Alignment of FM PCB
Test Equipm ent Required
DC Power Supply (DC 8V)
FM SG 450KHz
Oscilloscope
AC Voltmeter 2
Oscillator
DC Voltmeter
2. Alignm ent Procedure
PA : OFF
Step
Preset to
Adjustm ent
Remarks
1
RX
FM SG : 3mV out
1kHz, ± 15kHz
dev.
L601
Connect a DC Voltm eter to between TP601 and GND.
Adjust 1601 for 4.5 ± 0.1V reading on the DC Voltmeter.
Check if voltage value is 150—350 mV.
2
TX
Osc : 10mV
1kHz
VR601
m iddle
position
Adjust VR601 fo r 4—9 mV reading on the A C Voltmeter.
1