8.INTERFACE
129
8-4-9. Speed entry select
This menu item specifies the type of speed data entry.
For further information, see
"8-4-12.Pulse input entry procedure"
.
Operation
8-4-10. Pulse count/rotation
This menu item is effective only when “PHASE MEASURE” is selected in [SPEED
ENTRY SELECT], and specifies the number of pulses generated per a rotation of the
rotary encoder.
Operation
8-4-11. Fine-adjustment of D/A converter
The output level of the D/A converter can be adjusted by entering numbers from the
front display keypad. (This tuning procedure requires an external current meter:
connect the meter as the “external device” in the figure shown in
Operation
・
Password is required to enter the register screen
Options: NO, NORMAL MODE A, NORMAL MODE B, NORMAL A SLOW,
PHASE MEASURE, ANALOG CH1 MODE
*
, ANALOG CH2 MODE
*
,
* Selectable only when DAC and ANA options are installed.
MODE
OPTION
→
→
→
PAGE
SPPED ENTRY SELECT
→
PAGE
ANA. NORMAL A
*
, ANA. A SLOW
*
.
Input range: 1 – 99999 (5 digits, no decimal point)
MODE
OPTION
→
→
→
PAGE
PULSES / REVOLUTION
→
PAGE
MODE
PASS WORD
→
SYSTEM
1269
→
OK
→
→
1234
→
OK
→
→
PASS WORD
→
PAGE
Содержание F805AT-BC
Страница 1: ...F805AT BC BELT SCALE CONTROLLER 15 Feb 2019 Rev 1 03 OPERATION MANUAL...
Страница 15: ...CONTENTS XIV M E M O...
Страница 202: ......