6. Maintenance
During maintenance, all installation and process specific safety instructions must be
observed before work can begin. Maintenance may only be carried out by trained
personnel. Following maintenance, the assembly must be leak tested before being
returned to service.
6.1.
Capillary cooler with filter
The wire mesh filter inserts can be steam cleaned or exchanged depending on the
level of contamination. The O-ring seals must also be carefully be checked for
damage and replaced if necessary.
Figure 6 : Capillary cooler with filter unit
1
Top section with O-ring NBR 43x3mm
4
Wire filter- fine mesh
2
Filter seat with O-Ring NBR 43x3mm
5
Wire filter – coarse mesh
3
Condensate collector with O-Ring NBR 45x3mm