7
Technical specifications
*
NOTE ON THE BURNER WORKING SERVICE: for safety reasons, one controlled shutdown must be performed after 24 hours
of intermittent operation.
NOTE:
Choosing the nozzle for light oil, consider Hi equal to 42.8MJ/kg.
BURNERS
RG91
RG92
RG93
Output
min. -max. kW
698 - 2093
849 - 2558
550 - 4100
Light oil rate
min. -max. kg/h
59 - 176
72 - 215
46 - 345
Fuel
Light oil
Viscosity
cSt @ 40 °C
2 - 7.4
Density
kg/m
3
840
Oil train pressure inlet
bar max
4
Power supply
400V 3N ~ 50Hz
Fan motor
kW
4
5.5
7.5
Pump motor
kW
1.1
1.1
1.1
Total power consumption
kW
5.6
7.0
9.0
Index of protection
IP40
Approx. weight
kg
220
220
230
Operation
Progressive - Fully modulating
Operating temperature
°C
-10 ÷ +50
Storage temperature
°C
-20 ÷ +60
Working service *
Intermittent
BURNERS
RG510
RG515
RG520
RG525
Output
min. -max. kW
1314 - 3953
1628 - 4884
2326 - 6977
2000 - 8000
Fuel
Light oil
Light oil rate
min. -max. kg/h
111 - 333
137 - 411
196 - 588
169 - 674
Viscosity
cSt @ 40 °C
2 - 7.4
Density
kg/m
3
840
Oil train pressure inlet
bar max
4
Power supply
400V 3N ~ 50Hz
Electric motor
kW
7.5
11
15
18.5
Pump motor
kW
1.1
1.5
1.5
3
Total power consumption
kW
9.1
13
17
22
Operation
Progressive - Fully modulating
Index of protection
IP40
Operating temperature
°C
-10 ÷ +50
Storage temperature
°C
-20 ÷ +60
Working service *