6.
Connection of the Piezo Sensors
Sensor JZT127/S with black connection cable for rack mounting
Terminal assignment for pressure load
Sensors
Connector LVCpro-S
Core Colour
PIN
Press Force Sensor
1
PiezoSensor 1
black
red
Shield
IN1
GND
CASE
Press Force Sensor
2
PiezoSensor 2
black
red
Shield
IN2
GND
CASE
Terminal assignment for tensile load
Sensors
Connector LVCpro-S
Core Colour
PIN
Press Force Sensor
1
Piezosensor 1
red
black
Shield
IN1
GND
CASE
Press Force Sensor
2
Piezosensor 2
red
black
Shield
IN2
GND
CASE
Sensor JZT127/P with white connection cable for rod mounting
Terminal assignment for pressure load
Sensors
Connector LVCpro-S
Connector
PIN
Press Force Sensor
1
Piezosensor 1
black
white
Shield
IN1
GND
CASE
Press Force Sensor
2
Piezosensor 2
black
white
Shield
IN2
GND
CASE
Terminal assignment for tensile load
Sensors
Core Colour
Connector
PIN
Press Force Sensor
1
Piezosensor 1
white
black
Shield
IN1
GND
CASE
Press Force Sensor
2
Piezosensor 1
white
black
Shield
IN2
GND
CASE