background image

Date

Ref

Owner Name
Contact Details
Phone
AC System Type

Compressor Model

Clutch Type

Clutch Voltage

Refrigerant

Purity
Oil Type

Discharge Pressure

Suct.Pressure at Evap

Duct Temp - In 

oC 

Condensor Temp

oC  Suct.Pressure at Comp

Duct Temp - Out

oC 

Discharge Temp

oC  Pressure Drop

Temp Difference

oC 

Compressor Details

System Information

%

Oil Separator Fitted                     Yes / No
Accumulator Fitted                      Yes / No

Date Purchased



Vehicle Details

Invoice Number

Date Installed
Vehicle Type

  R12 / R134a / Other

UV Dye Added                            Yes / No

Operation Analysis at  1200 / 1500 / 1800  RPM (Indicate which)

Discharge

Suction

Other

Discharge Temp

oC  Pressure Drop

Temp Difference

oC 

Liquid Line Temp

oC  Suct.LineTemp at Comp

oC 

Discharge Superheat

oC  Evap Temp

oC  Condensor

m/s

Subcooling

oC  Suct.LineTemp at Evap

oC  Evap Duct - Front

m/s

Suct.Line Superheat

oC  Evap Duct - Rear

m/s

Discharge Pressure

Suct.Pressure at Evap

Duct Temp - In 

oC 

Condensor Temp

oC  Suct.Pressure at Comp

Duct Temp - Out

oC 

Discharge Temp

oC  Pressure Drop

Temp Difference

oC 

Liquid Line Temp

oC  Suct.LineTemp at Comp

oC 

Discharge Superheat

oC  Evap Temp

oC  Condensor

m/s

Subcooling

oC  Suct.LineTemp at Evap

oC  Evap Duct - Front

m/s

Suct.Line Superheat

oC  Evap Duct - Rear

m/s

Discharge Pressure

Suct.Pressure at Evap

Duct Temp - In 

oC 

Condensor Temp

oC  Suct.Pressure at Comp

Duct Temp - Out

oC 

Discharge Temp

oC  Pressure Drop

Temp Difference

oC 

Liquid Line Temp

oC  Suct.LineTemp at Comp

oC 

Discharge Superheat

oC  Evap Temp

oC  Condensor

m/s

Subcooling

oC  Suct.LineTemp at Evap

oC  Evap Duct - Front

m/s

Suct.Line Superheat

oC  Evap Duct - Rear

m/s

Ambient Temp

oC Clutch Cycle (set point)

oC Comp oil Level

cc

Airflows

Operation Analysis at  2000 / 2200 / 2400  RPM (Indicate which)

Airflows

Operation Analysis at  2500 / 3000 / 3600  RPM (Indicate which)

Airflows

Other Information

Note: measure compressor oil level by sight glass for models 330, 440 & 550.

To determine the performance of a Unicla UWX compressor in a specific application, the following 
Compressor Operation Analysis Report will assist in the collection of the necessary data.

15. Compressor Operation Analysis Report

10.

Содержание UWX440

Страница 1: ...UWX550 and UWX440 Installation Guidelines...

Страница 2: ...ining professional information using representative graphs charts and tables Manufacturers specifications must be consulted for specific guidelines and performance data Unicla published data specific...

Страница 3: ...and screen 7 12 Oil injector 8 13 Discharge line analysis pressure and temperature 8 14 Refrigerantcharging 9 15 Compressor operation analysis report 10 Note This booklet is designed to assist the ins...

Страница 4: ...solid particle and chemical contamination before compressor fitting Solid particle contamination will cause direct compressor damage and starvation due to blocked system filters and screens see sectio...

Страница 5: ...the bolt then pull out Fig A Fig B Fig C 3 Fitting of discharge hose manifold Install the gasket Install Manifold Valve this is right hand view M10 x L60 Bolt Tightening tension 34 3 Nm 355 kg cm Con...

Страница 6: ...nd this amount is excluded from the quantities recommend above Note Oil quantity calculations are contained in the Unicla Service Handbook Total system oil requirement is based on 20 and 30 of refrige...

Страница 7: ...rvation of the compressor Warranty is void if these guidelines are not followed Unicla Oil Type Alternative Unidap 6 POE 68 Unidap 7 PAG 46 Recommended alternatives for Unicla Lubricant 6 Oil type and...

Страница 8: ...point Oil Green colouration exposure to copper oxidation Operation OK Recommendation Monitor oil condition and change if necessary Sight Glass Oil level low half point Oil Normal clean and transparen...

Страница 9: ...e Unicla inline mesh screen and filter insert should be used whenever there is risk of debris and fine particles entering the compressor through the suction line In the case of older systems where the...

Страница 10: ...ual is required or reference to additional technical information for specifications and faults regarding condensing to air differentials NR not recommended as a continuous running phase superheat may...

Страница 11: ...peration b If it is not possible to access the system at the evaporator or roof level then service points in suction and discharge lines away from the compressor are the next best option c If refriger...

Страница 12: ...ut oC Discharge Temp oC Pressure Drop Temp Difference oC Liquid Line Temp oC Suct LineTemp at Comp oC Discharge Superheat oC Evap Temp oC Condensor m s Subcooling oC Suct LineTemp at Evap oC Evap Duct...

Страница 13: ...Notes...

Страница 14: ...Unicla International Limited Unit 1209 1210 12F Manhattan Centre 8 Kwai Cheong Rd Kwai Chung N T Hong Kong Phone 852 2422 0180 Fax 852 2422 0680 Email sales unicla hk Website www unicla hk...

Отзывы: