Programming the cutoff values 

Turn the setting dial "max. press force" to the press force you require. 
Example: If you set the dial to 40%, a press with 1000 kN - i.e. 500 kN for each side - will 
automatically be switched off if a press force of >200 kN is reached. The value last recorded is 
saved for several seconds and can be read off the instruments. 

8.1

 

Resetting faults 

By pressing the RESET button or over X74 the fault will be reset. The display shows 0% again. 
The device is ready for operation. 

8.2

 

Test 

By pressing the TEST button, the 100% display can be checked. If the limit values on the setting 
dials are set to <100%, the output relay cuts off. (Checking the cutoff function). 

8.3

 

Block diagram 

 

 

 

 

 

 

Содержание PKM 02

Страница 1: ...ensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 PKM 02 TRsystems GmbH D 75179 Pforzheim Freiburger Stra e 3 Phone 49 0 7231 31520 Fax 49 0 7231 315299 info unidor de www un...

Страница 2: ...w Third party applications of this manual which violate copyright provisions are prohibited Reproduction translation and electronic and photographic archiving and alteration require written consent of...

Страница 3: ...3 3 Organizational measures 6 4 Technical data 7 5 Introduction 7 6 Signals and connection diagram 8 7 View of the device 8 7 1 Front of the device 8 7 2 Back of the device 9 8 Programming the cutoff...

Страница 4: ...Page 4 of 19 user manual Practice user manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 1 Change index Change Date Index First edition 13 june 23 00...

Страница 5: ...ecifications or it may be requested separately These operating instructions are kept up to date However since TRsystems GmbH UNIDOR products are subject to continuous further development it is possibl...

Страница 6: ...as CPF2 2 Communication Profile The technical directives on establishing the Ethernet network must be complied with in order to ensure safe operation The intended use also includes observing all notes...

Страница 7: ...3 kg 5 Introduction The PKM 2000 is an analog press force measuring device with 2 channels The control and monitoring components installed in the device have been designed according to state of the a...

Страница 8: ...sensors Outputs and power supply PKM 02 M12 socket X01 machine stop The relay is linked to the stop circuit of the machine linked This stops the machine immediately in the event of an error Analog ou...

Страница 9: ...manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 7 2 Back of the device X75 2 sensor input channel 2 X75 1sensor input channel 1 X74 analog output...

Страница 10: ...ach side will automatically be switched off if a press force of 200 kN is reached The value last recorded is saved for several seconds and can be read off the instruments 8 1 Resetting faults By press...

Страница 11: ...ing of comparator stage channel 2 factory settings jumper ME1 setting jumper ME2 setting jumper ME3 setting SW402 SW401 SW202 SW201 ME1 ME2 ME3 P302 P102 SW1 P1 P4 P302 trimmpoti channel 2 P302 trimmp...

Страница 12: ...Tel 49 0 7231 3152 0 8 3 1 View of the board 8 4 Connections and settings on the board To adjust the capacitance and gain the rear cover of the device must be removed be removed Warning Before openin...

Страница 13: ...de switches setting not permitted Codeswitches SW201 401 capacity nF 0 71 8 1 65 0 2 61 8 3 55 0 4 49 8 5 43 0 6 39 8 7 33 0 8 38 8 9 32 0 A 28 8 B 22 0 C 16 8 D 10 0 E 6 8 F 0 0 Codeswitches SW202 40...

Страница 14: ...imit 1KHz 33nF default 1 2 OFF 1 F limit 100Hz 220nF II 33nF 1 ON 2 OFF 2 F limit 355Hz 47nF II 33nF 2 ON 1 OFF either turn on only 3 or 4 or turn on none 3 with filter default 3 ON 4 OFF 4 without fi...

Страница 15: ...ther on the pressing or drawing side see diagram below In order to protect the sensors please place the protective caps over the sensors once the latter have been mounted and calibrated The cables tha...

Страница 16: ...SW402 set the maximum performance of the object to be measured e g max press force keep pressing the code switch SW201 SW401 until the required output voltage is shown on the display max 10 V using t...

Страница 17: ...Page 17 of 19 user manual Practice user manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0 9 Dimensions...

Страница 18: ...Page 18 of 19 user manual Practice user manual Systems Controls Sensors by TRsystems GmbH 75179 Pforzheim www unidor de Tel 49 0 7231 3152 0...

Страница 19: ...rzheim hereby confirm for the Product PKM 02 Device type Press Force Measuring Device Model name PKM 02 compliance with the EC Directive 89 392 EEC and the following standards EN 60204 1 Electrical Eq...

Отзывы: