Important Precautions

Read all operating instructions before using this equipment.

To reduce the risk of electrical shock, do not open the unit. 

There is NO USER REPLACEABLE PARTS INSIDE. Please contact the 

UNIKA Service Department or your authorized dealer to speak to a qualified 
service technician.

DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. Operators of 

electronic equipment should in no way be in contact with water. 

Features

    Power sequencing is needed whenever various kinds of equipment must 
be powered up or down in groups, rather than all simultaneously. In audio 
systems, sequenced powering is often necessary to allow turn-on 
transients from low level amplifiers and processors to settle down before 
any power amps are turned on, because simultaneous powering would 
result in a loud, annoying, and potentially destructive “pop” reaching the 
speakers. And in any large system whose components present a large 
inrush load to the AC line (Including electric motors, power supplies, and 
power amplifiers of all kinds), sequenced powering can avoid excessive 
inrush currents that cause circuit breakers to trip even though the steady-
state currents are not excessive.

    The RACK POWER allows you to control the power up and down 
sequence in a system to minimize turn-on transients and the damage that 
they may cause, Sequencing power on also smooths out inrush currents. 

    The RACK POWER provides controlled power sequencing to 8 rear AC 

outlets, each outlet is delayed by a fixed amount that is determined by the 
front panel sequence delay control.

    The RACK POWER is also full-featured with fast acting breaker to protect 

your system, a front panel LED display gives you a constant read of AC line 
input voltage and output load current.

The RACK POWER is designed to sequence and protect a wide range of 

equipment from sensitive tube preamps to powered speakers, large 
displays, or digital systems, your equipment will sound and work better 
and live longer.

 

RACK POWER

U S E R   I N S T R U C T I O N S

 

CAUTION 

RISK OF  ELECTRIC SHOCK 

DO NOT OPEN

!

WARNING:

TO PREVENT FIRE OR SHOCK
HAZARD. DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR 
MOISTURE.

Содержание RACK POWER

Страница 1: ...he proper and safe operation i i i i RACK POWER www unika com tw CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 INPUT VOLTAGE LOAD CURRENT SEQUENCE DELAY 2 0 3 0 4 0 1 0 SECONDS MAXIMUM LOAD AC 220V 50Hz MAX 30A LIN...

Страница 2: ...RACK POWER U S E R I N S T R U C T I O N S Important Precautions and Features 2 Front Panel 3 Rear Panel 4 Operating Instructions and Specifications 5 Connector And Plug Assembly 6 page 1...

Страница 3: ...c motors power supplies and power amplifiers of all kinds sequenced powering can avoid excessive inrush currents that cause circuit breakers to trip even though the steady state currents are not exces...

Страница 4: ...rent nd 4 High Current Outlet User can easily to use the plug figure 1 for safety connection to the 2 RACK POWER or other device 5 High Current Inlet User can use the connector figure 2 for safety con...

Страница 5: ...MAXIMUM LOAD 30A RACK POWER L N L N L N L N CH 5 CH 6 CH 7 CH 8 CH 1 CH 2 CH 3 CH 4 11 10 10 CH1 CH4 Power Outlets 3 prongs universal AC outlet rated 13A 250Vac 11 CH5 CH8 Power Outlets Powercon AC o...

Страница 6: ...ication 7 Blue 32A 3 Contact High Current Straight Inlet and Outlet front Panel mount sockets for the ease and safety connection of the mains input power 8 Use the Blue 32A 3 Contact High Current In l...

Страница 7: ...Live Hot L Ground G Live Hot L Ground G Neutral N Each set of RACK POWER includes 1 piece each of the input connector and output plug Please see the following drawings to assemble these connector and...

Страница 8: ......

Отзывы: