Your camera is set to a baud rate of 2400. This will allow you to effectively control the camera up to 3,000 feet away.
Areas with electronic interference may require heavier or shielded cabling. Also, the higher the setting, the shorter the distance
control which may be required for some PTZ controllers.
EXAMPLE
Image A displays the following camera settings:
Address = Channel 1
Baud Rate = 2400
Pelco-D Communication Protocol
SETTING PROTOCOL
NOTE!
Some PTZ controllers may require specific connection speeds. Check your system’s manual for the
proper settings.
SETTING CAMERA ADDRESS
1
1 0 0 0 0 0
2
0 1 0 0 0 0
3
1 1 0 0 0 0
4
0 0 1 0 0 0
5
1 0 1 0 0 0
6
0 1 1 0 0 0
7
1 1 1 0 0 0
8
0 1 0 0 1 0 0
9
1 0 0 1 0 0
10
0 1 0 1 0 0
11
1 1 0 1 0 0
12
0 0 1 1 0 0
13
1 0 1 1 0 0
14
0 1 1 1 0 0
15
1 1 1 1 0 0
16
0 0 0 0 1 0
Address switch
Address (8 digits)
CODE
1 2 3 4 5 6
SETTING BAUD RATE
7
8
1200bps
1
1
2400bps
0
1
4800bps
1
0
9600bps
0
0
Baud Rate
Switch Number (BIT)
Pelco-D
1
Pelco-P
0
Protocol
Switch
Number 9
1 2 3 4 5 6 7 8 9 10
ON
Baud
Rate
Comm
Protocol
N/A
Camera Address
Image A