Failure (red)
Activated in case of discharge of
AB
or setting of
ABC
to alarm mode (refer to
Table 4).
10.
Menu structure and adjustment OF ABC
10.1
Menu structure
Menu structure of automatic battery charger CH-105 is the following:
I
[0,2..16]
Charging
current
[0/1]
[9..30]
Charging
voltage
Operating
mode
U
r
MENU
[0,2..20] -CH -105
[0,2..14] – for CH -105-220VDC
[0,2..16] – for CH -105-110VDC
[0,2..12] – for CH -105-2412А
[0,2..16] – for CH -105-24
Figure 10 ABC menu structure
Table 7 Description of ABC menu items
Menu item
Description
I
Selection of
AB
charging current (varies within 0.2–16
А
)
U
Selection of
AB
charging voltage (varies within 9–30 V)
R
Activation of
AB
function of protection from deep discharge
(enable – 1 / disable – 0)
Before setting the charging current and voltage study Paras 12 and 13 of this Operating
Manual.
10.2
ABC adjustment
10.2.1.
Setting of Charging Current
Charging current is set by the user by means of built-in keypad of the battery charger.
To set the required value of current, proceed as follows:
Press the key "SELECT" of
ABC
until character "I" appears on the left indicator of
the device. At the same time the earlier set charging current will be displayed on the right
indicator of the device
Use keys ▲ and ▼ to set the required charging current value
Press key "SET" to confirm the set value and record it in non-volatile memory of the
device.