22
To convert application and/or adjust from NG to LPG
The range is set for use with Natural Gas (NG). The factory setting is indicated on
the serial plate. When set for Natural Gas operation, the pressure regulator will
regulate the gas to 5 inches water column pressure. When set for Liquid Propane
Gas (LPG) operation, the pressure regulator will regulate the pressure to 10 inches
water column.
Natural Gas to Liquid Propane Gas Conversion
The conversion kit must be installed by qualified service agency.
WARNING:
Please ensure before beginning converting the appliance that the gas
supply is shut off and the electrical connection is disconnected. Failure to do can
result in injury or property damage.
GAS RANGE CONVERSION
“This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer’s instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explosion or production of
carbon monoxide may result in property damamge, personal injury or loss
of life. The qualified service agency is responsible for the proper installation
of this kit. The installation is not proper and complete until the operation
of the converted appliances is checked as specified in the manufacturer’s
instructions supplied with the kit.”
ATTENTION: YOUR PRODUCT IS PRE-INSTALLED WITH NATURAL GAS
INJECTORS AND REGULATOR.
IF YOU ARE USING LP GAS, PLEASE REFER TO THE INSTALLATION
INSTRUCTIONS INCLUDED WITH THE CONVERSION KIT.
Natural Gas Orifices
BTU
2,700
5,000
11,000
8,500
7,000
8,200
BURNER
Auxiliary
Burner
Semi-Rapid
Burner
Triple Burner Rapid Burner Broil Burner
Oven Burner
POSITION
Front Right
Back Left
Back Right
Front Left
ORIFICE
0.73
1.0
1.5
1.3
1.24
1.3
Liquid Propane Gas Orifices
BTU
2,700
5,000
11,000
8,500
7,000
8,200
BURNER
Auxiliary
Burner
Semi-Rapid
Burner
Triple Burner Rapid Burner Broil Burner
Oven Burner
POSITION
Front Right
Back Left
Back Right
Front Left
ORIFICE
0.53
0.68
1.0
0.9
0.8
0.82