![Uniphone UD-60 Basic Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/uniphone/ud-60-basic/ud-60-basic_installation-and-programming-manual_4497009029.webp)
24
2.4 SYSTEM PROGRAM : Kind 1
To program the system parameter, class of service, priority, restriction and ring of system.
1
Enter Kind
Number
HOLD
0
1
Enter Item
number
2
6
5
6
or setting
password
**PGM VER 2.XX**
Welcome ISDK SET
LCD
screen:
4
Item
Description
Default
Instruction
00
01
Day/Night transfer type
0
0: Null (depends on K1 item1,2,60,95)
1: Only active system auto-day/night transfer
(not include the station service class)
2: Only active station day/night transfer
3: Auto day/night transfer for system &
station service class
Related programs: K1 item 02, 06, 07, 60, 63,95.
If Day/Night class of service is the same, only set
up K1 item 01 will be enough.
The priority of transfer:
A.
Manual daytime/
nighttime transfer type (K1 item 2)
B.
Monthly
Auto daytime/nighttime transfer type (K1 item
95)
C.
Weekly daytime/ nighttime transfer type
for holiday (K1 item 60)
D.
Daytime/nighttime
transfer type for break (K1 item 63)
E.
Auto
daytime/ nighttime transfer type (K1 item 1)
02 Manual night transfer type
0
0: Null (According to program kind 1 item 1,
60,63, 95)
1: Only active system night transfer
2: Only active station night transfer
3: Night transfer for system & station (The
parameter is same as function no.64)
03 Page prelude tone
0
0: No
1: Yes
Match to function no.161 to page the keyphone.
04 Page coda tone
05 Password of Nighttine transfer
4477
Set 4 digits code by using "0 – 9","*", "#".
If the setting value is "0", it is not need to input
the password when it will start the night transfer
(function no. 64) and call forwarding - CO to CO
(function no. 23)
06 Beginning time of day service class
0800
24-hour format (hhmm)
07 Ending time of day service class
1700
08 DTMF tone duration
80
60-9999 ms
The sending time of DTMF dialling can be
programmed.
09 CO recall time
210
(1-9999) x 10 ms
For call-waiting of analog CO line, match to
function no.95
10 CO flash time
28
(1-9999) x 10 ms
For analog CO line, match to function no.94