52
7
OPTION
52
OP
TION
Chapter
7
12 (0x000C) Return bus communication error count
The total number of CRC errors detected by slave is read.
13 (0x000D) Return bus exception error count
The total number of exception responses sent by slave is read.
14 (0x000E) Return slave message count
The total number of frames consistent in slave address is read.
15 (0x000F) Return slave No response count
The number of times of not sending a response back to frames consistent in slave address is read.
[Request]
Function
1
byte
0x08
Subfunction
2
byte
s
0x00, 0x0C
Data
2
byte
s
0x00, 0x00
[Response]
Function
1
byte
0x08
Subfunction
2
byte
s
0x00, 0x0C
Data
2
byte
s
CRC error count
[Request]
Function
1
byte
0x08
Subfunction
2
bytes
0x00, 0x0D
Data
2
byte
s
0x00, 0x00
[Response]
Function
1
byte
0x08
Subfunction
2
byte
s
0x00, 0x0D
Data
2
byte
s
Exception response count
[Request]
Function
1
byte
0x08
Subfunction
2
byte
s
0x00, 0x0E
Data
2
byte
s
0x00, 0x00
[Response]
Function
1
byte
0x08
Subfunction
2
byte
s
0x00, 0x0E
Data
2
byte
s
Self-address message count
[Request]
Function
1
byte
0x08
Subfunction
2
byte
s
0x00, 0x0F
Data
2
byte
s
0x00, 0x00
[Response]
Function
1
byte
0x08
Subfunction
2
byte
s
0x00, 0x0F
Data
2
byte
s
No response count
Содержание F331
Страница 1: ...OPERATION MANUAL 26MAY2014REV 1 02 DIGITAL INDICATOR F331 ...
Страница 79: ...70 8 SPECIFICATIONS 70 SPECIFICATIONS Chapter 8 8 2 Dimensions Unit mm ...
Страница 80: ...71 8 SPECIFICATIONS 71 SPECIFICATIONS Chapter 8 When the BCD output option is equipped Unit mm ...
Страница 81: ...72 8 SPECIFICATIONS 72 SPECIFICATIONS Chapter 8 When the D A converter option is equipped Unit mm ...
Страница 82: ...73 8 SPECIFICATIONS 73 SPECIFICATIONS Chapter 8 When the RS 485 option is equipped Unit mm ...
Страница 83: ...74 8 SPECIFICATIONS 74 SPECIFICATIONS Chapter 8 When the RS 232C option is equipped Unit mm ...