79/108
6.5.12 Object 6064h: Position actual value
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
6064h
0
Position
demand
value
I32
RO
No
Tx PDO
This object indicates current position.
This position value indicates Encoder value connected to controller.
6.5.13 Object 6065h: Following error window
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
6065h
0
Following
error
window
U32
RW
Yes
No
5000
Set the range of Follow Error Value.
Information
This object can NOT be set while it’s ’Operation Enabled’ state. Please set after ’Operation
Disable’.
Please refer to
4.1 Drive Status Control.
If the value of Following error actual value is greater than the value of Following error window,
’0xFF03
-
Position Tracking Error’ or ’0xFF0F
-
Position Overflow Error’ alarm occurs and Drive
is in Fault state.
6.5.14 Object 6067h: Position window
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
6067h
0
Position
window U32
RW
Yes
No
0
∼
63
0
Set the range of Positioning value.
Information
This object can NOT be set while it’s ’Operation Enabled’ state.
Please set after ’Operation
Disable’.
Please refer to
4.1 Drive Status Control.