4.0   SAFETY & INDUSTRY STANDARDS

4.1

 

DPBF1U & DPGF1U Series power distribution panels meet the following safety requirements: 

  

STANDARD

  UL60950-1, 2nd Edition
 

 

CSA22.2 No. 60950-1, 2nd Edition

 

 

EN60950-1, 2nd Edition

4.2

 

DPBF1U & DPGF1U Series power distribution panels are CE marked to indicate conformance 

to the European Union’s Low Voltage Directive.

4.3

 

These Distribution Panels operate at voltages that could potentially be hazardous.  

Furthermore, inadvertent short circuiting of the system battery and/or rectifier by mis-

connection or other error could be harmful.  This product should be handled, tested and 

installed only by qualified technical persons who are trained in the use of power systems 

and are well aware of the hazards involved.

4.4

 

When operating this Distribution Panels the chassis ground terminal must be connected to 
the system frame ground or other proper safety ground for the protection of personnel.

4.5

 

All connections to the Distribution Panels should be carefully checked for errors before 
applying power to them.

4.6

 

The internal voltages may be at hazardous potentials.  The top cover should not be removed.  
There are no user-serviceable components in these units. Removing the top cover will void 
the warranty.

5.0   WARRANTY (summary)

DPBF1U & DPGF1U Series power distribution panels are warranted for two (2) years from date of 

shipment against defects in material and workmanship.  This warranty does not extend to products 

which have been opened, altered or repaired by persons other than persons authorized by the 
manufacturer or to products which become defective due to acts of God, negligence or the failure 
of customer to fully follow instructions with respect to installation, application or maintenance.

For a complete text of UNIPOWER’s warranty conditions please request a copy from your local 

Sales Office.

Содержание DPBF1U Series

Страница 1: ...U DPGF1U SERIES Document Number DPBF DPGF MAN Rev 5 UNIPOWER LLC 65 Industrial Park Rd Dunlap TN 37327 Phone 1 954 346 2442 Toll Free 1 800 440 3504 Web site www unipowerco com 2019 UNIPOWER LLC All Rights Reserved P O W E R I N G T E C H N O L O G Y ...

Страница 2: ...1 0 INTRODUCTION 4 2 0 FEATURES OPTIONS 5 3 0 PRODUCT LINE 5 4 0 SAFETY INDUSTRY STANDARDS 6 5 0 WARRANTY summary 6 6 0 DESCRIPTION OF OPERATION 7 7 0 SPECIFICATIONS 8 8 0 CONFIGURATION 9 9 0 FRONT PANEL DESCRIPTION 11 10 0 UNPACKING AND INSPECTION 14 11 0 INSTALLATION 14 12 0 SETUP AND TESTING 15 REV DESCRIPTION CHK d APPR d DATE 5 PCO 45395 MM 07 31 19 ...

Страница 3: ...iagram 7 Figure 3 DPBF1U Front Panel View 11 Figure 4 DPGF1U Front Panel View 11 Figure 5 Input Bus Bar Detail 11 Figure 6 Output Barrier Strip Detail 12 Figure 7 Alarm Contact Ground Detail 13 Figure 8 Series Connection of Multiple Panels 14 TABLES Table 1 Basic Configurations 5 Table 2 LED State Definitions 7 Table 3 GMT Fuse Values 9 Table 4 Input Cable Lug Sizes Types 12 Table 5 Alarm Relay Co...

Страница 4: ...h existing rackmounted equipment Figure 1 shows the two series of panels The first is the DPGF1U Series which has 4 or 6 GMT fused circuits on both A and B sides The second is the DPBF1U Series with up to 4 circuit breaker circuits on both A and B sides NO C NC NO C NC B A T R T N 1 2 3 4 5 6 FA 1 5 6 B A T R T N 1 2 3 4 5 6 FA 1 5 6 DPGF1U GMT Fuse Distribution Panel NO C NC NO C NC ON I O OFF BA...

Страница 5: ...three standard options available Option C Clear plastic rear cover to protect connectors and wiring from damage This option will be supplied automatically unless it is specificially requested to be deleted Option S This option internally links the A bus to the B bus so that a fully configured unit can be supplied DC from a single feed TheAand B sides have the same voltage and polarity 3 0 PRODUCT ...

Страница 6: ... operating this Distribution Panels the chassis ground terminal must be connected to the system frame ground or other proper safety ground for the protection of personnel 4 5 All connections to the Distribution Panels should be carefully checked for errors before applying power to them 4 6 The internal voltages may be at hazardous potentials The top cover should not be removed There are no user se...

