Programming the cutoff values
Turn the setting dial "max. press force" to the press force you require.
Example: If you set the dial to 40%, a press with 1000 kN - i.e. 500 kN for each side - will
automatically be switched off if a press force of >200 kN is reached. The value last recorded is
saved for several seconds and can be read off the instruments.
8.1
Resetting faults
By pressing the RESET button or over X74 the fault will be reset. The display shows 0% again.
The device is ready for operation.
8.2
Test
By pressing the TEST button, the 100% display can be checked. If the limit values on the setting
dials are set to <100%, the output relay cuts off. (Checking the cutoff function).
8.3