4. After all settings have been made, confirm the settings by clicking on Save Settings.
4.
5. The rebooting process of the microMIND V2 takes a few seconds.
5.
Code Conversion
The Code Conversion functionality lets you convert the read ID into a number of other
notations, e.g. you read out an ID in hexadecimal, but you need it in decimal, or you
need the read ID in a reverse order etc. For such cases, a code conversion option is
available in the uniFLOW Server Configuration. It has been implemented, primarily to
support a Code Conversion for microMIND. However, the Code Conversion can be set to
a "Global Code Conversion" for all ID devices or to microMINDs only.
The configuration is done on the in uniFLOW Server Configuration > Server Config. >
General Settings > General > Code Conversion.
Parameters
▪ Code Conversion Script:
▪
Here you can enter the desired Code Conversion rules. The supported commands are
the following:
◦
HexToBinary
◦
◦
DecimalToBinary
◦
◦
BinaryToHex
◦
◦
BinaryToDecimal
◦
◦
HexToDecimal
◦
◦
DecimalToHex
◦
◦
RemoveLeadingZeros
◦
8
Configuration
5.1.1