23
Grounding connection
The grounding connection to an earthed installation is obligatory for this model equipped with a RCD (differential
switch and circuit breaker) in these groups, the generator star point is generally connected to the machine’s earth by
employing the TN or TT distribution system, the differential switch guarantees protection against indirect contacts.
In the case of powering complex installations requiring or employing additional electrical protection devices,
the coordination between the protection devices must be verified
For the grounding connection, use the terminal
comply to local and /or current regulations in force for electrical
installations and safety.
Prestart check
Perform the required daily maintenance and any other periodic maintenance that is due(see Perkin’sowner’s manual).
For the maximum service life of engine, make a thorough inspection, Look for following items: oil leak, coolant leak,
fuel leak, loose bolts, and excessive dirt and /or grease. Remove any excessive dirt or grease buildup. Repair any
faults that were identified during inspection. Inspect the cooling system for cracks and loose clamps. Inspect the
alternator and accessory drive belt for cracks, breaks, and other damage. Inspect the wiring for loose connections and
for worn or frayed wires. Check the fuel supply, drain water for water separator. Check the oil level daily, put in the
recommended oil and Fuel.
Check all engine fluid’s daily!
Do not use gasoline.
gasoline will damage engine.
The unit is shipped with enough fuel to prevent air from
entering fuel system. Add fresh diesel fuel before starting.
(see engine operation instruction label for fuel
specifications)
Do not run fuel tank dry because air will enter fuel system
and cause starting problems. See engine manualon how to
bleed air from fuel system.
Diesel fuel filling port
• Tray Liners, shipping skids and some running
gears insulate the welding generator from the
vehicle frame. Always connect a ground wire
from the generator equipment grounding terminal
to bare metal on the vehicle frames as shown.
• Electrically join generator frame to
vehicle frame by metal-to metal contact
Содержание RazorWeld MS500
Страница 71: ...71 Section 9 Electric diagrams Circuit diagram for CS 501 wire feeder TIG remote control connector ...
Страница 72: ...72 Circuit diagram for LN 25P wire feeder adapter ...
Страница 73: ...73 Circuit diagram for engine control system ...
Страница 74: ...74 Circuit diagram for generator output welding power and auxiliary power ...
Страница 75: ...75 Circuit diagram for welding power source ...
Страница 76: ...76 Circuit diagram for welding power source ...
Страница 81: ...81 ...
Страница 82: ...82 ...
Страница 83: ...83 ...