10
Frost Prevention of Indoor Unit
When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coil
temperature is lower than 0°C at the end of 10 minutes of continuous compressor operation from the start, the
microcomputer of the unit stops the compressor to protect the unit from the frost. The control procedure for
indoor coil freeze protection.
1) The compressor and outdoor fan turn off.
2) Indoor fan operates according to user set speed.
3) The normal operation returns when the indoor coil
temperature is higher than 7°C or equal to 7°C.
-1
°
C
+7
°
C
Compressor and
Outdoor Fan
ON
ON
OFF
Indoor Fan
Set speed
(Indoor coil temperature)
Auto Mode
(1) In Auto Mode
After the indoor fan is operated for 20 seconds in the Auto Mode the unit will operate automatically by selecting
operating Mode according to the room temperature
(2) Selecting Operating Mode Again
• In case of operating mode is Cooling : room temperature meets
Heating range(DT-2°C > RT) at the end of 10 minutes of continuous compressor stop, then the unit select
operating mode again.
The unit will automatically by Heating mode.
• In case of operating mode is Heating or Dehumifier : room temperature meets
Cooing range(RT+3°C < RT) ----------------------------> Cooing mode
(3) Range of setting temperature: 22~26°C
3 min. Time Delay of Compressor
In normal operation, there is a time delay of three minutes between turn off and turning back on including initial
power up.
ROOM TEMPERATURE
DT-2°C RT
DT-2°C
≤
RT
≤
DT+3°C
DT+3°C RT
OPERATING MODE
Cooling
Dehumidifier
Cooling
(RT: Room temperature)
>
<
0°C
Содержание DPA-246LG
Страница 2: ...FLOOR STANDING TYPE Air Conditioner Model DPA 246LR DPA 246LG ...
Страница 16: ...14 2 DPA 246LR LGINDOORUNITOUTLINEANDSECTION ...
Страница 19: ...17 1 INDOORUNIT 4 WIRING DIAGRAM ...
Страница 20: ...18 2 OUTDOORUNIT ...
Страница 22: ...20 1 DPA 246LR LGINDOORUNIT 5 EXPLODED DIAGRAM ...
Страница 25: ...23 2 DPA 246LR LG OUTDOOR UNIT ...
Страница 31: ...29 8 PCB DRIVING DESCRIPTION 1 DPA 246L R G INDOOR UNIT MAIN PCB CIRCUIT ...
Страница 32: ...30 2 DPA 246L R G INDOOR UNIT FRONT PCB CIRCUIT ...
Страница 33: ... 3 DPA 246L R G OUTDOOR UNIT PCB CIRCUIT ...
Страница 43: ...SPLIT TYPE Air Conditioner Model DSA 0910LR M DSA 0910LG M ...
Страница 46: ...3 2 OUTLINE AND DIMENSIONS 1 INDOOR UNIT DSA 0910LR G M ...
Страница 56: ...13 4 WIRING DIAGRAM Indoor Unit DSA 0910LR G M ...
Страница 59: ...16 6 CONTROL BLOCK DIAGRAM DSA 0910LR G M ...
Страница 66: ...23 PCBDRIVINGDESCRIPTION ...
Страница 67: ...24 1 PCB CIRCUIT DIAGRAM DSA0910LR G M ...
Страница 76: ...33 3 EXPLODED DIAGRAM Indoor Unit DSA 0910LR G R ...