 54 55 73 72 79 80 81 82 82 2 82...

Страница 25: ...er UGP DL38801110 50 Baffle UGP DL27501007 51 Front Platform UGP DL38801032 No Item Code 52 Rear Platform UGP DL38801033 53 Power cord UGP DL10001252 54 Thermocouple wire UGP DL22501254 55 Connection...

Страница 26: ...2 23 24 25 26 27 28 29 30 31 32 83 84 85 86 87 88 89 90 91 92 93 94 95 56 58 57 59 60 61 62 63 64 65 66 67 70 71 69 68 78 77 76 75 74 44 43 42 41 40 39 38 37 36 35 34 33 45 46 47 48 49 50 51 52 53 54...

Страница 27: ...l burner brush UGP DL27501318 No Item Code 49 Baffle holder UGP DL38801110 50 Baffle UGP DL27501007 51 Front platform UGP DL38801032 52 Rear platform UGP DL38801033 53 Power cord UGP DL10001252 54 The...

Страница 28: ...r 9RV SSO C M2 QMP Interrupter Block Interrupter Block for CO Monitored fridges M3 QMP Mosfet C Mosfet Assembly for CO Monitored Models CO Monitor and Components all units M1 M2 M3 28 CO MONITOR UGP 9...

Страница 29: ...tees express or implied made or intended by Unique or its authorized distributors and all other warranties conditions representations or guarantees including any warranties conditions representations...

Страница 30: ...al costs of removal and or installation of the Product or any other incidental costs which may arise as a result of any defect in material or workmanship and e upon discovery of defect Buyer shall imm...

Страница 31: ...servicing of your fridge easy and efficient please record the following information for future reference CONTACT US Toll free 1 877 427 2266 or 905 827 6154 available during regular business hours 8 3...

Страница 32: ...2021 Unique Appliances Ltd 2245 Wyecroft Road 5 Oakville Ontario Canada L6L 5L7 www uniqueappliances com...

Отзывы: