page 5
RACK POWER
U S E R I N S T R U C T I O N S
Operating Instructions and Specifications
1. Maximum total load current: 30 AMPS.
2. AC Mains operating voltage 120Vac/60Hz or 220Vac/50Hz single Phase,
Mains operating voltage of the device need to be specified upon order.
3. Eight power outlets on the rear panel, 4 pcs of Powercon AC outlet rated @ 20A 250Vac and 4 pcs of 3 prongs universal AC outlet rated @13A 250Vac.
4. The 8 AC outlets on the rear panel are able to sequentially power on or power down, the sequence delay interval is user-adjustable from 0.4sec to 5sec
via the trimpot on the front panel.
5. 8 LEDs on the front panel show status of each circuit.
6.
Large size of LED display for Input voltage and Output load current indication
7. Blue 32A 3 Contact High Current Straight Inlet and Outlet front Panel mount sockets for the ease and safety connection of the mains input power.
8. Use the Blue 32A 3 Contact High Current In-line Socket for mains input power cable connection (as figure-3).
(Figure-3)
Blue 32A 3 Contact High Current In-line Socket.
(Figure-4)
Blue 32A 3 Contact High Current In-line Plug.
9. Use the Blue 32A 3 Contact High Current In-line Plug for mains power link cable connection (as figure-4).
10. A 30A fast acting main circuit breaker for the device's power ON/OFF control and it also serve as current overload protection.
11. Press the POWER push button to initiate the sequence to turn on the outlets in order from CH1 to CH8 when sequencing on, and turn the outlets off in the
reverse order from CH8 to CH1 when sequencing off.
12. Dimensions: 2U rack mountable, 88mm (H) x 483mm (W) x 313mm (D)
13. Weight (N.W):6.2 KG
14. Power Consumption (No Load): 11 Watts