Страница 7: ...BATT BATT INPUT RET INPUT RET HI CURRENT BUS BAR HI CURRENT BUS BAR HI CURRENT BUS BAR HI CURRENT BUS BAR LOADS LOADS 1 2 3 N N 3 2 1 A SIDE ALARM CIRCUITS b SIDE ALARM CIRCUITS A SIDE B SIDE S OPTION S OPTION Figure 2 Block Diagram 6 2 Alarm Circuits The alarm circuits detect a tripped circuit breaker or blown and in this event turn on the red part of the LEDs The alarm circuits also each drive F...

Страница 8: ...ED Status Indication Green Normal Red Breaker Fuse Trip Open Alarm Off No Power Alarm Connections One Form C Relay Contact Per Bus SAFETY STANDARDS UL60950 1 2nd Ed CAS22 2 No 950 1 2nd Ed EN60950 1 2nd Ed ENVIRONMENTAL Operating Temp Range 10 C to 70 C Storage Temp Range 40 C to 85 C Humidity 0 to 95 Non Condensing PHYSICAL SPECIFICATIONS Case Material Steel Finish Powder Coat Black Dimensions In...

Страница 9: ...X 20A max 6 4 x 15A max 2 x 20A max Model DPGF1U A B NOTES 1 If section B is not used a blank panel is installed at the factory 2 The sum of all fuse currents on either side must not exceed the total rating GMT FUSES AMPS PART NUMBER COLOR 401 1500 0010 Red Order fuses separately UNIPOWER recommends Bussman fuses for this panel They may be ordered from UNIPOWER using the part numbers shown 401 150...

Страница 10: ...section B is not used a blank panel is installed at the factory The sum of all breaker currents on either side must not exceed the total rating When the S option is specified each side of the panel is limited to 75A total 150A Model No DPBF1U A B CODE AMPS F 1 G 2 5 H 5 I 10 J 15 K 20 L 25 M 30 STANDARD BREAKERS CODE OPTION C Front Cover Clear Plastic CODE VOLTAGE POLARITY 1 24 48V polarity neutra...

Страница 11: ... OFF ON I O OFF A SIDE B SIDE Alarm LED A A Side Breakers B Side Breakers Alarm LED B 1 2 3 4 1 2 3 4 Alarm Contacts A Input 20 Studs Ground 8 32 Stud B Outputs 6 32 Terminal Strip A Outputs 6 32 Terminal Strip B Input 20 Studs Figure 3 DPBF1U Front Panel View NO C NC NO C NC B A T R T N 1 2 3 4 5 6 FA 1 5 6 B A T R T N 1 2 3 4 5 6 FA 1 5 6 A SIDE B SIDE Alarm LED A A Side Fuses B Side Fuses Alarm...

Страница 12: ...0150 Table 4 Input Cable Lug Sizes Types 9 4 Output Connections Output connections for A and B loads are shown in Figure 6 There are 10 sets of barrier terminal strip connections for each side A and B The connections are numbered to correspond with the numbers of the front panel breakers The upper strip connections are from the battery through the breakers the lower strip connections are the retur...

Страница 13: ...act of side B and ALM A is for the Form C relay contact of side A The terminals viewed from left to right are the normally open NO common C and normally closed NC contacts respectively See table 5 below PIN FUNCTION CONTACT SCHEMATIC NC N C normally closed RELAY CONTACTS OUTPUTS N C C N O C C common NO N O normally open Table 5 Alarm Relay Contacts Normally Closed and Normally Open are defined wit...

Страница 14: ...in either 19 or 23 inch racks by using the supplied reversible brackets Mount it from the front of the rack using the correct offsets to align with existing rack mounted equipment The bracket offsets are every quarter inch from front to back 11 2 Connections Input connections should be made with one or two terminal crimp type lugs using copper wire size from no 1 to 8 AWG depending on current and ...

Страница 15: ...sary to have loads connected to the panel for this testing 12 2 With the input power source off connect the input wires to the A side of the distribution panel Connect ground to the chassis ground terminal Insert all fuses into fuse holders or set all circuit breakers to on 12 3 Turn on the input power source The A side LED should be green If it is red one of the fuses is blown or a circuit breake...

Страница 16: ...ct support can be obtained using the following addresses and telephone numbers Corporate office UNIPOWER LLC 210 N University Dr Coral Springs FL 33071 United States Manufacturing facility UNIPOWER LLC 65 Industrial Park Rd Dunlap TN 37327 United States Manufacturing facility UNIPOWER Slovakia SRO ZLATOVSKA 1279 Business Center 22 91105 Trencin Slovakia Phone 1 954 346 2442 Toll Free 1 800 440 350...

Отзывы: