Alarm and Emergency Call Configuration, Administrator Documentation

0-3

  

  

  

For internal use only

Tables

Tables

0

Table 2-1

Function overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-1

Table 3-1

Parameter – General Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-5

Table 3-2

Parameter – Manual Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-6

Table 3-3

Parameter – Manual Alarm, example . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-7

Table 3-4

Parameter – Non Movement Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-8

Table 3-5

Parameter – Man Down Alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-8

Table 3-6

Parameter – Time Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-9

Table 3-7

Parameter – Escape Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-10

Table 3-8

Parameter – Pull Cord Alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-11

Table 3-9

Parameter – Prealarm/Alarming Signal. . . . . . . . . . . . . . . . . . . . . . . . . .   3-12

Table 3-10

Parameter – [Mode] Activation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-13

Table 3-11

Parameter – Control Ports in Basic Mode . . . . . . . . . . . . . . . . . . . . . . . .   3-14

Table 3-12

Parameter – Control Ports in Alarm/PNG Mode . . . . . . . . . . . . . . . . . . .   3-14

Table 3-13

Parameter – Techn. Warning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-15

Table 3-14

Parameter – Alarm Signal PIN  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-17

Table 3-15

Parameter – Emergency Call  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-18

Table 4-1

Phone number syntax – Calls to the alarm server  . . . . . . . . . . . . . . . . . .   4-1

Table 4-2

Phone number syntax – Calls from the alarm server  . . . . . . . . . . . . . . . .   4-2

Table 4-3

Phone number example  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4-2

Table 5-1

Response times under VDE 0825 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5-1

Table 6-1

Launching the Additional Features - Configuration - Basic Configuration menu 
6-1

Table 6-2

Additional Features - Configuration - Basic Configuration menu  . . . . . . .   6-1

Table 6-3

Additional Features - Configuration menu. . . . . . . . . . . . . . . . . . . . . . . . .   6-1

Table 6-4

Additional Features - Configuration - Basic Configuration - Alarms menu    6-2

Table 6-5

Launching the Additional Features - Configuration - Basic Configuration menu 
6-3

Table 6-6

Launching the Additional Features - Operating Mode menu. . . . . . . . . . .   6-3

Table 6-7

Additional Features - Configuration - Basic Configuration menu  . . . . . . .   6-3

Table 6-8

Additional Features - Configuration - Basic Configuration menu  . . . . . . .   6-4

Table 6-9

Additional Features - Configuration menu. . . . . . . . . . . . . . . . . . . . . . . . .   6-4

Table 6-10

Additional Features - Configuration - Basic Configuration - Alarms menu    6-5

Table 6-11

Additional Features - Configuration - Basic Configuration - Alarms menu    6-5

Table 6-12

Launching the Additional Features - Configuration - Alarm Configuration menu 
6-6

Table 6-13

Launching the Additional Features - Operating Mode menu. . . . . . . . . . .   6-6

Table 6-14

Additional Features - Configuration - Alarm Configuration menu . . . . . . .   6-6

Table 6-15

Additional Features - Configuration - Alarm Configuration menu . . . . . . .   6-7

Table 6-16

Additional Features - Configuration menu. . . . . . . . . . . . . . . . . . . . . . . . .   6-7

Table 6-17

Additional Features - Configuration - Alarm Configuration - Alarms menu  6-8

Содержание OpenStage M3 EX

Страница 1: ...OpenStage M3 M3 Plus OpenStage M3 Ex M3 Ex Plus on HiPath Cordless Alarm and Emergency Call Configuration Administrator Documentation A31003 M2000 M103 2 A9...

Страница 2: ...criptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products An obligation to provide...

Страница 3: ...1 3 1 2 Configuration 3 2 3 1 3 Operating mode OpenStage M3 Plus and OpenStage M3 Ex Plus only 3 2 3 1 4 Display Rotate OpenStage M3 Plus and OpenStage M3 Ex Plus only 3 3 3 2 Configuration menu 3 4...

Страница 4: ...nistrator Documentation SHB_PNG_TOC fm 6 Structure of the Additional Features menu 6 1 6 1 OpenStage M3 OpenStage M3 Ex 6 1 6 2 OpenStage M3 Plus OpenStage M3 Ex Plus 6 3 6 2 1 Operating Mode 1 Basic...

Страница 5: ...6 1 Launching the Additional Features Configuration Basic Configuration menu 6 1 Table 6 2 Additional Features Configuration Basic Configuration menu 6 1 Table 6 3 Additional Features Configuration me...

Страница 6: ...s Configuration PNG Configuration menu 6 9 Table 6 20 Launching the Additional Features Operating Mode menu 6 9 Table 6 21 Additional Features Configuration PNG Configuration menu 6 9 Table 6 22 Addit...

Страница 7: ...mergency call function The function range corresponds to that of Basic Mode An emergency call via an alarm key is possible regardless of selecting and activating an operating mode The PNG S monitors t...

Страница 8: ...ystem uses and processes personal data for example in the case of call detail recording display messages and customer data recording In Germany the processing and use of such data is subject to variou...

