1. Maximum total load current: 30 AMPS.

2. AC Mains operating voltage 120Vac/60Hz or 220Vac/50Hz single Phase,

 

Mains operating voltage of the device need to be specified upon order.

3. Eight power outlets on the rear panel, 4 pcs of Powercon AC outlet rated @ 20A 250Vac and 4 pcs of 3 prongs universal AC outlet rated @13A 250Vac.

4. The 8 AC outlets on the rear panel are able to sequentially power on or power down, the sequence delay interval is user-adjustable from 0.4sec to 5sec 

    via the trimpot on the front panel.

5. 8 LEDs on the front panel show status of each circuit.

6.

 

Large size of LED display for Input voltage and Output load current indication

7. Blue 32A 3 Contact High Current Straight Inlet and Outlet front Panel mount sockets for the ease and safety connection of the mains input power.

8. Use the Blue 32A 3 Contact High Current In-line Socket for mains input power cable connection (as figure-3).

 (Figure-3) 

Blue 32A 3 Contact High Current In-line Socket.

 (Figure-4) 

Blue 32A 3 Contact High Current In-line Plug.

9. Use the Blue 32A 3 Contact High Current In-line Plug for mains power link cable connection (as figure-4).

10. A 30A fast acting main circuit breaker for the device's power ON/OFF control and it also serve as current overload protection.

11. Press the POWER push button to initiate the sequence to turn on the outlets in order from CH1 to CH8 when sequencing on, and turn the outlets off in the 

      reverse order from CH8 to CH1 when sequencing off.

12. Dimensions: 2U rack mountable, 88mm (H) x 483mm (W) x 313mm (D) 

13. Weight (N.W):6.2 KG 

14. Power Consumption (No Load): 11 Watts

Содержание RACK POWER

Страница 1: ...he proper and safe operation i i i i RACK POWER www unika com tw CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 INPUT VOLTAGE LOAD CURRENT SEQUENCE DELAY 2 0 3 0 4 0 1 0 SECONDS MAXIMUM LOAD AC 220V 50Hz MAX 30A LIN...

Страница 2: ...RACK POWER U S E R I N S T R U C T I O N S Important Precautions and Features 2 Front Panel 3 Rear Panel 4 Operating Instructions and Specifications 5 Connector And Plug Assembly 6 page 1...

Страница 3: ...c motors power supplies and power amplifiers of all kinds sequenced powering can avoid excessive inrush currents that cause circuit breakers to trip even though the steady state currents are not exces...

Страница 4: ...rent nd 4 High Current Outlet User can easily to use the plug figure 1 for safety connection to the 2 RACK POWER or other device 5 High Current Inlet User can use the connector figure 2 for safety con...

Страница 5: ...MAXIMUM LOAD 30A RACK POWER L N L N L N L N CH 5 CH 6 CH 7 CH 8 CH 1 CH 2 CH 3 CH 4 11 10 10 CH1 CH4 Power Outlets 3 prongs universal AC outlet rated 13A 250Vac 11 CH5 CH8 Power Outlets Powercon AC o...

Страница 6: ...ication 7 Blue 32A 3 Contact High Current Straight Inlet and Outlet front Panel mount sockets for the ease and safety connection of the mains input power 8 Use the Blue 32A 3 Contact High Current In l...

Страница 7: ...Live Hot L Ground G Live Hot L Ground G Neutral N Each set of RACK POWER includes 1 piece each of the input connector and output plug Please see the following drawings to assemble these connector and...

Страница 8: ......

Отзывы: