Motor:
Use for connection one cable 2 wires type HO7 RN-F, 4 mm² section (minimum) and up to 10mm² depending on the
distance between motor and control box.
Motor cable colours: red and grey wires.
To be connected to MOTOR terminal block (positions 1 et 2)
Pass the cable through a cable gland.
Cabling verification:
Press button « MANU » to enter in FORCED mode (see chapter 3.6) and verify
that motor rotation sensor is coherent with three position key switch settings.
ATTENTION: in FORCED mode sensor signal is not taken into account; it is
therefore possible to move the cover even outside its normal working range thus
damaging the cover. Please use this mode with a lot of caution and always
keeping eyes and direct control on the pool.
In case cover moves in the wrong direction and if contact switch is correctly cabled, reverse grey and
red motor wire connections.
Emergency stop
Water level sensor
When opening, O/O green led blinks.
When closing, F/C green led blinks.