Страница 9: ...Emergency Call Configuration Administrator Documentation 1 3 Introduction Notational conventions and symbols used 1 3 Notational conventions and symbols used i identifies useful information 7 Safety...

Страница 10: ...ble between the different modes Contents This chapter covers the following topics Section 2 1 Mode dependent functions Section 2 2 Basic Mode Availability alarm and emergency call Section 2 3 Alarm Mo...

Страница 11: ...reach the alarm destination as reliably as possible the alarm calls are repeated until the configured number of retries has been reached or the alarm retry has been interrupted manually on the handse...

Страница 12: ...de Freely configurable monitoring PNG Mode should be used for BGR 139 compliant configuration All alarms can be freely configured in Alarm Mode of the OpenStage M3 Plus and OpenStage M3 Ex Plus handse...

Страница 13: ...ng is activated by the alarm server if the function test has been performed successfully Alarm calls from the PNG S are directed to the configured alarm destination To ensure that the alarm calls reac...

Страница 14: ...efore monitoring If individual workplaces are prohibited in the applicable regulations this ban may not be circumvented with a personal alarm device The handset has sent an alarm signal to the PNEZ an...

Страница 15: ...he alarm and signalling functions 3 1 1 Mode Activation Use this menu option to manually activate and deactivate the mode configured in the Configuration menu and selected in the Operating Mode menu D...

Страница 16: ...ion Access to the Configuration menu is blocked as long as one of the operating modes is active see Section 3 1 1 Mode Activation For more information on this menu please refer to Section 3 2 Configur...

Страница 17: ...Use this menu option to activate and deactivate the automatic position dependent rotation of the information on the display When activated the display is rotated by 180 upside down in non movement and...

Страница 18: ...ce PIN changed 3 2 1 Alarm Konfiguration 3 2 1 1 Alarms The following alarms are supported by the handset Manual Alarm Non Movement Alarm Man Down Alarm Time Alarm Escape Alarm Pull Cord Alarm 7 Use P...

Страница 19: ...r General Settings Parameters Operating Mode Value Range Standard Value Control Port Basic BM AM PNG up to 32 digits blank Alarm Destination BM AM PNG up to 32 digits blank Alarm Destination 1 BM up t...

Страница 20: ...tion 3 Enter the five position service PIN and confirm with OK 4 Select one of the three operating modes 5 Select Alarms 6 Select Manual Alarm 7 Change the values of the following parameters Table 3 2...

Страница 21: ...m can be activated optionally It is triggered if the sensors identify lack of movement over a defined configurable period of time For more information on alarm destinations please refer to Chapter 4 C...

Страница 22: ...figuration menu 8 Confirm with Save Man Down Alarm The Man Down Alarm can be activated optionally It is triggered if the sensors identify undue tilting of the handset over a defined configurable perio...

Страница 23: ...rvice PIN and confirm with OK 4 Select one of the three operating modes 5 Select Alarms 6 Select Time Alarm 7 Change the values of the following parameters Response Time BM AM 10 900 s 90 s PNG 10 90...

Страница 24: ...Select one of the three operating modes 5 Select Alarms 6 Select Escape Alarm 7 Change the values of the following parameters Table 3 7 Parameter Escape Alarm Parameters Operating Mode Value Range Sta...

Страница 25: ...r the five position service PIN and confirm with OK 4 Select one of the three operating modes 5 Select Alarms 6 Select Pull Cord Alarm 7 Change the values of the following parameters Table 3 8 Paramet...

Страница 26: ...realarm Alarm 5 Alarming Signal Alarm 1 Volume BM AM PNG 1 5 Prealarm 3 Alarming Signal 5 9 Confirm with Save 3 2 1 2 Mode Activation Specify here how the selected operating mode see Section 3 1 3 Ope...

Страница 27: ...performed The control ports are phone numbers of the alarm server that are used for signalling the states events between the handset and the alarm server The phone numbers of the control ports are en...

Страница 28: ...32 digits blank Alarm Recall loud up to 32 digits blank Alarm Recall quiet up to 32 digits blank Alarm Recall up to 32 digits blank 7 Confirm with Save 3 2 1 4 Techn Warning The DPS function is only s...

Страница 29: ...g Parameters Operating Mode Value Range Standard Value Activation BM AM PNG On off On DPS Request Time BM AM PNG 0 min 120 min 2 min Out of range time BM AM PNG 0 min 120 min 2 min Warning Signal BM A...

Страница 30: ...to the default values The factory set default values can be referenced in the respective configuration description Standardwert Default Value column Procedure 1 Select the Additional Features icon in...

Страница 31: ...d third emergency call alarm number when the handset has registered on the HiPath 3000 OpenScape Business or HiPath OpenScape 4000 All other systems only support a dialing of one emergency call or ala...

Страница 32: ...w the alarm destination to be reached If necessary perform test calls SHB_PNG Konfig fm A31003 M2000 M103 2 76A9 07 2014 Alarm and Emergency Call Configuration Administrator Documentation 3 18 Configu...

Страница 33: ...d confirm with OK 4 Select Emergency Call 5 Select Reset to default and confirm with YES 3 2 3 Service PIN The service PIN is required for accessing the Configuration and Operating Mode menus 7 Make s...

