background image

User and installation manual  

 

Réf : 004057-02

 

 

Page : 15/17 

In this case please verify sensor connections on terminal block. 
If alarm persists even disconnecting completely sensor cable, please contact our service team. 

4.4  Fuse fault 

INFO/ALARM display will show «   » fix. 

Verify pool cover status and cabling before restarting the motor. In case of defect, change motor fuse 

 

4.5  Important Archimede force 

INFO/ALARM display will show « 

 » blinking. 

This alarm is risen just for information.   

4.6  Excessive Archimede force 

INFO/ALARM display will show « 

 » fix. 

This alarm is risen just for information.   

4.7  Software defect 

INFO/ALARM display will show « 

 » fix. 

In this case switch off completely the control board, wait 5 seconds and power it up again. If alarm persists contact 
our service team 

4.8  Electronic board defect 

INFO/ALARM display will show « 

 » blinking. 

This alarm informs about a major hardware problem on the board. Motor activation is inhibited. Please send back the 
board for analysis and eventual repair. 

4.9  Power feed defect 

INFO/ALARM display will show « 

 » fix. 

In this case switch off completely the control board, wait 5 seconds and power it up again. If alarm persists contact 
our service team. 

 

 

Motor fuse 

Содержание AN1244

Страница 1: ...www unicum tech User and Installation Manual KEEP THIS MANUAL FOR FUTURE REFERENCE DATE VERSION MODIFICATIONS 08 2020 01 AN1244A AN1274A 05 2021 02 Modifications alarms SWx WARNING Basic safety rules...

Страница 2: ...be performed by a qualified and authorized technician who has been trained to swimming pool equipment installation Before installing this product please read the whole user manual and follow all instr...

Страница 3: ...from sensors Auxiliary Relay for electrolyser or pump management One digit display for alarm notification and troubleshooting FUSES CARACHTERISTICS AN1244 F1 Fuse ATO 10A F2 Fuse 5x20 3 15A Time lag A...

Страница 4: ...weight of the control box Control box positioning and drilling 1 Mark on the wall the four positions corresponding to the four external holes in the corners of the box you can use the drilling positi...

Страница 5: ...ection identification on the key switch Positions and rotation directions must be clearly identified on the key switch and must remain understand all along cover pool lifetime Fig 3 Example of identif...

Страница 6: ...green cable can be used only for ground connection Do not forget to screw cable glands when wiring is done this guarantees correct waterproof level WARNING All electrical connections have to be made...

Страница 7: ...e3 For TT operating conditions the circuit must be protected upstream by a bipolar differential circuit breaker with a sensitivity of 30 mA 6 A intensity and a type C trigger curve Use a cable H07 VV...

Страница 8: ...mmon COM and contacts normally closed NC normally open NO Mode Pool cover position Etat du relais Led AUX Automatic Completely open NO Moving NC Completely closed NC Manual Depending on motor rotation...

Страница 9: ...chapter 3 6 and verify that motor rotation sensor is coherent with three position key switch settings ATTENTION in FORCED mode sensor signal is not taken into account it is therefore possible to move...

Страница 10: ...ntrol box has been conceived and sized in order to work continuously up to 10 minutes maximum Beyond this time try to let the board at rest for half an hour to allow components cooling down Temperatur...

Страница 11: ...mit switch programming to be done Fix Unused Blinking Unused Fix Safety loop open Blinking Sensor defect Fix Sensor power supply problem Blinking Unused Fix Fuse F1 to be replaced Blinking Important A...

Страница 12: ...r eyes and survey while moving the cover This mode allows a normal usage of the cover with automatic stop when limit switch is reached In this mode cover can be controlled by different devices key swi...

Страница 13: ...tting is OFF micro switch 1 on SW1 set to OFF corresponding to hold mode for close device This function is inactive when control box is in MANUAL or PROGRAMMATION even if the dip switch is set to ON M...

Страница 14: ...ctivated with micro switch 3 on SW1 External device has to be equipped with a contact normally closed which opens in case of abnormal condition thus blocking the motor In this case INFO ALARM display...

Страница 15: ...mede force INFO ALARM display will show fix This alarm is risen just for information 4 7 Software defect INFO ALARM display will show fix In this case switch off completely the control board wait 5 se...

Страница 16: ...y safe way 5 1 Maintenance Control box doesn t need special maintenance User is invited to check periodically the status of control devices especially for remotes Replace any control device when they...

Страница 17: ...r normal usage corresponding to a maximum continuous usage of 10 minutes Beyond this time please wait half an hour for cooling board components Warranty is not applicable in the following cases Replac...

Отзывы: