• Stops during movem
ent due to limit switch of operation direction goes to ON.
• Current position during movement goes out of Software Position Limit (607Dh).
4.5.4.2
Input next target position
Once commands to move to new target position during previous position movement still
operates, executes new target position movement command after completion of previous
position movement. So, if already inputs next target position at buffer, position movement
command can be executed immediately without time delay.
Figure 4-5: Next Set-Point.
At this time, the Status word of Set-Point Acknowledge (Bit 12) is going to be RESET of
Control word of New Set-Point (Bit 4) and it goes to RESET after completion of the previous
position movement command. Target Reached (Bit 10) goes to SET once all of the position
movements are completed.