2.3 - SMOKE TURBOLATOR
XC-K oil boilers are designed to be used within an output range
in order to improve seasonal efficiency and coupling with each
heating system.
The heat output must therefore be adjusted upon commissioning,
based on the guidelines of the Thermotechnical Engineer, and
always within the range provided for each boiler on pages 14 - 15
by the burner technician who will determine the fuel flow rate.
In all cases,
the turbulators will be placed, within their smoke pipes with
respect to the front edge, as per below drawing.
Using the boiler to minimum power, the flue gas temperature
fig. 1a
must not be less than those indicated on page 14 and 15.
Otherwise, first contact our After Sales Service, make sure that
all the turbolators are present in smoke pipes.
At the first commissioning the burner must be carried out under
the responsibility of a qualified burner technician, authorized by
the burner manufacturer.
In that occasion must be compiled a complete working report.