Initiation
•
wire up the sensors and connecting cables
•
connect the distribution voltage
•
connect the press stop output to the press control
•
set the amplifier to basic position 3 using the code switch SW202 (SW402)
•
set the maximum performance of the object to be measured (e.g. max. press force)
•
keep pressing the code switch SW201 (SW401) until the required output voltage is shown on
the display (max. 10 V)
•
using the code switch SW202 (SW402) you are also able to compensate the differing sensitivity
of the sensors, for those devices with several channels
•
if the board is replaced (service), please ensure that the code switches are set to the same
values as before, otherwise there could be a danger of overloading. It may also be necessary to
recalibrate the device.