Your Unique freezer, like any battery-powered refrigerating appliance, requires diff erent care 

than appliances plugged into an electric utility. Prudent operation is the key to extended service.

STARTING THE FREEZER 

After the freezer has been properly connected to the 12V or 24V DC power source, the 

compressor will automatically turn on and the cabinet will begin cooling. Allow the cabinet to cool 

for at least 4 hours prior to adding foodstuff .

TEMPERATURE CONTROL

The temperature within the freezer compartments is controlled by the 

thermostat situated on the top of the freezer area. When you fi rst start the 

freezer we suggest that you turn the thermostat to a maximum setting until 

desired freezer temperatures are achieved. The correct internal temperature 

setting can be found by measuring the temperature of the central or middle 

portion in the appliance.

NORMAL OPERATING TEMPERATURE RANGE 

(in the ambient 25˚C / 77˚F)

THERMOSTAT SETTING

FREEZER TEMPERATURE

*Optimal Setting = 1.6

-10˚C to -15˚C / 14˚F to 5˚F

Setting = 4

-25˚C / 5˚F

NOTE: 

Setting 1 being the warmest and 4 the coldest

*NOTE:

 Mechanical temperature controller has a + or - 0.5 range. The freezer will run a few 

degrees colder at high elevations.

ADJUSTMENTS

As the ambient temperature changes with the season, it may be necessary to adjust the thermostat 

to achieve the proper internal temperature. If the room/ambient temperature approaches the 

appliance’s internal operating temperature, the appliance will not function as it should. The 

appliance will tend to run colder during these conditions and it may be necessary to turn the 

thermostat to a warmer setting (lower number). If the room/ambient temperature exceeds 100˚F 

(38˚C), the appliance will not function as it should. The appliance will tend to run warmer and it 

may be necessary to turn the thermostat to a colder setting (towards the maximum setting).

OPENING AND CLOSING THE DOOR

The doors are fi tted with uniform sealing strips to prevent warm air and moisture from entering the 

freezer compartments. Be sure that the doors and door seals are free from obstructions and form 

a complete seal around the rim of the freezer cabinets. Over stuffi

  ng and/or unlevel installation 

of the appliance will prevent a good seal. It might be hard to open the door immediately after the 

door is closed. This is due to air contraction in the freezer cabinets. This pressure diff erence will 

equalize in a few seconds, making the doors easy to open once again.

OPERATION

Содержание Classic UGP-175L UR W

Страница 1: ...OWNER S GUIDE serial number 175L 6 1 cu ft UPRIGHT SOLAR DC FREEZER MODEL NUMBER UGP 175L UR W NOV20V2 ...

Страница 2: ... assistance Before you call for service here are a few things you can do to help us serve you better Read this owner s manual It contains instructions to help you use and maintain your appliance properly Visit out website Our website www UniqueAppliances com will give you access to self service tools FAQs and much more If you receive a damaged appliance Immediately contact the retailer that sold y...

Страница 3: ... ability to cool larger warm loads as quickly as typical AC powered appliances These warnings are provided in the interest of your safety Please ensure that you understand them all before installing or using this freezer Your safety is of paramount importance If you are unsure about any of these meanings or warnings contact your local product dealer or Unique Appliances for assistance PRIOR TO INS...

Страница 4: ...id the warranty It is dangerous to make alterations or attempt to modify this product in any way Product alterations will void the warranty DURING USE This appliance is designed for domestic use only specifically for the storage of food and drinks This appliance is not designed for commercial or industrial use Do not store any containers with flammable vapors or liquids in or around the appliance ...

Страница 5: ...y circumstances A sponge soft brush or towel is recommended After cleaning thoroughly rinse and dry You may want to leave the doors open allowing the compartments to ventilate for 20 30 minutes to get rid of residual odors Check with your local Environmental Agency for recommendations on recycling packaging materials in your area POSITIONING THE APPLIANCE The area in which the fridge is to be inst...

Страница 6: ...FEATURES PARTS LIST 1 Storage drawers 2 Thermostat 3 Door 4 Adjustable feet 5 Ice tray 6 Power cable 7 AC DC Plug sold separately for 110V application AC DC Plug sold separately for 110V application 1 2 3 4 5 6 7 ...

Страница 7: ...ED TO MAKE ANY ADJUSTMENT ATTENTION Polarity is important in wiring this DC appliance Be sure that the positive terminal of the battery or charge controller coincides with the positive wire to the compressor and the negative terminal of the battery or charge controller coincides with the negative wire to the compressor The leads should be connected using cable shoes and screwed connections Joined ...

