Technical data 

design 

PKM 02 

display        

2x pointer instrument 0-130% drag indicator 

operating system       

2x potentiometer 0-100% 2x reset-/2x testbutton 

power supply 

24V DC 

power consumption 

ca. 150W 

temperature range          

0-60°C 

humidity    

max. 95% non condensing 

input impedance amplifier 

1013 Ω

 

output signal analog 

47 Ω / 0

-10V DC via M12 socket 5pin 

output signal digital 

NC contact max. 250V AC/1A 

dimensions (WxHxD) 

264.5x175.14x59.0mm 

weight 

ca. 2.3 kg 

 
 

5

 

Introduction 

The PKM 2000 is an analog press force measuring device with 2 channels. 
The control and monitoring components installed in the device have been designed according to 
state-of-the-art technology. The extension and compression of the press is measured by the piezo 
sensors. The piezo sensors then convert the extension (compression), proportional to the force, 
into an electric voltage. The maximum force occuring in any one cycle is saved to memory and 
displayed and compared to the set value. If the set values are exceeded, the press is automatically 
switched off. The values can be set to up to 130% of the press load as the tools often have an 
asymmetric force distribution. 
 

Please note: 100% for each side of the press is equal to 50% of the overall tonnage. 

 

Содержание PKM 02

Страница 1: ...ensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 PKM 02 TRsystems GmbH D 75179 Pforzheim Freiburger Stra e 3 Phone 49 0 7231 31520 Fax 49 0 7231 315299 info unidor de www un...

Страница 2: ...w Third party applications of this manual which violate copyright provisions are prohibited Reproduction translation and electronic and photographic archiving and alteration require written consent of...

Страница 3: ...3 3 Organizational measures 6 4 Technical data 7 5 Introduction 7 6 Signals and connection diagram 8 7 View of the device 8 7 1 Front of the device 8 7 2 Back of the device 9 8 Programming the cutoff...

Страница 4: ...Page 4 of 19 user manual Practice user manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 1 Change index Change Date Index First edition 13 june 23 00...

Страница 5: ...ecifications or it may be requested separately These operating instructions are kept up to date However since TRsystems GmbH UNIDOR products are subject to continuous further development it is possibl...

Страница 6: ...as CPF2 2 Communication Profile The technical directives on establishing the Ethernet network must be complied with in order to ensure safe operation The intended use also includes observing all notes...

Страница 7: ...3 kg 5 Introduction The PKM 2000 is an analog press force measuring device with 2 channels The control and monitoring components installed in the device have been designed according to state of the a...

Страница 8: ...sensors Outputs and power supply PKM 02 M12 socket X01 machine stop The relay is linked to the stop circuit of the machine linked This stops the machine immediately in the event of an error Analog ou...

Страница 9: ...manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 7 2 Back of the device X75 2 sensor input channel 2 X75 1sensor input channel 1 X74 analog output...

Страница 10: ...ach side will automatically be switched off if a press force of 200 kN is reached The value last recorded is saved for several seconds and can be read off the instruments 8 1 Resetting faults By press...

Страница 11: ...ing of comparator stage channel 2 factory settings jumper ME1 setting jumper ME2 setting jumper ME3 setting SW402 SW401 SW202 SW201 ME1 ME2 ME3 P302 P102 SW1 P1 P4 P302 trimmpoti channel 2 P302 trimmp...

Страница 12: ...Tel 49 0 7231 3152 0 8 3 1 View of the board 8 4 Connections and settings on the board To adjust the capacitance and gain the rear cover of the device must be removed be removed Warning Before openin...

Страница 13: ...de switches setting not permitted Codeswitches SW201 401 capacity nF 0 71 8 1 65 0 2 61 8 3 55 0 4 49 8 5 43 0 6 39 8 7 33 0 8 38 8 9 32 0 A 28 8 B 22 0 C 16 8 D 10 0 E 6 8 F 0 0 Codeswitches SW202 40...

Страница 14: ...imit 1KHz 33nF default 1 2 OFF 1 F limit 100Hz 220nF II 33nF 1 ON 2 OFF 2 F limit 355Hz 47nF II 33nF 2 ON 1 OFF either turn on only 3 or 4 or turn on none 3 with filter default 3 ON 4 OFF 4 without fi...

Страница 15: ...ther on the pressing or drawing side see diagram below In order to protect the sensors please place the protective caps over the sensors once the latter have been mounted and calibrated The cables tha...

Страница 16: ...SW402 set the maximum performance of the object to be measured e g max press force keep pressing the code switch SW201 SW401 until the required output voltage is shown on the display max 10 V using t...

Страница 17: ...Page 17 of 19 user manual Practice user manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 9 Dimensions...

Страница 18: ...Page 18 of 19 user manual Practice user manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0...

Страница 19: ...rzheim hereby confirm for the Product PKM 02 Device type Press Force Measuring Device Model name PKM 02 compliance with the EC Directive 89 392 EEC and the following standards EN 60204 1 Electrical Eq...

Отзывы: