- 26 -
(1) Set the stitch length adjusting dial to the position "5".
(2) Loosen the screws①(H710-1×2, H710-2×4), and turn the rotary hook② so that its tip meets the
center of the needle when the needle is 2.4㎜ above the lowest position.
(3) After adjusting, tighten the screws①.
☞
Needle height
(1) Loosen the screw③, and raise or lower the needle bar so that the clearance between the upper end
of the needle eye and the rotary hook point will be 1~1.5㎜ when the rotary hook point meets the
center of the needle.
2. 가마와 오프너의 간격 조정법
ADJUSTING THE CLEARANCE BETWEEN ROTARY HOOK & BOBBIN CASE OPENER
☞
가마A부와 보빈케이스 오프너의 간격조정은
간격이 약0.2㎜가 되도록 나사를 풀고, 오프너를
좌우로 움직여 가면서 조정하십시오.
☞
Adjust the clearance between the rotary
hook A part and the bobbin case opener to about
0.2㎜ by loosening the screw and moving the bobbin
case opener to the right or left.