4) Parameters for Lap Welding
Plate
thickness
t (mm)
Welding
position
Electrode
(mm)
Welding
current
(A)
Welding
voltage
(V)
Welding
speed
(cm/min)
Gas flow
(L/min)
1.2
A
1.0
80~100
18~19
45~55
10~15
1.6
A
1.0 ~ 1.2
100~120 18~20 45~55
10~15
2.0
A or B
1.0 ~ 1.2
100~130 18~20 45~55
15~20
2.3
B
1.0 ~ 1.2
120~140
19~21
45~50
15~20
3.2
B
1.0 ~ 1.2
130~160
19~22
45~50
15~20
4.5
B
1.2
150~200
21~24
40~45
15~20
5) Parameters for MAG
Material: Carbon steel
Gas: Ar+CO2 mixed gas (10
15L/min)
Welding condition
Junction
type
Plate
thickness
(mm)
Electrode
(mm)
Gap
g(mm)
Current (A)
Voltage (V)
Welding speed
(cm/min)
1.0
1.0
0
50
55
13
15
40
55
1.2
1.0
0
60
70
14
16
30
50
1.6
1.0
0
100
110
16
17
40
60
2.3
1.0 or 1.2
0
1.0 110
120
17
18
30
40
3.2
1.0 or 1.2
1.0
1.5 120
140
17
19
25
30
I- type
4.0
1.2
1.5
2.0 150
170
18
21
25
40