![Unigas HP20 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/unigas/hp20/hp20_manual-of-installation-use-maintenance_842293029.webp)
C.I.B. UNIGAS
- M039203CC
29
Removing the combustion head
1
Remove the top
H
.
2
Disconnect the electrode cables
CE
.
3
Remove the
UV
detector out of its housing: disconnect electrode cables and the light oil flexible hoses.
4
Loosen the screws
V
holding the gas manifold
G
, loosen the two connectors
E
and remove the assembly as shown.
Note:
to replace the combustion head, reverse the operations described above.
5
Clean the combustion head by means of a vacuum cleaner; scrape off the scale by means of a metallic brush.