Страница 34: ...lect the Additional Features icon in the main menu 2 Select Configuration 3 Enter the five position service PIN and confirm with OK 4 Select Service PIN 5 Enter an individual five position PIN repeat...

Страница 35: ...on Administrator Documentation SHB_PNG Konfig fm Exporting and transmitting the configuration 3 3 Exporting and transmitting the configuration The tool is available on the SWS The Firmware Update Tool...

Страница 36: ...M3 and OpenStage M3 Ex handsets see Section 3 2 1 3 Control Ports in Basic Mode Alarm destinations that are monitored by the server are not available The appropriate control ports and destination num...

Страница 37: ...QUERKZ NWKZ 8 Alarm Recall QUERKZ NWKZ 9 4 2 Example Sample values QUERKZ 664 NWKZ 72 Please consult your HiPath technician for the actual values provided Escape Alarm QUERKZ NWKZ 0 5 Pull Cord Alarm...

Страница 38: ...be generated automatically Manual Alarm SP 664 72 0 1 Will be generated automatically Non Movement Alarm 664 72 0 2 Will be generated automatically Man Down Alarm 664 72 0 3 Will be generated automat...

Страница 39: ...Type Response Time PNA PNA S Manual personal alarm 2 s 30 s for voice traffic otherwise 2 s Prealarm 15 s 15 s Automatic personal alarm including prealarm Man Down Alarm 90 s 90 s Non Movement Alarm 9...

Страница 40: ...ce PIN Emergency Call Control Ports 00000 Service PIN Techn Warning Reset to default Table 6 2 Additional Features Configuration Basic Configuration menu BM Activation Control Ports Techn Warning Rese...

Страница 41: ...1 5 Table 6 4 Additional Features Configuration Basic Configuration Alarms menu General Settings Non Movement Alarm Man Down Alarm Time Alarm Autom Alarm Activation Activation Activation On Off On Off...

Страница 42: ...ay Rotate Emergency Call Techn Warning Service PIN Adjust Sensor Reset to default Table 6 6 Launching the Additional Features Operating Mode menu Additional Features Service PIN Operating Mode BM Acti...

Страница 43: ...t in to vertical position default Back OK No Yes Table 6 9 Additional Features Configuration menu Emergency Call Service PIN Emergency Nr 1 Change PIN 112 Please enter Emergency Nr 2 Service PIN Emerg...

Страница 44: ...Audio Channel Handsfr Handset Table 6 11 Additional Features Configuration Basic Configuration Alarms menu Escape Alarm Pull Cord Alarm Alarm Signal Activation Activation Prealarm On Off On Off Warni...

Страница 45: ...fault Alarm Signal PIN Table 6 13 Launching the Additional Features Operating Mode menu Additional Features Service PIN Operating Mode BM Activation Please enter 1 Basic Mode Configuration Service PIN...

Страница 46: ...n to PIN On Off vertical position default Please enter Back OK No Yes Alarm Signal PIN 11111 Emergency Call Service PIN Emergency Nr 1 Change PIN 112 Please enter Emergency Nr 2 Service PIN Emergency...

Страница 47: ...ec 15sec 0 300 sec Autom Alarm Shortpress On Off Alarm Destination Alarm Destination On Off Longpress On Off Off in Alarm Destination Charger Shortpress Audio Channel Longpress Handsfr Handset Time Al...

Страница 48: ...ault Alarm Signal PIN Table 6 20 Launching the Additional Features Operating Mode menu Additional Features Service PIN Operating Mode PNG Activation Please enter 1 Basic Mode Configuration Service PIN...

Страница 49: ...enu Adjust Sensor Reset to default Alarm Signal PIN Please adjust Reset Base Settings Alarm Signal PIN handset in to PIN On Off vertical position default Please enter Back OK No Yes Alarm Signal PIN 1...

Страница 50: ...ponse Time Alarm Key locked 90sec 10 90 sec 90sec 10 90 sec Alarm Call Count On Off Prealarm Prealarm 99 2 99 Alarm Signal 15sec 0 30 sec 15sec 0 30 sec Autom Alarm Shortpress On Off Alarm Destination...

Страница 51: ...Plus OpenStage M3 Ex Plus 15sec 0 15 sec 15sec 0 15 sec 15sec 0 15 sec Volume 3 1 5 Alarm Destination Sensitivity Level Alarm Destination Alarming Signal Low Medium High Alarm Signal Alarm Destinatio...

Страница 52: ...ion DECT Digital Enhanced Cordless Telecommunications DPS DECT Positioning System HNA HiPath Notsignal Anlage HiPath alarm system NOK Not OK PNA Personen Notsignal Anlage personal alarm system HNA HiP...

Страница 53: ...s 3 13 Conventions 1 3 D Display Rotate 3 3 E Emergency Call 3 17 Escape Alarm 1 1 3 10 G General Settings 3 4 H HiPath PNA personal alarm system 2 3 M Man Down Alarm 1 1 3 8 Manual Alarm 1 1 3 6 N No...