3.5.3.1. Door opening time settings
◆
[ENTER]
[3]
[3]
◆
<Open Duration>
(00-30):03
Default setting: ‘03’ (unit: sec.)
This is used to set the door opening time after authentication is successful.
For the strike type, this means the door opening time. For the dead bolt type
or auto door, this time is not effective.
If this is set to ‘00’, the door is out of control, so it may be set to ‘00’ only for
the start/leave time period.
Once the setting is complete, press [ENTER] to move to the next setting.
3.5.3.2. Door status monitor
◆
[ENTER]
[3]
[3]
[ENTER]
◆
<Door Monitor>
[0/1=NO/2=NC]:0
Default setting: ‘0’
- ‘0’: NW – no check
- ‘1’: NO – Dead Bolt Type or auto door
(Lock monitoring is On when the door is locked)
- ‘2’: NC - Strike Type
(Lock monitoring is Off when the door is locked)
‘0’ is for no check, ‘1’ is for dead bolt type or auto door; ‘2’ is for strike type.
When this is set to ‘1’ or ‘2’, the door condition connected to the terminal is
sent to the server periodically.
Once the setting is complete, Press [ENTER] to move to the next setting.
3.5.3.3 Door open alarm settings
<Door Open Alarm>
(00-30):00
Default setting: ‘00’
The terminal checks if the door has been open for more than setting