9.OPTION (Option card required)
142
9-3-7. AO lower limit
This menu item specifies the lower limit value for AO output. If floating decimal place
modes (e.g. other than “4mA OUTPUT” and “20mA OUTPUT”) are selected in [AO
OUTPUT MODE], the zero and full-scale range is set to 0 – 100%, and any value
below zero is fixed to 4mA. AO lower limit values are set separately for each channel.
This function is disabled if you enter 0.00%. [AO LOWER LIMIT] cannot be greater
Operation
than [AO UPPER LIMIT].
9-3-8. AO upper limit
This menu item specifies the upper limit value for AO output. If floating decimal place
modes (e.g. other than “4mA OUTPUT” and “20mA OUTPUT”) are selected in [AO
OUTPUT MODE], the zero and full-scale range is set to 0 – 100%, and any value
above the full-scale is fixed to 20mA. AO upper limit values can be set separately for
each channel.
This function is disabled if you enter 100.00%. [AO LOWER LIMIT] cannot be greater
than [AO UPPER LIMIT].
Operation
Input range: 0– 100.00% (5 digits, decimal place fixed )
MODE
→
AO LOWER LIMIT
PAGE
→
OPTION
→
Cur
rent [
m
A
]
0
25
50
75
100
Calculated value
Output [%]
Lower limit 0.00%, upper limit 100.00%
Lower limit 10.00%, upper limit 80.00%
4
8
12
16
20
AO zero output
AO full-scale
Input range: 0– 100.00% (5 digits, decimal place fixed )
MODE
→
AO UPPER LIMIT
PAGE
→
OPTION
→