Installation
9
Test Installation
1. Connect the power cord to the wall outlet.
2. Place a battery in the charging slot.
3. A yellow LED indicates that charging starts while a green LED indicates a fully charged battery.
Install Multiple Units
NOTE: Maximum five units may be connected in a fixed electrical installation.
Any of the two terminal blocks can be used for AC input. The other is then used to connect the
next unit.
Figure 5
Units mounted and connected in a fixed installation (example)
Install First Unit
To install the first unit:
1. Remove the C14 connector from the power cord.
2. Measure, cut and strip the power cord.
3. Connect the power cord to the disconnect device.
The IEC color code is used in the power cord supplied.
Wiring color codes:
Install Additional Unit
1. Mount the additional unit to the wall.
2. Remove the top cover from the previous unit.
3. Remove the safety cover from the unused terminal block.
IEC
US
Old
*
*
The “Old“ standard was used in various countries (including Australia), and some wiring may still use these colours.
Load
Also called
Brown
Black
Red
Active
Line, Hot
Blue
White
Black
Neutral
Return, Cold, Grounded connector
Gr/Ye
**
** Gr/Ye - Green with Yellow stripe - this is the standard world wide, although it is not common in the US or Canada at
present.
Green
Green
Earth
Ground, Safety Earth, Earth Ground, Grounding
conductor
***
*** There is an important distinction between “Grounding conductor“ (safety earth) and “Grounded conductor“ (Neutral).
These are
US
terms for the conductors and they are
not
interchangeable, despite the similarity of the names !
To disconnect device
To disconnect device