Страница 8: ...nce does not drop below the cut out voltage of the compressor CABLE SIZE 12V CABLE LENGTH 24V CABLE LENGTH AREA AWG mm2 inch Gauge m ft m ft 2 5 3 32 12 2 5 8 5 16 4 5 32 12 4 13 8 26 6 15 64 10 6 19 5 12 39 10 25 64 8 10 32 8 20 65 6 LOW VOLTAGE DISCONNECT The compressor electronics includes a low voltage disconnect feature If the input voltage to the appliance falls below 10 4V in 12V mode or 22...

Страница 9: ... 5 range The freezer will run a few degrees colder at high elevations ADJUSTMENTS As the ambient temperature changes with the season it may be necessary to adjust the thermostat to achieve the proper internal temperature If the room ambient temperature approaches the appliance s internal operating temperature the appliance will not function as it should The appliance will tend to run colder during...

Страница 10: ...ounds when the refrigerant is being pumped through the refrigerant coils When the compressor is on the refrigerant is being pumped through the appliance and you will hear a whirring or pulsing sound from the compressor A thermostat controls the compressor and you may hear a click when the thermostat cuts in and out DEFROSTING Before cleaning or repositioning the freezer you must DISCONNECT the app...

Страница 11: ...ror code or LED flashes Error Type Can be read out in the TOOL4COOL software 6 Thermostat failure If the NTC thermistor is short circuit or has no connection 5 Thermal cut out of electronic unit If the refrigeration system has been too heavily loaded or if the ambient temperature is high the electronic unit will run too hot 4 Minimum motor speed error If the refrigeration system is too heavily load...

Страница 12: ...an the freezer as it may cause damage to the surfaces Do not install the freezer close to sources of heat such as a stove boiler heater chimney etc and avoid exposure of the appliance to direct sunlight Locate the appliance in a cool well ventilated room and make sure that the air vents of the compressor housing cover are not obstructed Also allow adequate spacing around the cabinet for air circul...

Страница 13: ...o it will take some time for the appliance to return to temperature Does the cabinet have adequate ventilation around the side walls allowing it to transfer heat properly See Installation section The door will not open Has the door just been opened If so leave the appliance closed for a few minutes to allow the air pressure to equalize and try again Excessive frost and ice has built up Is the weat...

Страница 14: ...14 PARTS DIAGRAM LIST ...

Страница 15: ... left 15 UGP 175L 15 Upper drawer 16 UGP 175L 16 Door seal 17 UGP 175L 17 Upper strongback hinge cover 18 UGP 175L 18 Door 19 UGP 175L 19 Handle 20 UGP 175L 20 Hexagon cone screws 21 UGP 175L 21 Aided sucker apparatus 22 UGP 175L 22 Bottom drawer 23 UGP 175L 23 Adjustable foot 24 UGP 175L 24 Low adjustable foot 25 UGP 175L 25 Compressor base 26 UGP 175L 26 Flange screw 27 UGP 175L 27 Trouble light...

Страница 16: ...rranty does not apply to any appliance that has been subjected to alterations misuse abuse including damage by foreign agents or chemicals accident improper installation or service delivery damage or other than normal household use and service This UNIQUE appliance must be serviced regularly as outlined in the Owner s Manual Neither Unique Appliances Ltd nor the selling dealer will be liable for d...

Страница 17: ...apply when damage or repair is caused by any of the following 1 Power failure 2 Damage in transit or when moving the appliance 3 Improper power supply such as low voltage defective house wiring or inadequate fuses 4 Accident alteration abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions ie extremely high or low room temperature 5 Use for...

Страница 18: ... 102 5 lbs 46 5 kg DC Power 12V 24V Total Watt Hr Pull Down 24 DC 695 Wh 24hrs set to 13 C freezer performance in a 25 C ambient Total Watt Hr Stable Running 24 DC 532 Wh 24hrs set to 13 C freezer performance in a 25 C ambient Power Consumption 12V 24V 58 8 W Average Run Current 4 9A on 12V 2 5A on 24V Freezer Temp Range 6 C to 25 C TECHNICAL SPECIFICATIONS ...

Страница 19: ...oll free 1 877 427 2266 or 1 905 827 6154 available during regular business hours 8 30 am to 4 30 pm EST Website www uniqueappliances com Email info UniqueAppliances com Please visit our website at https uniqueappliances com product registration to register your product To make care and servicing of your fridge easy and efficient please record the following information for future reference Model S...