73
Troubleshooting
If these solutions do not work then please contact Maxon customer support at
or (02) 8707 3000
Hardware Issues
Power LED does not work.
!
Please check if the power adapter is OK.
!
Please check that power adapter supports between 9 ~ 30 [VDC].
Link LED on RJ45 port does not work.
!
Please check whether the Ethernet cable is inserted correctly or not. Also check
the PC’s LAN card.
!
Please check whether the Ethernet cable is direct or cross connect. The Ethernet
cable must be a direct cable.
!
If you are connecting the to a cross over HUB then you should use a
cross over cable.
Link LED on RJ-45 port is always green but does not connect on Internet.
!
In this case, the connected PC’s LAN card supports only 10Mbps but PC OS
(Operating System) is set to 100Mbps. Please change the PC environment to
support 10Mbps.
Software Issues
I need to set a static IP address on a PC.
!
By default, the assigns IP addresses from a range of 192.168.0.50 to
192.168.0.100 using the DHCP server. To set a static IP address on a PC, you can
use an IP from the DHCP range of the which is not used by any other
device on the network. Also you need to assign the IP as the default
gateway on that PC. Each PC or network device that uses TCP/IP must have a
unique address to identify itself in the network. If the IP address is not unique to a
network, Windows will generate an “IP conflict error" message.
I need to set up a server connected to a .
!
To use a server like a Web, FTP or Mail Server, you need to know the port number
which is used by the respective server. For example, Port 80 (HTTP) is used for
Web; Port 21 (FTP) is used for FTP, and Port 25 (SMTP outgoing) and port 110
Содержание MA-2025-4G
Страница 2: ...4...
Страница 37: ...39 Figure 16 Digital I O Control Page...
Страница 62: ...64 Setting up a Unimax as a VPN Gateway or a VPN Client VPN Gateway Figure 56 VPN Gateway...
Страница 64: ...66 Figure 57 VPN Client L2TP over IPSec...
Страница 69: ...71 Figure 60 Port Forwarding Figure 61 System...