Unify OpenStage WL3 Plus Скачать руководство пользователя страница 6

6

Installation

Regulatory Compliance Statements (USA/
Canada only)

FCC Compliance Statements for USA

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that in-
terference will not occur in a particular installation. If this equipment does cause harmful interfe-
rence to radio or television reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or more of the following measu-
res:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-

nected.

• Consult the dealer or an experienced radio/TV technician for help.

IC Requirements for Canada

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la Classe B conforme á la norme NMB-003 du Canada.

Modifications

Changes or modifications to the equipment not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment.

Installation

• A fixed electrical installation must be done by an authorized electrician.
• Maximum five units may be connected in a fixed electrical installation.
• The unit shall be placed in a dry environment with a temperature range from

+5° C to + 40° C (41° F to 104° F).

• The unit shall be mounted to a vertical wall.
• The unit shall be mounted to concrete or plaster walls only.
• Avoid mounting the unit in a sunlit place. This can affect the charging capacity.

Delivery Includes

• Battery Pack Charger
• Power cord including IEC C14 connector (male)
• Inlet accessory kit, including cable support holders and screws

A suitable extension cord is needed to connect a single unit to a wall outlet, unless the C14 con-
nector is replaced (by an electrician). The following item can be ordered from Siemens Enterprise 
Communications GmbH & Co. KG:

Item

Item Number

EU cord

L30280-Z600-F105

UK cord

L30280-Z600-F102

SWZ cord

L30280-Z600-F103

US cord

L30280-Z600-F101

Содержание OpenStage WL3 Plus

Страница 1: ...Battery Pack Charger OpenStage WL 3 OpenStage WL3 Plus Installation Guide A31003 M2000 J101 2 7631 ...

Страница 2: ...escriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract Availability and technical specifications are subject to change without notice Unify OpenScape OpenStage...

Страница 3: ...ompliance Statements EU EFTA only 5 Regulatory Compliance Statements USA Canada only 6 Installation 6 Mounting 7 Remove the Top Cover 7 Electrical Installation 8 Install Single Unit 8 Install Multiple Units 9 Operation 12 Charging 12 Battery Disconnection 12 Troubleshooting 12 ...

Страница 4: ...lled as a single unit Multiple Units A number of Battery Pack Chargers and Charging Racks may be connected together Maximum five units may be connected An installation with multiple units requires a fixed electrical installati on NOTE In the USA and Canada the Battery Pack Charger must only be installed as a single unit Connection of several units is not permitted Supply voltage 100 240VAC 0 7A 50...

Страница 5: ...ed near the equipment and shall be easily accessible In Sweden Norway and Finland the unit must be connected to protective earth safety grounding For other countries it is recommended to use a protective earth connection Suomi Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan Norge Apparatet må tillkoples jordet stikkontakt Sverige Apparaten skall anslutas till jordat uttag...

Страница 6: ... experienced radio TV technician for help IC Requirements for Canada This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la Classe B conforme á la norme NMB 003 du Canada Modifications Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Installation A f...

Страница 7: ...cal distance and to be able to open the top cover horizontal distance When you are planning the location of the units start to mount them in a height that makes it easy to reach the batteries 2 Measure and mark the drill holes by using the dimensions in Blue Figure 2 3 Drill and fasten the unit to the wall with four screws Figure 2 Mounting dimensions in mm Charging Rack seen from back Remove the ...

Страница 8: ...emoving the top cover Electrical Installation Install Single Unit NOTE It is not allowed to supply more than one unit by the power cord with the C14 connector Figure 4 IEC C14 connector and extension cord with IEC C13 connector ...

Страница 9: ...d in the power cord supplied Wiring color codes Install Additional Unit 1 Mount the additional unit to the wall 2 Remove the top cover from the previous unit 3 Remove the safety cover from the unused terminal block IEC US Old The Old standard was used in various countries including Australia and some wiring may still use these colours Load Also called Brown Black Red Active Line Hot Blue White Bla...

Страница 10: ... parts bag Figure 7 Remove safety cover 5 Remove the C14 connector from the additional unit 6 Cut and strip the power cord to the length required 7 Run the power cord through the cable support holder of the previous unit 8 Connect the power cord of the additional unit to the unused terminal block in the previous unit Note the embossed markings L earth symbol and N ...

Страница 11: ...h one screw 11 Replace the top cover 12 Fasten the power cord to the wall depending on local regulations 13 Repeat the same steps to install additional units Test Installation 1 When the fixed installation is completed apply AC power by switching on the disconnect de vice 2 Place a battery in the charging slot 3 A yellow LED indicates that charging starts while a green LED indicates a fully charge...

Страница 12: ...er supply 2 Place a battery in the charging slot to start charging Secure the battery by moving the lock switch Battery Disconnection 1 Unlock the lock switch on the battery 2 Remove the battery by lifting it Troubleshooting Fault Solution Charging does not start Check that the battery is properly inserted in the charger Check the AC power supply connection ...

Отзывы: