PART I: INSTALLATION MANUAL
9
Technical specifications
Note:
the Output values are referred to comburent air temperature lower than 50°C
* NOTE ON THE BURNER WORKING SERVICE:
for safety reasons, one controlled shutdown must be performed every 24 hours of
continuous operation.
BURNER TYPE
TP90A
TP91A
TP92A
TP93A
Output
min. - max. kW
320-2300
480 - 2670
480 - 3050
550 - 4100
Fuel
Natural gas - GPL
Category metano
(see next paragraph)
Gas rate
metano
min. - max. (Stm
3
/h)
34 - 243
51 - 283
51 - 323
58 - 434
Portata GPL
min. - max. (Stm
3
/h)
11,9 - 86
17,9 - 100
17,19 - 114
21 - 153
Category GPL
I
3B/P
Power supply
230V 3~ / 400V 3N~ 50Hz
Total power consumption (fan motor excluded)
kW
0,5
Fan motor power consumption
kW
see fan ID plate
Protection
IP40
Operation
Progressive - Fully modulating
Pressure
(see Note 2)
Gas train 50
Ø
Valves
/
Gas connection
2” / Rp 2
Gas train 65
Ø
Valves
/
Gas connection
2”1/2 / DN65
Gas train 80
Ø
Valves
/
Gas connection
3” / DN80
Gas train 100
Ø
Valves
/
Gas connection
4” / DN100
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Intermittent
BURNER TYPE
TP512A
T515A
T520A
TP525A
Output
min. - max. kW
600-4.500
770 - 5.200
1.000 - 6.400
2.000 - 9.750
Fuel
Natural gas - GPL
Category metano
(see next paragraph)
Gas metano
min. - max. (Stm
3
/h)
63 - 476
81 - 550
106 - 677
212 - 1.032
Portata GPL
min. - max. (Stm
3
/h)
22 - 168
29 - 194
37 - 239
75 - 364
Power supply
230V 3~ / 400V 3N~ 50Hz
Category GPL
I
3B/P
Total power consumption (fan motor excluded)
kW
0,5
Fan motor power consumption
kW
see fan ID plate
Protection
IP40
Operation
Progressive - Fully modulating
Pressure
(see Note 2)
Gas train 50
Ø
Valves
/
Gas connection
2” / Rp 2
Gas train 65
Ø
Valves
/
Gas connection
2”1/2 / DN65
Gas train 80
Ø
Valves
/
Gas connection
3” / DN80
Gas train 100
Ø
Valves
/
Gas connection
4” / DN100
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Intermittent
Note1:
all gas flow rates are referred to Stm
3
/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 natu-
ral gas (net calorific value H
i
= 34.02 MJ/Stm
3
).
Note2:
Maximum gas pressure = 500mbar (with Siemens VGD gas valves / Dungs MBC gas valves).
Minimum gas pressure = see gas curves.
Note1:
All gas flow rates are referred to Stm
3
/ h (1.013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
(net calorific value H
i
= 34,02 MJ / Stm
3
); for L.P.G. (net calorific value H
i
= 93,5 MJ / Stm
3
)
Note2:
Maximum gas pressure = 360 mbar (with
Dungs MBDLE)
= 500 mbar (with
Siemens VGD or Dungs MultiBloc MBE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80 %