Manual – Starflow QSD Model 6527B and 6537A
Unidata Manual - 6527B and 6537A Starflow QSD User Manual 17 01 2020.docx
Page 1
1.0 INTRODUCTION
The 1
st
generation 6527 Starflow QSD Instrument measures water Velocity, Depth (ultrasonic) and
Temperature. The Starflow QSD – 2
nd
generation has been enhanced to include Depth using the
Pressure – Hydrostatic method (6527B Starflow QSD) and Electrical Conductivity (6537A Starflow
QSD) as well as Tilt. These models come standard with both SDI-12 and RS-485 (Modbus RTU)
interfaces.
The capacity of the instrument to measure the water conductivity is unique and allows the instrument
to determine not only the water velocity, flow and volume but also an indication of the water quality.
The conductivity measurement can also be used where existing techniques for measuring water
quality are unsuitable or too expensive.
By using Digital Signal Processing (DSP) techniques, the Starflow QSD is able to perform in a wide
range of environments. It is used to measure flows and water conductivity (6537A) in pipes, channels
and small streams. It can operate in a range of water qualities from fresh streams to primary sewage
channels.
Electrical conductivity feature of 6537A instrument empower the user to detect unusual waste
dumping / agriculture runoff which is not visible using current flow sensors. The pressure depth
sensor allow the instrument to be placed in an angled position on the wall of irregularly shaped
drainage canals or on the sides of channels in which is difficult or impossible to place it on the
channel floor.
The Tilt parameter is measured by an internal accelerometer and represents the pitch and roll of the
instrument body as it is installed and its measurement is in degrees angle. This provides user with
useful information of the sensor after mounted under water or during a post installation inspection.
Starflow QSD system consists of:
Model 6527B or 6537A Starflow QSD instrument
Model 6527M Stainless Steel Mounting Bracket
6527B
6537A